Differences between revisions 22 and 32 (spanning 10 versions)
Revision 22 as of 2020-05-26 11:19:15
Size: 8005
Editor: KousekiMiyo
Comment:
Revision 32 as of 2020-05-26 11:58:39
Size: 8896
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 74: Line 74:
メモ:歪み計算をしているコードについて載せる
 * 一旦、ログインして眺めないとわからない。
 * どこかにメモがあったかなぁ
Line 77: Line 80:
== UPS ==
|| 場所 || 用途 || 本体型番(バッテリー) || 交換日時 ||
|| 北部会館 || データ処理計算機用 || [[https://socialsolution.omron.com/jp/ja/products_service/ups/product/by35-120s/by35-120s.html|BY80S]]([[https://socialsolution.omron.com/jp/ja/products_service/ups/product/battery/byb80s/byb80s.html|BYB80S]]) || --- ||
|| CLIO坑内 || --- || --- || --- ||
|| GIF坑内 || --- || --- || --- ||
== Maintainance ==
=== UPS ===
|| 場所 || 本体型番(バッテリー) || 製造/サポート ||交換日時 ||
|| 北部会館2階 計算機用 || [[https://socialsolution.omron.com/jp/ja/products_service/ups/product/by35-120s/by35-120s.html|BY80S]]([[https://socialsolution.omron.com/jp/ja/products_service/ups/product/battery/byb80s/byb80s.html|BYB80S]]) || / || --- ||
|| 北部会館2階 計算機用 || [[https://socialsolution.omron.com/jp/ja/products_service/ups/product/by35-120s/by35-120s.html|BY80S?]]([[https://socialsolution.omron.com/jp/ja/products_service/ups/product/battery/byb80s/byb80s.html|BYB80S]]) || / || --- ||
|| CLIO Laser, Vacuum || [[https://www.mitsubishielectric.co.jp/fa/products/faspec/point.do?kisyu=/ups&formNm=FW-V_FW-V10-0.7K_1&category=ex&id=spec|FW-V10-0.7K]] ([[xxx|FW-VBT-0.7K]]) || / || 2020/03||
|| CLIO 計算機用 || [[https://www.apc.com/shop/jp/ja/products/APC-Smart-UPS-1000-LCD-100V/P-SMT1000J|Smart-UPS 1000 LCD 100V]] ([[https://www.apc.com/shop/jp/ja/products/APC-6-/P-RBC6L|RBC6L]]) || / || --- ||
|| GIF 坑内用 || [[xxx|xxx]] || / || --- ||

メモ:ここには、地震研のDAQの情報を載せる。

  • 計算機、データ保管場所、チャンネル名など。
  • その他、UPSなどの交換などの情報を載せる。


DAQ of ERI

Computer

IP address

Name

Memo

172.16.32.xxx

PXI

for PD of the strainmeter. MAx: 24-bit 50kS/s. 1

172.16.32.208

cRIO01

for the environment monitor. Max:24-bit 12.5kS/s

172.16.32.209

cRIO02

for the environment monitor. Max:24-bit 12.5kS/s

172.16.32.218

cRIO03

for the environment monitor. Max:24-bit 12.5kS/s

172.16.32.219

Pxi Sub

Buffer1 :

172.16.32.202

KAGRA-DATA

Buffer2 :

172.16.32.210

NAS

Data server

172.16.32.201

KAGRA-CM

DAQ monitor

Raw Data

Update Nov 15 2018, Miyo

Location

DAQ Name

File Location

File Extension

Data Type

Sampling
Rate

Usage 

Calibration

X500

cRIO01

/NAS/cRIO01_data/

.AD00

4 Byte
Integer

200Hz

Temperature [℃] 

1.25e-6 [V/count], [℃/V]

.AD01

4 Byte
Integer

200Hz

Humidity {%} 

1.25e-6 [V/count], [%/V]

.AD02

4 Byte
Integer

200Hz

Pressure [Pa]

1.25e-6 [V/count], [Pa/V]

.AD03

4 Byte
Integer

200Hz

Vaccum [Pa]

1.25e-6 [V/count], ??? [Pa/V]

.AD04

4 Byte
Integer

200Hz

PXI01 Power for 3.3V 

1.25e-6 [V/count]

.AD05

4 Byte
Integer

200Hz

PXI01 Power for 5.0V 

1.25e-6 [V/count]

.AD06

4 Byte
Integer

200Hz

PXI01 Power for +12V 

1.25e-6 [V/count]

.AD07

4 Byte
Integer

200Hz

PXI01 Power for -12V

1.25e-6 [V/count]

PXI01

/PXI_DATA2/PXI1_data/5Hz/Hz
or
/NAS/PXI_data/5000Hz
or
/NAS/PXI_data/50000Hz

.AD00

4 Byte
Integer

5Hz
or
5kHz
or
50kHz

PD1

5.525e-9 [V/count]

.AD01

4 Byte
Integer

5Hz
or
5kHz
or
50kHz

PD2

5.525e-9 [V/count]

.AD02

4 Byte
Integer

5Hz
or
5kHz
or
50kHz

Laser Amplitude

5.525e-9 [V/count]

.AD03

4 Byte
Integer

5Hz
or
5kHz
or
50kHz

Laser Absorption

5.525e-9 [V/count]

Location

DAQ Name

File Location

File Extension

Data Type

Sampling
Rate

Signal 

Calibration

X2000

cRIO02

/NAS/cRIO02_data/

.AD00

4 Byte
Integer

200Hz

Temperature 

1.25e-6 [V/count], [Degree/V]

.AD01

4 Byte
Integer

200Hz

Humidity 

1.25e-6 [V/count], [%/V]

.AD02

4 Byte
Integer

200Hz

Pressure 

1.25e-6 [V/count], [Pa/V]

.AD03

4 Byte
Integer

200Hz

Vaccum 

1.25e-6 [V/count]

.AD04

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD05

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD06

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD07

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]

Location

DAQ Name

File Location

File Extension

Data Type

Sampling
Rate

Signal 

Calibration

X1500

cRIO03

/NAS/cRIO03_data/

.AD00

4 Byte
Integer

200Hz

Trillium240 velocity EW 

1.25e-6 [V/count]

.AD01

4 Byte
Integer

200Hz

None 

1.25e-6 [V/count]

.AD02

4 Byte
Integer

200Hz

Trillium240 velocity NS 

1.25e-6 [V/count]

.AD03

4 Byte
Integer

200Hz

Trillium240 velocity UD 

1.25e-6 [V/count]

.AD04

4 Byte
Integer

200Hz

Trillium240 position EW 

1.25e-6 [V/count]

.AD05

4 Byte
Integer

200Hz

Trillium240 position NS 

1.25e-6 [V/count]

.AD06

4 Byte
Integer

200Hz

Trillium240 position UD 

1.25e-6 [V/count]

.AD07

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]

.AD08

4 Byte
Integer

200Hz

CMG3T velocity EW 

1.25e-6 [V/count]

.AD09

4 Byte
Integer

200Hz

CMG3T velocity NS 

1.25e-6 [V/count]

.AD10

4 Byte
Integer

200Hz

CMG3T velocity UD 

1.25e-6 [V/count]

.AD11

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]

.AD12

4 Byte
Integer

200Hz

CMG3T position EW 

1.25e-6 [V/count]

.AD13

4 Byte
Integer

200Hz

CMG3T position NS 

1.25e-6 [V/count]

.AD14

4 Byte
Integer

200Hz

CMG3T position UD 

1.25e-6 [V/count]

.AD15

4 Byte
Integer

200Hz

None

1.25e-6 [V/count]

Code

メモ:Rawデータを保存するスクリプトについて載せる

Strain Data

Data Location

data type

Sampling Rate [Hz]

File extension

Comment

/data1/PHASE/50000Hz

8byte float

200

.PHASE
.STRAIN
.ZOBUBN
.SQRT

calculated strain signal using 50kHz

/data2/CLIO/LIN

8byte float

200

.LIN

calculated strain signal

/data2/CLIO/SHR

8byte float

200

.SHR

calculated strain signal

Code

メモ:歪み計算をしているコードについて載せる

  • 一旦、ログインして眺めないとわからない。
  • どこかにメモがあったかなぁ


Maintainance

UPS

場所

本体型番(バッテリー)

製造/サポート

交換日時

北部会館2階 計算機用

BY80S(BYB80S)

/

---

北部会館2階 計算機用

BY80S?(BYB80S)

/

---

CLIO Laser, Vacuum

FW-V10-0.7K (FW-VBT-0.7K)

/

2020/03

CLIO 計算機用

Smart-UPS 1000 LCD 100V (RBC6L)

/

---

|| GIF 坑内用 || xxx || / || --- ||

KAGRA/Subgroups/GIF/DAQ/ERI (last edited 2024-03-03 08:55:16 by AkiteruTakamori)