665
Comment:
|
4003
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
Test page | == [1] Clean booth == * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3599 | Laser Room]] * [[ https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3588 | PR-area (including MCF-IFI-MMT-PRM-PR3) & BS-area (including PR2, BS, SR2) & EXC, EYC]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=6447 | SR-area (including SR3, SRM, OMC) & I(XY)C & I(XY)V ]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12521 | I(XY)A ]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12522 | Pre-Clean Room for PSL/PR-area ]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12523| Kotohira FFU ULPA for mainly IEXYA, IEXYV]] * [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12524 | MAC-2A-251DC-ULS-(dial) ]] |
Line 3: | Line 10: |
'''Enter Alignment Mode1''' | == [2] Heat Generators == |
Line 5: | Line 12: |
* Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]]. * Select "LSC_Lock" in Commissioning.Doc. * Select "request [All]" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.MAIN.png|LSC_Lock]]. * Select "DOWN" in [[http://172.16.32.60/kagra_mannual/img/gurad-LSC_LOCK.STATES.png|All]]. |
|| |||| Items |||| O4a |||| June/30 |||| || || IXV |||| Air conditioner |||| x (weak, 20C) |||| o (strong, 20C) |||| || || |||| Delongho Heater |||| x |||| o L1 |||| || || |||| Ceiling Lights |||| o |||| o |||| || || |||| TMP/Scrolls |||| x |||| o |||| || || |||| Ion Pump |||| o |||| x |||| || || |||| FFUs |||| 2 |||| 2 |||| || |
Line 10: | Line 20: |
'''Enter Alignment Mode2''' | || IYV |||| Air conditioner |||| o (weak, 20C) |||| o (weak, 20C) |||| || || |||| Delongho Heater |||| o L4 |||| o L1 |||| || || |||| Ceiling Lights |||| o |||| o |||| || || |||| TMP/Scrolls |||| x |||| o |||| || || |||| Ion Pump |||| o |||| x |||| || || |||| FFUs |||| 2 |||| 2 |||| || |
Line 12: | Line 27: |
* Go to [[http://172.16.32.60/kagra_mannual/img/commissioning_doc.png|Commissioning.Doc]]. * Select "SEMI AUTO ALIGNMENT" in Commissioning.Doc. * Select "! engage" in [[http://172.16.32.60/kagra_mannual/img/salignment.png|SEMI AUTO ALIGNMENT]]. |
|| Corner 1F |||| Precision Cooler |||| o(19.00) |||| o(19.00) |||| || || |||| Daikin Cooler MCF-C |||| x |||| x |||| || || |||| Daikin Cooler BS-C |||| x |||| o |||| || || |||| Daikin Cooler SR-C |||| x |||| x |||| || || |||| Daikin Cooler IYC-C |||| x |||| x |||| || || |||| Ceiling Lights A |||| 1/2 |||| 1/2 |||| || || |||| Ceiling Lights B |||| 1/2 |||| 1/2 |||| || || |||| Ceiling Lights C |||| 1/1 |||| 1/1 |||| || || |||| Ceiling Lights IXC |||| 1/2 |||| 1/2 |||| || || |||| Ceiling Lights IYC |||| 1/2 |||| 1/2 |||| || || |||| Sunrise Heater BS |||| x |||| x |||| || || |||| Sunrise Heater SR2 |||| x |||| x |||| || || |||| Sunrise Heater OMC |||| x |||| x |||| || || |||| Sunrise Heater PR2 |||| x |||| x |||| || || |||| Sunrise Heater DGS |||| x |||| x |||| || || |||| Delonghi Heater MCF |||| o L2 |||| x |||| || || |||| FFUs |||| ?? |||| ?? |||| || || IXC |||| TMP/Scrolls |||| 3 x |||| 3 o |||| || || |||| Ion Pump |||| 2 o |||| 2 x |||| || || |||| Duct Shield Cooler |||| 2 o |||| 2 x |||| || || |||| Radiation Shield Cooler |||| 2 x |||| 2 x |||| || || |||| Payload Cooler |||| 2 x |||| 2 x |||| || || |||| FFUs |||| ?? |||| ?? |||| || || IYC |||| TMP/Scrolls |||| 3 x |||| 3 o |||| || || |||| Ion Pump |||| 2 o |||| 2 x |||| || || |||| Duct Shield Cooler |||| 2 o |||| 2 x |||| || || |||| Radiation Shield Cooler |||| 2 x |||| 2 x |||| || || |||| Payload Cooler |||| 2 x |||| 2 x |||| || || |||| FFUs |||| ?? |||| ?? |||| || || IXC |||| TMP/Scrolls |||| x |||| x |||| || || |||| FFUs |||| ?? |||| ?? |||| || || IYC |||| TMP/Scrolls |||| x |||| o |||| || || |||| FFUs |||| ?? |||| ?? |||| || |
[1] Clean booth
[2] Heat Generators
|
Items |
O4a |
June/30 |
|
||||
IXV |
Air conditioner |
x (weak, 20C) |
o (strong, 20C) |
|
||||
|
Delongho Heater |
x |
o L1 |
|
||||
|
Ceiling Lights |
o |
o |
|
||||
|
TMP/Scrolls |
x |
o |
|
||||
|
Ion Pump |
o |
x |
|
||||
|
FFUs |
2 |
2 |
|
IYV |
Air conditioner |
o (weak, 20C) |
o (weak, 20C) |
|
||||
|
Delongho Heater |
o L4 |
o L1 |
|
||||
|
Ceiling Lights |
o |
o |
|
||||
|
TMP/Scrolls |
x |
o |
|
||||
|
Ion Pump |
o |
x |
|
||||
|
FFUs |
2 |
2 |
|
Corner 1F |
Precision Cooler |
o(19.00) |
o(19.00) |
|
||||
|
Daikin Cooler MCF-C |
x |
x |
|
||||
|
Daikin Cooler BS-C |
x |
o |
|
||||
|
Daikin Cooler SR-C |
x |
x |
|
||||
|
Daikin Cooler IYC-C |
x |
x |
|
||||
|
Ceiling Lights A |
1/2 |
1/2 |
|
||||
|
Ceiling Lights B |
1/2 |
1/2 |
|
||||
|
Ceiling Lights C |
1/1 |
1/1 |
|
||||
|
Ceiling Lights IXC |
1/2 |
1/2 |
|
||||
|
Ceiling Lights IYC |
1/2 |
1/2 |
|
||||
|
Sunrise Heater BS |
x |
x |
|
||||
|
Sunrise Heater SR2 |
x |
x |
|
||||
|
Sunrise Heater OMC |
x |
x |
|
||||
|
Sunrise Heater PR2 |
x |
x |
|
||||
|
Sunrise Heater DGS |
x |
x |
|
||||
|
Delonghi Heater MCF |
o L2 |
x |
|
||||
|
FFUs |
?? |
?? |
|
IXC |
TMP/Scrolls |
3 x |
3 o |
|
||||
|
Ion Pump |
2 o |
2 x |
|
||||
|
Duct Shield Cooler |
2 o |
2 x |
|
||||
|
Radiation Shield Cooler |
2 x |
2 x |
|
||||
|
Payload Cooler |
2 x |
2 x |
|
||||
|
FFUs |
?? |
?? |
|
IYC |
TMP/Scrolls |
3 x |
3 o |
|
||||
|
Ion Pump |
2 o |
2 x |
|
||||
|
Duct Shield Cooler |
2 o |
2 x |
|
||||
|
Radiation Shield Cooler |
2 x |
2 x |
|
||||
|
Payload Cooler |
2 x |
2 x |
|
||||
|
FFUs |
?? |
?? |
|
IXC |
TMP/Scrolls |
x |
x |
|
||||
|
FFUs |
?? |
?? |
|
IYC |
TMP/Scrolls |
x |
o |
|
||||
|
FFUs |
?? |
?? |
|