'''How to realize X arm GR/IR alignment(from IMMT2(SR3) to ETMXY)''' ***'''How to realize X arm GR/IR alignment(from IMMT2(SR3) to ETMXY)'''
Line 3: Line 3:
1. '''Enter Alignment Mode1'''
Line 5: Line 4:
 * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
 * Select "LSC_Lock" in Commissioning.Doc.
 * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.MAIN.png|LSC_Lock]].
 * Select "DOWN" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.STATES.png|All]].
 1. '''Enter Alignment Mode1'''
 
* Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "LSC_Lock" in Commissioning.Doc.
  * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.MAIN.png|LSC_Lock]].
  * Select "DOWN" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.STATES.png|All]].
Line 10: Line 10:
2'''Enter Alignment Mode2'''  * '''Enter Alignment Mode2'''
Line 12: Line 12:
 * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
 * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
 * Select "! engage" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].
  * Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]].
  * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc.
  * Select "! engage" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]].
Line 16: Line 16:
 X arm GR alignment (ITMY misalign).
X arm GR alignment (Resonate GR).
X arm GR alignment (Check spot position).
X arm GR alignment (PR3 Dithering).
X arm GR alignment (find good FP axis & PR3 P/Y).
X arm FP axis is established and PR3 P/Y is fixed.
X arm GR alignment (Record good TMSX).
X arm IR alignment (Resonate IR).
X arm IR alignment (PR2-IMMT2 alignment).
X arm IR alignment (GR/IR resonance check).
X arm GR/IR alignment Established.
Y arm IR alignment Preparation.
Y arm IR alignment (Resonate IR).
Y arm IR alignment (Check spot position on ETMY).
Y arm IR align (Adjust BS for ETMY spot centering).
Y arm IR alignment (ITMY,ETMY alignment).
Y arm IR alignment (Check spot on ITMY).
Y arm IR alignment Established.
Y arm IR alignment (Record good TMSY).
Y arm IR alignment Established.
Y arm GR alignment (Resonate GR).
Y arm GR alignment (TMSY GR maximize with SR3).
Y arm GR/IR alignment Established.
FPMI Recovery (Exit from alignment mode).
FPMI Recovery (Align ITMX).
FPMI Recovery (Start FPMI).
 * ''' X arm GR alignment (ITMY misalign).'''
 * '''
X arm GR alignment (Resonate GR).'''
 * '''
X arm GR alignment (Check spot position).'''
 * '''
X arm GR alignment (PR3 Dithering).'''
 * '''
X arm GR alignment (find good FP axis & PR3 P/Y).'''
 * '''
X arm FP axis is established and PR3 P/Y is fixed.'''
 * '''
X arm GR alignment (Record good TMSX).'''
 * '''
X arm IR alignment (Resonate IR).'''
 * '''
X arm IR alignment (PR2-IMMT2 alignment).'''
 * '''
X arm IR alignment (GR/IR resonance check).'''
 * '''
X arm GR/IR alignment Established.'''
 * '''
Y arm IR alignment Preparation.'''
 * '''Y arm IR alignment (Resonate IR).'''
 * '''
Y arm IR alignment (Check spot position on ETMY).'''
 * '''
Y arm IR align (Adjust BS for ETMY spot centering).'''
 * '''
Y arm IR alignment (ITMY,ETMY alignment).'''
 * '''
Y arm IR alignment (Check spot on ITMY).'''
 * '''
Y arm IR alignment Established.'''
 * '''
Y arm IR alignment (Record good TMSY).'''
 * '''
Y arm IR alignment Established.'''
 * '''Y arm GR alignment (Resonate GR).'''
 * '''
Y arm GR alignment (TMSY GR maximize with SR3).'''
 * '''
Y arm GR/IR alignment Established.'''
 * '''
FPMI Recovery (Exit from alignment mode).'''
 * '''
FPMI Recovery (Align ITMX).'''
 * '''
FPMI Recovery (Start FPMI).'''

***How to realize X arm GR/IR alignment(from IMMT2(SR3) to ETMXY)

  1. Enter Alignment Mode1

  2. Enter Alignment Mode2

  3. X arm GR alignment (ITMY misalign).

  4. X arm GR alignment (Resonate GR).

  5. X arm GR alignment (Check spot position).

  6. X arm GR alignment (PR3 Dithering).

  7. X arm GR alignment (find good FP axis & PR3 P/Y).

  8. X arm FP axis is established and PR3 P/Y is fixed.

  9. X arm GR alignment (Record good TMSX).

  10. X arm IR alignment (Resonate IR).

  11. X arm IR alignment (PR2-IMMT2 alignment).

  12. X arm IR alignment (GR/IR resonance check).

  13. X arm GR/IR alignment Established.

  14. Y arm IR alignment Preparation.

  15. Y arm IR alignment (Resonate IR).

  16. Y arm IR alignment (Check spot position on ETMY).

  17. Y arm IR align (Adjust BS for ETMY spot centering).

  18. Y arm IR alignment (ITMY,ETMY alignment).

  19. Y arm IR alignment (Check spot on ITMY).

  20. Y arm IR alignment Established.

  21. Y arm IR alignment (Record good TMSY).

  22. Y arm IR alignment Established.

  23. Y arm GR alignment (Resonate GR).

  24. Y arm GR alignment (TMSY GR maximize with SR3).

  25. Y arm GR/IR alignment Established.

  26. FPMI Recovery (Exit from alignment mode).

  27. FPMI Recovery (Align ITMX).

  28. FPMI Recovery (Start FPMI).