160
Comment:
|
1890
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
= Environmental Monitor = == OverView == |
<<TableOfContents(3)>> = Environmental Sensors = == Overview == {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。 |
Line 4: | Line 6: |
|| Sensor || Use || Spec || || ||<|2>HMP155 || Temperature || || || || Humidity || || || || Pressure || || |
== Sensors List == ||''' a ''' || '''Sensor''' || '''Use''' || '''Spec''' || '''DAQ<<FootNote(More detail information about cRIO is [[KAGRASubgroupsGIFDAQ|here]].)>> ''' || ||<|3> Air Environment||<|2>[[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]] HMP155(Vaisala) || Temperature || || cRIO, KAGRA CDS || || Humidity || || cRIO, KAGRA CDS || ||<|2>for KAGRA || [[https://www.vaisala.com/sites/default/files/documents/PTB110%20User%20Guide%20in%20English.pdf|(Manual)]] PTB110(Vaisala) || Pressure || || cRIO, KAGRA CDS || || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]] Trillium 120QA|| seismic || || KAGRA CDS || || || [[https://www-iuem.univ-brest.fr/pops/attachments/1489|(Manual)]] Trillium Compact || seismic || || KAGRA CDS || || || [[https://www.passcal.nmt.edu/webfm_send/220|(Manual)]] Trillium 240 || seismic || || cRIO || || || [[https://www.guralp.com/documents/MAN-030-0001.pdf|(Manual)]] CMG3T || seismic || || cRIO || == Deployment == {*} 配置図を載せる。 == Circuit == {*} アンプの回路図、Dsubの配線図等のJGWのリンクを載せる。 == Calibration == cRIO01 500m, y[V]がADの電圧値。上からAD00,01,02,03 {{{ t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0 h[%]=-y[V]/5*100/2 p[hPa]=-y[V]/2/5*(1100-800)+800 vac[Pa]=10^[2*y[V]-13.0] }}} cRIO02 2000m {{{ t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0 h[%]=y[V]/5*100/2 p[hPa]=y[V]/2/5*(1100-800)+800 vac[Pa]=10^[2*y[V]-13.0] }}} == Reference == [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9269| Envrionmental Air Sensors]] ------- |
Environmental Sensors
Overview
ひずみ計に対する各センサーをプロジェクションしたASDを載せる。
Sensors List
a |
Sensor |
Use |
Spec |
DAQ1 |
Air Environment |
(Manual) HMP155(Vaisala) |
Temperature |
|
cRIO, KAGRA CDS |
Humidity |
|
cRIO, KAGRA CDS |
||
for KAGRA |
(Manual) PTB110(Vaisala) |
Pressure |
|
cRIO, KAGRA CDS |
(Manual) Trillium 120QA |
seismic |
|
KAGRA CDS |
|
|
(Manual) Trillium Compact |
seismic |
|
KAGRA CDS |
|
(Manual) Trillium 240 |
seismic |
|
cRIO |
|
(Manual) CMG3T |
seismic |
|
cRIO |
Deployment
配置図を載せる。
Circuit
アンプの回路図、Dsubの配線図等のJGWのリンクを載せる。
Calibration
cRIO01 500m, y[V]がADの電圧値。上からAD00,01,02,03
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0 h[%]=-y[V]/5*100/2 p[hPa]=-y[V]/2/5*(1100-800)+800 vac[Pa]=10^[2*y[V]-13.0]
cRIO02 2000m
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0 h[%]=y[V]/5*100/2 p[hPa]=y[V]/2/5*(1100-800)+800 vac[Pa]=10^[2*y[V]-13.0]
Reference