== Overview ==
|| '''Sensor''' || '''Use''' || '''Spec''' ||
||<|2>HMP155(Vaisala) [[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]] || Temperature || ||
|| Humidity || ||
||PTB110(Vaisala) [[https://www.vaisala.com/sites/default/files/documents/PTB110%20User%20Guide%20in%20English.pdf|(Manual)]] || Pressure || ||
|| Trillium 120QA [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]]|| seismic || ||
|| Trillium Compact || seismic || ||
|| Trillium 240 || seismic || ||
|| CMG3T || seismic || ||
= Environmental Sensors =
 {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。
 {*} 配置図を載せる。
== Sensors List ==
|| || '''Sensor''' || '''Use''' || '''Spec''' || '''DAQ<<FootNote(More detail information about cRIO is [[KAGRASubgroupsGIFDAQ|here]].)>> ''' ||
||<|3> Air Environmental Sensor<<BR>>[[KAGRA/Subgroups/GIF/EM/AirEnvironmentalSensors|(Detail)]] ||<|2>[[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]] HMP155(Vaisala) || Temperature || || cRIO, KAGRA CDS ||
|| Humidity || || cRIO, KAGRA CDS ||
|| [[https://www.vaisala.com/sites/default/files/documents/PTB110%20User%20Guide%20in%20English.pdf|(Manual)]] PTB110(Vaisala) || Pressure || || cRIO, KAGRA CDS ||
||<|2> KAGRA Seismometer <<BR>>[[KAGRA/Subgroups/GIF/EM/KAGRAseismometer|(Detail)]]|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]] Trillium 120QA|| seismic || || KAGRA CDS ||
|| [[https://www-iuem.univ-brest.fr/pops/attachments/1489|(Manual)]] Trillium Compact || seismic || || KAGRA CDS ||
||<|2> GIF Seismometer <<BR>>[[KAGRA/Subgroups/GIF/EM/GIFseismometer|(Detail)]] || [[https://www.passcal.nmt.edu/webfm_send/220|(Manual)]] Trillium 240 || seismic || || cRIO ||
|| [[https://www.guralp.com/documents/MAN-030-0001.pdf|(Manual)]] CMG3T || seismic || || cRIO ||
Line 13: Line 14:
== Deployment ==



== Reference ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9269| Envrionmental Air Sensors]]
-------

Environmental Sensors

  • {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。 {*} 配置図を載せる。

Sensors List

Sensor

Use

Spec

DAQ1

Air Environmental Sensor
(Detail)

(Manual) HMP155(Vaisala)

Temperature

cRIO, KAGRA CDS

Humidity

cRIO, KAGRA CDS

(Manual) PTB110(Vaisala)

Pressure

cRIO, KAGRA CDS

KAGRA Seismometer
(Detail)

(Manual) Trillium 120QA

seismic

KAGRA CDS

(Manual) Trillium Compact

seismic

KAGRA CDS

GIF Seismometer
(Detail)

(Manual) Trillium 240

seismic

cRIO

(Manual) CMG3T

seismic

cRIO


  1. More detail information about cRIO is here. (1)