4124
Comment:
|
4157
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
=== Data size === || DAQ name || data size || Voltage/Count || || cRIO || 4byte Little-Endian Integer || 1.25e-6 || || PXI || 4byte Little-Endian Integer || 5.525e-9|| |
<<TableOfContents(2)>> |
Line 6: | Line 3: |
=== Environmental Monitor of GIF === | == Data Configuration == All files are under the "/YYYY/MM/DD/" directory and filename format is "YYMMDDhhmm.xxx", where .xxx is file extension. ||<#E0F2F7> Data Location ||<#E0F2F7> data type ||<#E0F2F7> Sampling Rate [Hz] ||<#E0F2F7> Unit Conversion factor ||<#E0F2F7> File extension ||<#E0F2F7> Comment || || /NAS/cRIO01_data/ || 4byte Integer || 200 || 1.25e-6 [V/count] || .AD0[0-7] || for Env. signal || || /NAS/cRIO02_data/ || 4byte Integer || 200 || 1.25e-6 [V/count] || .AD0[0-7] || for Env. signal || || /NAS/cRIO03_data/ || 4byte Integer || 200 || 1.25e-6 [V/count] || .AD0[0-15] ||for Env. signal || || /NAS/PXI_data/5000Hz || 4byte Integer || 5000 || 5.525e-9 [V/count] || .AD0[0-3] || for Main strainmeter signal || || /NAS/PXI_data/50000Hz || 4byte Integer || 50000 || 5.525e-9 [V/count] || .AD0[0-3] || for Main strainmeter signal || || /data1/PHASE/50000Hz || 8byte float || 200 || 1 [strain] || .PHASE <<BR>> .STRAIN<<BR>>.ZOBUBN<<BR>>.SQRT || these are for the calculation of strain signal from the 50kHz PXI signal || || /data2/CLIO/LIN || 8byte float || 200 || 1 [strain] || .LIN || calculated strain signal || || /data2/CLIO/SHR || 8byte float || 200 || 1 [strain] || .SHR || calculated strain signal|| == Environmental Monitor of GIF == |
Line 8: | Line 18: |
|| Location || DAQ Name || Channel || Signal || File Location || ||<|12>X500 ||<|8>cRIO01 || CH0 || Temperature || 172.16.32.201:/NAS/cRIO01_data || || CH1 || Humidity || 172.16.32.201:/NAS/cRIO01_data || || CH2 || Pressure || 172.16.32.201:/NAS/cRIO01_data || || CH3 || Vaccum || 172.16.32.201:/NAS/cRIO01_data || || CH4 || PXI01 Power for 3.3V || 172.16.32.201:/NAS/cRIO01_data || || CH5 || PXI01 Power for 5.0V || 172.16.32.201:/NAS/cRIO01_data || || CH6 || PXI01 Power for +12V || 172.16.32.201:/NAS/cRIO01_data || || CH7 || PXI01 Power for -12V || 172.16.32.201:/NAS/cRIO01_data || ||<|4> PXI01 || CH0 || PD1|| 172.16.32.201:/NAS/PXI1_data/50000Hz || || CH1 || PD2 || 172.16.32.201:/NAS/PXI1_data/50000Hz || || CH2 || Laser Amplitude || 172.16.32.201:/NAS/PXI1_data/50000Hz || || CH3 || Laser Absorption || 172.16.32.201:/NAS/PXI1_data/50000Hz || ||<|8>X2000 ||<|8>cRIO01 || CH0 || Temperature || 172.16.32.201:/NAS/cRIO02_data || || CH1 || Humidity || 172.16.32.201:/NAS/cRIO02_data || || CH2 || Pressure || 172.16.32.201:/NAS/cRIO02_data || || CH3 || Vaccum || 172.16.32.201:/NAS/cRIO02_data || || CH4 || None || 172.16.32.201:/NAS/cRIO02_data || || CH5 || None || 172.16.32.201:/NAS/cRIO02_data || || CH6 || None || 172.16.32.201:/NAS/cRIO02_data || || CH7 || None || 172.16.32.201:/NAS/cRIO02_data || ||<|16>X1500 ||<|16>cRIO01 || CH0 || Trillium240 velocity EW || 172.16.32.201:/NAS/cRIO02_data || || CH1 || None || 172.16.32.201:/NAS/cRIO02_data || || CH2 || Trillium240 velocity NS || 172.16.32.201:/NAS/cRIO02_data || || CH3 || Trillium240 velocity UD || 172.16.32.201:/NAS/cRIO02_data || || CH4 || Trillium240 position EW || 172.16.32.201:/NAS/cRIO02_data || || CH5 || Trillium240 position NS || 172.16.32.201:/NAS/cRIO02_data || || CH6 || Trillium240 position UD || 172.16.32.201:/NAS/cRIO02_data || || CH7 || None || 172.16.32.201:/NAS/cRIO02_data || || CH8 || CMG3T velocity EW || 172.16.32.201:/NAS/cRIO02_data || || CH9 || CMG3T velocity NS || 172.16.32.201:/NAS/cRIO02_data || || CH10 || CMG3T velocity UD || 172.16.32.201:/NAS/cRIO02_data || || CH11 || None || 172.16.32.201:/NAS/cRIO02_data || || CH12 || CMG3T position EW || 172.16.32.201:/NAS/cRIO02_data || || CH13 || CMG3T position NS || 172.16.32.201:/NAS/cRIO02_data || || CH14 || CMG3T position UD || 172.16.32.201:/NAS/cRIO02_data || || CH15 || None || 172.16.32.201:/NAS/cRIO02_data || |
||<#FAAC58> Location ||<#FAAC58> DAQ Name ||<#FAAC58> Channel ||<#FAAC58> Signal || ||<|12>X500 ||<|8>cRIO01 || CH0 || Temperature || || CH1 || Humidity || || CH2 || Pressure || || CH3 || Vaccum || || CH4 || PXI01 Power for 3.3V || || CH5 || PXI01 Power for 5.0V || || CH6 || PXI01 Power for +12V || || CH7 || PXI01 Power for -12V || ||<|4> PXI01 || CH0 || PD1|| || CH1 || PD2 || || CH2 || Laser Amplitude || || CH3 || Laser Absorption || ||<#FAAC58> Location ||<#FAAC58> DAQ Name ||<#FAAC58> Channel ||<#FAAC58> Signal || ||<|8>X2000 ||<|8>cRIO02 || CH0 || Temperature || || CH1 || Humidity || || CH2 || Pressure || || CH3 || Vaccum || || CH4 || None || || CH5 || None || || CH6 || None || || CH7 || None || ||<#FAAC58> Location ||<#FAAC58> DAQ Name ||<#FAAC58> Channel ||<#FAAC58> Signal || ||<|16>X1500 ||<|16>cRIO03 || CH0 || Trillium240 velocity EW || || CH1 || None || || CH2 || Trillium240 velocity NS || || CH3 || Trillium240 velocity UD || || CH4 || Trillium240 position EW || || CH5 || Trillium240 position NS || || CH6 || Trillium240 position UD || || CH7 || None || || CH8 || CMG3T velocity EW || || CH9 || CMG3T velocity NS || || CH10 || CMG3T velocity UD || || CH11 || None || || CH12 || CMG3T position EW || || CH13 || CMG3T position NS || || CH14 || CMG3T position UD || || CH15 || None || |
Data Configuration
All files are under the "/YYYY/MM/DD/" directory and filename format is "YYMMDDhhmm.xxx", where .xxx is file extension.
Data Location |
data type |
Sampling Rate [Hz] |
Unit Conversion factor |
File extension |
Comment |
/NAS/cRIO01_data/ |
4byte Integer |
200 |
1.25e-6 [V/count] |
.AD0[0-7] |
for Env. signal |
/NAS/cRIO02_data/ |
4byte Integer |
200 |
1.25e-6 [V/count] |
.AD0[0-7] |
for Env. signal |
/NAS/cRIO03_data/ |
4byte Integer |
200 |
1.25e-6 [V/count] |
.AD0[0-15] |
for Env. signal |
/NAS/PXI_data/5000Hz |
4byte Integer |
5000 |
5.525e-9 [V/count] |
.AD0[0-3] |
for Main strainmeter signal |
/NAS/PXI_data/50000Hz |
4byte Integer |
50000 |
5.525e-9 [V/count] |
.AD0[0-3] |
for Main strainmeter signal |
/data1/PHASE/50000Hz |
8byte float |
200 |
1 [strain] |
.PHASE |
these are for the calculation of strain signal from the 50kHz PXI signal |
/data2/CLIO/LIN |
8byte float |
200 |
1 [strain] |
.LIN |
calculated strain signal |
/data2/CLIO/SHR |
8byte float |
200 |
1 [strain] |
.SHR |
calculated strain signal |
Environmental Monitor of GIF
Update Nov 15 2018, Miyo
Location |
DAQ Name |
Channel |
Signal |
X500 |
cRIO01 |
CH0 |
Temperature |
CH1 |
Humidity |
||
CH2 |
Pressure |
||
CH3 |
Vaccum |
||
CH4 |
PXI01 Power for 3.3V |
||
CH5 |
PXI01 Power for 5.0V |
||
CH6 |
PXI01 Power for +12V |
||
CH7 |
PXI01 Power for -12V |
||
PXI01 |
CH0 |
PD1 |
|
CH1 |
PD2 |
||
CH2 |
Laser Amplitude |
||
CH3 |
Laser Absorption |
||
Location |
DAQ Name |
Channel |
Signal |
X2000 |
cRIO02 |
CH0 |
Temperature |
CH1 |
Humidity |
||
CH2 |
Pressure |
||
CH3 |
Vaccum |
||
CH4 |
None |
||
CH5 |
None |
||
CH6 |
None |
||
CH7 |
None |
||
Location |
DAQ Name |
Channel |
Signal |
X1500 |
cRIO03 |
CH0 |
Trillium240 velocity EW |
CH1 |
None |
||
CH2 |
Trillium240 velocity NS |
||
CH3 |
Trillium240 velocity UD |
||
CH4 |
Trillium240 position EW |
||
CH5 |
Trillium240 position NS |
||
CH6 |
Trillium240 position UD |
||
CH7 |
None |
||
CH8 |
CMG3T velocity EW |
||
CH9 |
CMG3T velocity NS |
||
CH10 |
CMG3T velocity UD |
||
CH11 |
None |
||
CH12 |
CMG3T position EW |
||
CH13 |
CMG3T position NS |
||
CH14 |
CMG3T position UD |
||
CH15 |
None |