= Environmental Sensor = = Environmental Sensors =
Line 4: Line 4:
|| '''Sensor''' || '''Use''' || '''Spec''' ||
||<|2>[[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]]HMP155(Vaisala) || Temperature || ||
|| Humidity || ||
|| [[https://www.vaisala.com/sites/default/files/documents/PTB110%20User%20Guide%20in%20English.pdf|(Manual)]]PTB110(Vaisala) || Pressure || ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]] Trillium 120QA|| seismic || ||
|| Trillium Compact || seismic || ||
|| Trillium 240 || seismic || ||
|| CMG3T || seismic || ||
 {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。

== Sensors List ==
||
|| '''Sensor''' || '''Use''' || '''Spec''' || '''DAQ<<FootNote(More detail information about cRIO is [[KAGRASubgroupsGIFDAQ|here]].)>> ''' ||
||<|3> Air Environmental Sensor<<BR>>[[KAGRA/Subgroups/GIF/EM/AirEnvironmentalSensors|(Detail)]] ||<|2>[[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]] HMP155(Vaisala) || Temperature || || cRIO, KAGRA CDS ||
|| Humidity ||  || cRIO, KAGRA CDS ||
|| [[https://www.vaisala.com/sites/default/files/documents/PTB110%20User%20Guide%20in%20English.pdf|(Manual)]] PTB110(Vaisala) || Pressure || || cRIO, KAGRA CDS ||
||<|2> KAGRA Seismometer <<BR>>[[KAGRA/Subgroups/GIF/EM/KAGRAseismometer|(Detail)]]|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]] Trillium 120QA|| seismic || || KAGRA CDS ||
|| [[https://www-iuem.univ-brest.fr/pops/attachments/1489|(Manual)]] Trillium Compact || seismic || || KAGRA CDS ||
||<|2> GIF Seismometer <<BR>>[[KAGRA/Subgroups/GIF/EM/GIFseismometer|(Detail)]] || [[https://www.passcal.nmt.edu/webfm_send/220|(Manual)]] Trillium 240 || seismic || || cRIO ||
|| [[https://www.guralp.com/documents/MAN-030-0001.pdf|(Manual)]] CMG3T || seismic || || cRIO ||
Line 15: Line 18:
 {*} 配置図を載せる。
Line 16: Line 20:
== Circuit ==

 {*} アンプの回路図、Dsubの配線図等のJGWのリンクを載せる。

== Calibration ==
cRIO01 500m, y[V]がADの電圧値。上からAD00,01,02,03
{{{
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=-y[V]/5*100/2
p[hPa]=-y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]
}}}
cRIO02 2000m
{{{
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=y[V]/5*100/2
p[hPa]=y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]
}}}
Line 19: Line 42:

-------

Environmental Sensors

Overview

  • {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。

Sensors List

Sensor

Use

Spec

DAQ1

Air Environmental Sensor
(Detail)

(Manual) HMP155(Vaisala)

Temperature

cRIO, KAGRA CDS

Humidity

cRIO, KAGRA CDS

(Manual) PTB110(Vaisala)

Pressure

cRIO, KAGRA CDS

KAGRA Seismometer
(Detail)

(Manual) Trillium 120QA

seismic

KAGRA CDS

(Manual) Trillium Compact

seismic

KAGRA CDS

GIF Seismometer
(Detail)

(Manual) Trillium 240

seismic

cRIO

(Manual) CMG3T

seismic

cRIO

Deployment

  • {*} 配置図を載せる。

Circuit

  • {*} アンプの回路図、Dsubの配線図等のJGWのリンクを載せる。

Calibration

cRIO01 500m, y[V]がADの電圧値。上からAD00,01,02,03

t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=-y[V]/5*100/2
p[hPa]=-y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]

cRIO02 2000m

t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=y[V]/5*100/2
p[hPa]=y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]