3881
Comment:
|
4347
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
=== Data Configuration === | <<TableOfContents(2)>> == DAQ System == ||<#E0F2F7> IP address ||<#E0F2F7> Name ||<#E0F2F7> Memo || || 172.16.32.219 || PxiSub || || || 172.16.32.202 || KAGRA-DATA || || || 172.16.32.210 || NAS || || == Data Configuration == |
Line 10: | Line 20: |
|| /data1/PHASE/50000Hz || 8byte float || 200 || 1 [strain] || .[PHASE|STRAIN|ZOBUBN|SQRT] || calculated strain signal from 50kHz PXI signal || | || /data1/PHASE/50000Hz || 8byte float || 200 || 1 [strain] || .PHASE <<BR>> .STRAIN<<BR>>.ZOBUBN<<BR>>.SQRT || these are for the calculation of strain signal from the 50kHz PXI signal || |
Line 14: | Line 24: |
=== Environmental Monitor of GIF === | == Environmental Monitor of GIF == |
Line 16: | Line 26: |
|| Location || DAQ Name || Channel || Signal || | ||<#FAAC58> Location ||<#FAAC58> DAQ Name ||<#FAAC58> Channel ||<#FAAC58> Signal || |
Line 29: | Line 39: |
||<|16>X1500 ||<|16>cRIO02 || CH0 || Trillium240 velocity EW || | ||<#FAAC58> Location ||<#FAAC58> DAQ Name ||<#FAAC58> Channel ||<#FAAC58> Signal || ||<|8>X2000 ||<|8>cRIO02 || CH0 || Temperature || || CH1 || Humidity || || CH2 || Pressure || || CH3 || Vaccum || || CH4 || None || || CH5 || None || || CH6 || None || || CH7 || None || ||<#FAAC58> Location ||<#FAAC58> DAQ Name ||<#FAAC58> Channel ||<#FAAC58> Signal || ||<|16>X1500 ||<|16>cRIO03 || CH0 || Trillium240 velocity EW || |
Line 45: | Line 65: |
||<|8>X2000 ||<|8>cRIO03 || CH0 || Temperature || || CH1 || Humidity || || CH2 || Pressure || || CH3 || Vaccum || || CH4 || None || || CH5 || None || || CH6 || None || || CH7 || None || |
DAQ System
IP address |
Name |
Memo |
172.16.32.219 |
|
|
172.16.32.202 |
KAGRA-DATA |
|
172.16.32.210 |
NAS |
|
Data Configuration
All files are under the "/YYYY/MM/DD/" directory and filename format is "YYMMDDhhmm.xxx", where .xxx is file extension.
Data Location |
data type |
Sampling Rate [Hz] |
Unit Conversion factor |
File extension |
Comment |
/NAS/cRIO01_data/ |
4byte Integer |
200 |
1.25e-6 [V/count] |
.AD0[0-7] |
for Env. signal |
/NAS/cRIO02_data/ |
4byte Integer |
200 |
1.25e-6 [V/count] |
.AD0[0-7] |
for Env. signal |
/NAS/cRIO03_data/ |
4byte Integer |
200 |
1.25e-6 [V/count] |
.AD0[0-15] |
for Env. signal |
/NAS/PXI_data/5000Hz |
4byte Integer |
5000 |
5.525e-9 [V/count] |
.AD0[0-3] |
for Main strainmeter signal |
/NAS/PXI_data/50000Hz |
4byte Integer |
50000 |
5.525e-9 [V/count] |
.AD0[0-3] |
for Main strainmeter signal |
/data1/PHASE/50000Hz |
8byte float |
200 |
1 [strain] |
.PHASE |
these are for the calculation of strain signal from the 50kHz PXI signal |
/data2/CLIO/LIN |
8byte float |
200 |
1 [strain] |
.LIN |
calculated strain signal |
/data2/CLIO/SHR |
8byte float |
200 |
1 [strain] |
.SHR |
calculated strain signal |
Environmental Monitor of GIF
Update Nov 15 2018, Miyo
Location |
DAQ Name |
Channel |
Signal |
X500 |
cRIO01 |
CH0 |
Temperature |
CH1 |
Humidity |
||
CH2 |
Pressure |
||
CH3 |
Vaccum |
||
CH4 |
PXI01 Power for 3.3V |
||
CH5 |
PXI01 Power for 5.0V |
||
CH6 |
PXI01 Power for +12V |
||
CH7 |
PXI01 Power for -12V |
||
PXI01 |
CH0 |
PD1 |
|
CH1 |
PD2 |
||
CH2 |
Laser Amplitude |
||
CH3 |
Laser Absorption |
||
Location |
DAQ Name |
Channel |
Signal |
X2000 |
cRIO02 |
CH0 |
Temperature |
CH1 |
Humidity |
||
CH2 |
Pressure |
||
CH3 |
Vaccum |
||
CH4 |
None |
||
CH5 |
None |
||
CH6 |
None |
||
CH7 |
None |
||
Location |
DAQ Name |
Channel |
Signal |
X1500 |
cRIO03 |
CH0 |
Trillium240 velocity EW |
CH1 |
None |
||
CH2 |
Trillium240 velocity NS |
||
CH3 |
Trillium240 velocity UD |
||
CH4 |
Trillium240 position EW |
||
CH5 |
Trillium240 position NS |
||
CH6 |
Trillium240 position UD |
||
CH7 |
None |
||
CH8 |
CMG3T velocity EW |
||
CH9 |
CMG3T velocity NS |
||
CH10 |
CMG3T velocity UD |
||
CH11 |
None |
||
CH12 |
CMG3T position EW |
||
CH13 |
CMG3T position NS |
||
CH14 |
CMG3T position UD |
||
CH15 |
None |