'''How to realize X arm GR/IR alignment(from IMMT2(SR3) to ETMXY)'''

 1. Enter '''Alignment Mode1'''

 * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
 * Select "LSC_Lock" in Commissioning.Doc.
 * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.MAIN.png|LSC_Lock]].
 * Select "DOWN" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.STATES.png|All]].

# '''Enter Alignment Mode2'''

 * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
 * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
 * Select "! engage" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].

 # arm GR alignment (ITMY misalign).
 X arm GR alignment (Resonate GR).
 X arm GR alignment (Check spot position).
 X arm GR alignment (PR3 Dithering).
 X arm GR alignment (find good FP axis & PR3 P/Y).
 X arm FP axis is established and PR3 P/Y is fixed.
X arm GR alignment (Record good TMSX).
X arm IR alignment (Resonate IR).
X arm IR alignment (PR2-IMMT2 alignment).
X arm IR alignment (GR/IR resonance check).
X arm GR/IR alignment Established.
Y arm IR alignment Preparation.
Y arm IR alignment (Resonate IR).
Y arm IR alignment (Check spot position on ETMY).
Y arm IR align (Adjust BS for ETMY spot centering).
Y arm IR alignment (ITMY,ETMY alignment).
Y arm IR alignment (Check spot on ITMY).
Y arm IR alignment Established.
Y arm IR alignment (Record good TMSY).
Y arm IR alignment Established.
Y arm GR alignment (Resonate GR).
Y arm GR alignment (TMSY GR maximize with SR3).
Y arm GR/IR alignment Established.
FPMI Recovery (Exit from alignment mode).
FPMI Recovery (Align ITMX).
FPMI Recovery (Start FPMI).
How to realize X arm GR/IR alignment(from IMMT2(SR3) to ETMXY)


 1. '''Enter Alignment Mode1'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "LSC_Lock" in Commissioning.Doc.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.MAIN.png|LSC_Lock]].
  * Select "DOWN" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.STATES.png|All]].

 * '''Enter Alignment Mode2'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
  * Select "! engage" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].

 * ''' X arm GR alignment (ITMY misalign).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "VIS_ITMY" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMY_MAIN.png|VIS_ITMY]].
  * Select "Misaligned" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMY_STATES.png|All]].

 * ''' X arm GR alignment (Resonate GR).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "XARM" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img//GRD-XARM_MAIN.png|XARM]].
  * Select "Misaligned" in [[http://172.16.32.60/kagra_mannual/img/GRD-XARM_STATES.png|All]].
  * You can see [[http://172.16.32.60/kagra_mannual/img/AOS-TMSX_GR_PDA1_OUTPUT.png|K1:AOS-TMSX_GR_PDA1_OUTPUT]] enhancement.

 * ''' X arm GR alignment (Check spot position).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select CAMERA.
  * Select "TCAM Comm Mode" in [[http://172.16.32.60/kagra_mannual/img/IFO_CAM.png|CAMERA]].
  * Select "X_end_TCAM Commissioning mode start in [[http://172.16.32.60/kagra_mannual/img/CAL_TCAM.png|TCAM Comm Mode]]".
  * access [[http://172.16.33.39/vacuum|http://172.16.33.39/vacuum]] for ETMX Spot Monitoring.
  * access "! Tcam IX" for ITMX Spot Monitoring in [[http://172.16.32.60/kagra_mannual/img/IFO_CAM.png|CAMERA]].

 * ''' X arm GR alignment (PR3 Dithering).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "XARM" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/GRD-XARM_MAIN.png|XARM]].
  * Select "MANUAL", then "ENGAGE_PR3_ADS" in [[http://172.16.32.60/kagra_mannual/img/GRD-XARM_STATES.png|All]].

 * ''' X arm GR alignment (find good FP axis & PR3 P/Y).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "ALL VIS" in Commissioning.Doc.
  * Select "CRY-P" for both ITMX and ETMX in [[http://172.16.32.60/kagra_mannual/img/VIS_ALL.png|ALL VIS]].
  * Select "OL SETPOINT" for ITMX and ETMX in [[http://172.16.32.60/kagra_mannual/img/CRY_CUST_TYPEA_OVERVIEW.png|CRY-P]].
  * You can find for both ITMX and ETMX. Right click on [[http://172.16.32.60/kagra_mannual/img/CRY_CUST_TYPEA_MN_OLSET.png|slide bar]] and select “-1” as an increment. Never select large increment.
  * Adjust (IE)TMX alignment to lead their spots on both (IE)TMX to be around center. Ideally, K1:AOS-TMSX_GR_PDA1_OUTPUT should be maximized.
  *Or, Maximize K1:AOS-TMSX_GR_PDA1_OUTPUT by adjusting, firstly Yaw of IETMX and secondly Pitch.
   1. Remember the value of [[http://172.16.32.60/kagra_mannual/img/AOS-TMSX_GR_PDA1_OUTPUT.png|K1:AOS-TMSX_GR_PDA1_OUTPUT]] (assuming VtmsxGR-0).
   * Anyway, move Yaw/ETMX in one direction until you observe slight reduction of VtmsxGR-0.
   * Move Yaw/ITMX in both direction to find max of VtmsxGR.
   * (4-1) If you can find better VtmsxGR than VtmsxGR-0, it means your selection for ETMX actuation is good direction.
     (4-2) If worse, bad direction.
   * If good, repeat (2) (3) until you encounter (4-2). If bad, select opposite actuation then repeat (2)(3) until you encounter (4-2) again.
   * If you find max point, perform (1)~(5) for Pitch/(IE)TMX.
   (1)~(6) is regarded as one “set” optimization.Ideally, it is better to perform 2 sets for each Yaw/Pitch.

 * '''[[http://172.16.32.60/kagra_mannual/img/XarmGRalignment.jpg|X arm FP axis is established and PR3 P/Y is fixed]].'''


 * '''X arm GR alignment (Record good TMSX).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
  * Push “! record TMS QPD" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].

 * '''X arm IR alignment (Resonate IR).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "XARM" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/GRD-XARM_MAIN.png|XARM]].
  * Select "IR_LOCKED" in [[http://172.16.32.60/kagra_mannual/img/GRD-XARM_STATES.png|All]].
  * You can see [[http://172.16.32.60/kagra_mannual/img/AOS-TMSX_GR_PDA1_OUTPUT.png|K1:AOS-TMSX_GR_PDA1_OUTPUT]] enhancement.

 * '''X arm IR alignment (PR2-IMMT2 alignment).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "ALL VIS" in Commissioning.Doc.
  * Select PR2 "OVERViEW" in [[http://172.16.32.60/kagra_mannual/img/VIS_ALL.png|ALL VIS]].
  * Select "OPTIC SETPOINT" for PR2 in [[http://172.16.32.60/kagra_mannual/img/VIS_TYPEBP_OVERVIEW.png|OVERVIEW for PR2]].
  * You can find for PR2. Right click on [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEBP_TM_SETPOINT.png|slide bar]] and select “-1” as an increment. Never select large increment.

  * Select "IMMT2 in [[http://172.16.32.60/kagra_mannual/img/VIS_ALL.png|ALL VIS]].
  * Select "OLSET OPTIC" for IMMT2. in [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEC_OVERVIEW.png| OVERVIEW for IMMT2]].
  * You can find for IMMT2. Right click on [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEC_TM_OLSET.png|slide bar]] and select “-1” as an increment. Never select large increment.

  * Maximize K1:AOS-TMSX_IR_PDA1_OUTPUT by adjusting, firstly Yaw of PR2/IMMT2 and secondly Pitch.
   1. Remember the value of [[http://172.16.32.60/kagra_mannual/img/AOS-TMSX_GR_PDA1_OUTPUT.png|K1:AOS-TMSX_IR_PDA1_OUTPUT]] (assuming VtmsxIR-0).
   * Anyway, move Yaw/PR2 in one direction until you observe slight reduction of VtmsxIR-0.
   * Move Yaw/IMMT2 in both direction to find max of VtmsxIR.
   * (4-1) If you can find better VtmsxIR than VtmsxIR-0, it means your selection for PR2 actuation is good direction.
     (4-2) If worse, bad direction.
   * If good, repeat (2) (3) until you encounter (4-2). If bad, select opposite actuation then repeat (2)(3) until you encounter (4-2) again.
   * If you find max point, perform (1)~(5) forPitch/PR2/IMMT2.
   (1)~(6) is regarded as one “set” optimization.Ideally, it is better to perform 2 sets for each Yaw/Pitch.


 * '''X arm IR alignment (GR/IR resonance check).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
  * Select "Align Xarm" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].
  * Wait until auto alignment seems to be stable.
  * Select left “!record” for GR, select“!record” for IR.
  * Select “Disable Xarm”


 * '''[[http://172.16.32.60/kagra_mannual/img/XarmGRIRalignment.jpg|X arm GR/IR alignment Established]].'''


 * '''Y arm IR alignment Preparation.'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "VIS_ITMY" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMY_MAIN.png|VIS_ITMY]].
  * Select "ALIGNED" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMY_STATES.png|All]].
  * Select "VIS_ITMX" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMX_MAIN.png|VIS_ITMX]].
  * Select "MISALIGNED" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMX_STATES.png|All]].

 * '''Y arm IR alignment (Resonate IR).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "YARM" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/GRD-YARM_MAIN.png|YARM]].
  * Select "IR_LOCKED" in [[http://172.16.32.60/kagra_mannual/img/GRD-YARM_STATES.png|All]].
  * You can see [[http://172.16.32.60/kagra_mannual/img/AOS-TMSY_IR_PDA1_OUTPUT.png|K1:AOS-TMSY_IR_PDA1_OUTPUT]] enhancement.


 * '''Y arm IR alignment (Check spot position on ETMY).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select CAMERA.
  * Select "TCAM Comm Mode" in [[http://172.16.32.60/kagra_mannual/img/IFO_CAM.png|CAMERA]].
  * Select "Y_end_TCAM Commissioning mode start in [[http://172.16.32.60/kagra_mannual/img/CAL_TCAM.png|TCAM Comm Mode]]".
  * access [[http://172.16.33.39/vacuum|http://172.16.33.39/vacuum]] for ETMY Spot Monitoring.
  * access "! Tcam IY" for ITMY Spot Monitoring in [[http://172.16.32.60/kagra_mannual/img/IFO_CAM.png|CAMERA]].


 * '''Y arm IR align (Adjust BS for ETMY spot centering).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "ALL VIS" in Commissioning.Doc.
  * Select Bs "OVERViEW" in [[http://172.16.32.60/kagra_mannual/img/VIS_ALL.png|ALL VIS]].
  * Select "OLSET OPTIC" for BS in [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEB_OVERVIEW.png|OVERVIEW for BS]].
  * You can find for BS. Right click on [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEB_IM_OPTICALIGN.png|slide bar]] and select “-1” as an increment. Never select large increment.
  * Adjust Pitch and Yaw to set the beam spot around the center of ETMY with eyeball on [[http://172.16.33.39/vacuum|http://172.16.33.39/vacuum]].


 * '''Y arm IR alignment (ITMY,ETMY alignment).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "ALL VIS" in Commissioning.Doc.
  * Select "CRY-P" for both ITMY and ETMY in [[http://172.16.32.60/kagra_mannual/img/VIS_ALL.png|ALL VIS]].
  * Select "OL SETPOINT" for ITMX and ETMX in [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEA_OVERVIEW.png|CRY-P]].
  * You can find for both ITMX and ETMX. Right click on [[http://172.16.32.60/kagra_mannual/img/CRY_CUST_TYPEA_MN_OLSET.png|slide bar]] and select “-1” as an increment. Never select large increment.
  * Maximize K1:AOS-TMSY_IR_PDA1_OUTPUT by adjusting, firstly Yaw of IETMY and secondly Pitch.
   1. Remember the value of [[http://172.16.32.60/kagra_mannual/img/AOS-TMSY_IR_PDA1_OUTPUT.png|K1:AOS-TMSY_IR_PDA1_OUTPUT]] (assuming VtmsyIR-0).
   * Anyway, move Yaw/ETMY in one direction until you observe slight reduction of VtmsyIR-0.
   * Move Yaw/ITMX in both direction to find max of VtmsyIR.
   * (4-1) If you can find better VtmsyIR than VtmsyIR-0, it means your selection for ETMY actuation is good direction.
     (4-2) If worse, bad direction.
   * If good, repeat (2) (3) until you encounter (4-2). If bad, select opposite actuation then repeat (2)(3) until you encounter (4-2) again.
   * If you find max point, perform (1)~(5) for Pitch/(IE)TMY.
   (1)~(6) is regarded as one “set” optimization.Ideally, it is better to perform 2 sets for each Yaw/Pitch.


 * '''Y arm IR alignment (Check spot on ITMY).'''

  *Check the position of spot on ITMY. We have no way to set it around the center of ITMY because the spot position on ITMY should be adjusted by suspension. However we don’t do at present. So the position on ITMY is just decided by setting accuracy.

 * '''[[http://172.16.32.60/kagra_mannual/img/YarmIRalignment.jpg|Y arm IR alignment Established]].'''


 * '''Y arm IR alignment (Record good TMSY).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
  * Push “! record TMS QPD" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].


 * '''Y arm GR alignment (Resonate GR).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "YARM" in Guardian Overview.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMY_MAIN.png|YARM]].
  * Select "ALS_LOCKED" in [[http://172.16.32.60/kagra_mannual/img/GRD-YARM_STATES.png|All]].
  * You can see [[http://172.16.32.60/kagra_mannual/img/AOS-TMSY_IR_PDA1_OUTPUT.png|K1:AOS-TMSY_GR_PDA1_OUTPUT]] enhancement.


 * '''Y arm GR alignment (TMSY GR maximize with SR3).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "ALL VIS" in Commissioning.Doc.
  * Select SR3 "OVERViEW" in [[http://172.16.32.60/kagra_mannual/img/VIS_ALL.png|ALL VIS]].
  * Select "OLSET OPTIC" for BS in [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEB_OVERVIEW.png|OVERVIEW for PR3]].
  * You can find for PR3. Right click on [[http://172.16.32.60/kagra_mannual/img/VIS_CUST_TYPEB_IM_OPTICALIGN.png|slide bar]] and select “-1” as an increment. Never select large increment.
  * Adjust Pitch and Yaw to maximize to maximize [[http://172.16.32.60/kagra_mannual/img/AOS-TMSY_IR_PDA1_OUTPUT.png|K1:AOS-TMSY_GR_PDA1_OUTPUT]].


 * '''[[http://172.16.32.60/kagra_mannual/img/YarmGRIRalignment.jpg|Y arm GR/IR alignment Established]].'''

 * '''FPMI Recovery (Exit from alignment mode).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
  * Select "! disable" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].


 * '''FPMI Recovery (Align ITMX).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/guardian_overview.png|Guardian Overview]].
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMX_MAIN.png|VIS_ITMX]].
  * Select "ALIGNED" in [[http://172.16.32.60/kagra_mannual/img/guard-VIS_ITMX_STATES.png|All]].


 * '''FPMI Recovery (Start FPMI).'''

  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "LSC_Lock" in Commissioning.Doc.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.MAIN.png|LSC_Lock]].
  * Select "FPMI LOCKED" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.STATES.png|All]].

How to realize X arm GR/IR alignment(from IMMT2(SR3) to ETMXY)

  1. Enter Alignment Mode1

  2. Enter Alignment Mode2

  3. X arm GR alignment (ITMY misalign).

  4. X arm GR alignment (Resonate GR).

  5. X arm GR alignment (Check spot position).

  6. X arm GR alignment (PR3 Dithering).

    • Go to Guardian Overview.

    • Select "XARM" in Guardian Overview.
    • Select "request [All]" in XARM.

    • Select "MANUAL", then "ENGAGE_PR3_ADS" in All.

  7. X arm GR alignment (find good FP axis & PR3 P/Y).

    • Go to Commissioning.Doc.

    • Select "ALL VIS" in Commissioning.Doc.
    • Select "CRY-P" for both ITMX and ETMX in ALL VIS.

    • Select "OL SETPOINT" for ITMX and ETMX in CRY-P.

    • You can find for both ITMX and ETMX. Right click on slide bar and select “-1” as an increment. Never select large increment.

    • Adjust (IE)TMX alignment to lead their spots on both (IE)TMX to be around center. Ideally, K1:AOS-TMSX_GR_PDA1_OUTPUT should be maximized.
    • Or, Maximize K1:AOS-TMSX_GR_PDA1_OUTPUT by adjusting, firstly Yaw of IETMX and secondly Pitch.
      1. Remember the value of K1:AOS-TMSX_GR_PDA1_OUTPUT (assuming VtmsxGR-0).

      2. Anyway, move Yaw/ETMX in one direction until you observe slight reduction of VtmsxGR-0.
      3. Move Yaw/ITMX in both direction to find max of VtmsxGR.
      4. (4-1) If you can find better VtmsxGR than VtmsxGR-0, it means your selection for ETMX actuation is good direction.
        • (4-2) If worse, bad direction.
      5. If good, repeat (2) (3) until you encounter (4-2). If bad, select opposite actuation then repeat (2)(3) until you encounter (4-2) again.
      6. If you find max point, perform (1)~(5) for Pitch/(IE)TMX. (1)~(6) is regarded as one “set” optimization.Ideally, it is better to perform 2 sets for each Yaw/Pitch.
  8. X arm FP axis is established and PR3 P/Y is fixed.

  9. X arm GR alignment (Record good TMSX).

  10. X arm IR alignment (Resonate IR).

  11. X arm IR alignment (PR2-IMMT2 alignment).

    • Go to Commissioning.Doc.

    • Select "ALL VIS" in Commissioning.Doc.
    • Select PR2 "OVERViEW" in ALL VIS.

    • Select "OPTIC SETPOINT" for PR2 in OVERVIEW for PR2.

    • You can find for PR2. Right click on slide bar and select “-1” as an increment. Never select large increment.

    • Select "IMMT2 in ALL VIS.

    • Select "OLSET OPTIC" for IMMT2. in OVERVIEW for IMMT2.

    • You can find for IMMT2. Right click on slide bar and select “-1” as an increment. Never select large increment.

    • Maximize K1:AOS-TMSX_IR_PDA1_OUTPUT by adjusting, firstly Yaw of PR2/IMMT2 and secondly Pitch.
      1. Remember the value of K1:AOS-TMSX_IR_PDA1_OUTPUT (assuming VtmsxIR-0).

      2. Anyway, move Yaw/PR2 in one direction until you observe slight reduction of VtmsxIR-0.
      3. Move Yaw/IMMT2 in both direction to find max of VtmsxIR.
      4. (4-1) If you can find better VtmsxIR than VtmsxIR-0, it means your selection for PR2 actuation is good direction.
        • (4-2) If worse, bad direction.
      5. If good, repeat (2) (3) until you encounter (4-2). If bad, select opposite actuation then repeat (2)(3) until you encounter (4-2) again.
      6. If you find max point, perform (1)~(5) forPitch/PR2/IMMT2. (1)~(6) is regarded as one “set” optimization.Ideally, it is better to perform 2 sets for each Yaw/Pitch.
  12. X arm IR alignment (GR/IR resonance check).

    • Go to Commissioning.Doc.

    • Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
    • Select "Align Xarm" in SEMI AUTO ALIGNMENT.

    • Wait until auto alignment seems to be stable.
    • Select left “!record” for GR, select“!record” for IR.
    • Select “Disable Xarm”
  13. X arm GR/IR alignment Established.

  14. Y arm IR alignment Preparation.

    • Go to Guardian Overview.

    • Select "VIS_ITMY" in Guardian Overview.
    • Select "request [All]" in VIS_ITMY.

    • Select "ALIGNED" in All.

    • Select "VIS_ITMX" in Guardian Overview.
    • Select "request [All]" in VIS_ITMX.

    • Select "MISALIGNED" in All.

  15. Y arm IR alignment (Resonate IR).

  16. Y arm IR alignment (Check spot position on ETMY).

  17. Y arm IR align (Adjust BS for ETMY spot centering).

    • Go to Commissioning.Doc.

    • Select "ALL VIS" in Commissioning.Doc.
    • Select Bs "OVERViEW" in ALL VIS.

    • Select "OLSET OPTIC" for BS in OVERVIEW for BS.

    • You can find for BS. Right click on slide bar and select “-1” as an increment. Never select large increment.

    • Adjust Pitch and Yaw to set the beam spot around the center of ETMY with eyeball on http://172.16.33.39/vacuum.

  18. Y arm IR alignment (ITMY,ETMY alignment).

    • Go to Commissioning.Doc.

    • Select "ALL VIS" in Commissioning.Doc.
    • Select "CRY-P" for both ITMY and ETMY in ALL VIS.

    • Select "OL SETPOINT" for ITMX and ETMX in CRY-P.

    • You can find for both ITMX and ETMX. Right click on slide bar and select “-1” as an increment. Never select large increment.

    • Maximize K1:AOS-TMSY_IR_PDA1_OUTPUT by adjusting, firstly Yaw of IETMY and secondly Pitch.
      1. Remember the value of K1:AOS-TMSY_IR_PDA1_OUTPUT (assuming VtmsyIR-0).

      2. Anyway, move Yaw/ETMY in one direction until you observe slight reduction of VtmsyIR-0.
      3. Move Yaw/ITMX in both direction to find max of VtmsyIR.
      4. (4-1) If you can find better VtmsyIR than VtmsyIR-0, it means your selection for ETMY actuation is good direction.
        • (4-2) If worse, bad direction.
      5. If good, repeat (2) (3) until you encounter (4-2). If bad, select opposite actuation then repeat (2)(3) until you encounter (4-2) again.
      6. If you find max point, perform (1)~(5) for Pitch/(IE)TMY. (1)~(6) is regarded as one “set” optimization.Ideally, it is better to perform 2 sets for each Yaw/Pitch.
  19. Y arm IR alignment (Check spot on ITMY).

    • Check the position of spot on ITMY. We have no way to set it around the center of ITMY because the spot position on ITMY should be adjusted by suspension. However we don’t do at present. So the position on ITMY is just decided by setting accuracy.
  20. Y arm IR alignment Established.

  21. Y arm IR alignment (Record good TMSY).

  22. Y arm GR alignment (Resonate GR).

  23. Y arm GR alignment (TMSY GR maximize with SR3).

  24. Y arm GR/IR alignment Established.

  25. FPMI Recovery (Exit from alignment mode).

  26. FPMI Recovery (Align ITMX).

  27. FPMI Recovery (Start FPMI).