Differences between revisions 61 and 71 (spanning 10 versions)
Revision 61 as of 2018-11-15 15:13:53
Size: 2064
Editor: KousekiMiyo
Comment:
Revision 71 as of 2018-11-15 15:23:55
Size: 1449
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
<<TableOfContents(3)>>
Line 3: Line 2:
== Overview ==
{*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。
 * {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。
 * {*} 配置図を載せる。
Line 6: Line 5:
== Sensors List ==
|| || '''Sensor''' ||
'''Use''' || '''Spec''' || '''DAQ<<FootNote(More detail information about cRIO is [[KAGRASubgroupsGIFDAQ|here]].)>> ''' || ''' Purpose ''' ||
||<|3> Air Environmental Monitor<\br>a ||<|2>[[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]] HMP155(Vaisala) || Temperature || || cRIO, KAGRA CDS ||<|3>Air Envrionment ||
|| <#F0F0FF> || <#F0F0FF>'''Sensor''' || <#F0F0FF>'''Use''' || <#F0F0FF>'''Spec''' || <#F0F0FF>'''DAQ<<FootNote(More detail information about cRIO is [[KAGRASubgroupsGIFDAQ|here]].)>> ''' ||
||<|3> Air Environmental Sensor<<BR>>[[KAGRA/Subgroups/GIF/EM/AirEnvironmentalSensors|(Detail)]] ||<|2>[[https://www.vaisala.com/sites/default/files/documents/HMP155_User_Guide_in_English.pdf|(Manual)]] HMP155(Vaisala) || Temperature || || cRIO, KAGRA CDS ||
Line 11: Line 9:
||<|2> KAGRA Seismometer || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]] Trillium 120QA|| seismic || || KAGRA CDS ||<|2>Seismic noise on the '''both ends and Center''' station || ||<|2> KAGRA Seismometer <<BR>>[[KAGRA/Subgroups/GIF/EM/KAGRAseismometer|(Detail)]]|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7554|(Manual)]] Trillium 120QA|| seismic || || KAGRA CDS ||
Line 13: Line 11:
||<|2> GIF Seismometer || [[https://www.passcal.nmt.edu/webfm_send/220|(Manual)]] Trillium 240 || seismic || || cRIO ||<|2>Seismic noise on the '''X Arm''' || ||<|2> GIF Seismometer <<BR>>[[KAGRA/Subgroups/GIF/EM/GIFseismometer|(Detail)]] || [[https://www.passcal.nmt.edu/webfm_send/220|(Manual)]] Trillium 240 || seismic || || cRIO ||
Line 16: Line 14:
== Deployment ==

 {*} 配置図を載せる。

== Circuit ==

 {*} アンプの回路図、Dsubの配線図等のJGWのリンクを載せる。

== Calibration ==
cRIO01 500m, y[V]がADの電圧値。上からAD00,01,02,03
{{{
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=-y[V]/5*100/2
p[hPa]=-y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]
}}}
cRIO02 2000m
{{{
t[℃]=(y[V]/10/(1+3300/430)/1.e-3-107.79)/.388+20.0
h[%]=y[V]/5*100/2
p[hPa]=y[V]/2/5*(1100-800)+800
vac[Pa]=10^[2*y[V]-13.0]
}}}

== Reference ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9269| Envrionmental Air Sensors]]

Environmental Sensors

  • {*} ひずみ計に対する各センサーをプロジェクションしたASDを載せる。

  • {*} 配置図を載せる。

<#F0F0FF>

<#F0F0FF>Sensor

<#F0F0FF>Use

<#F0F0FF>Spec

<#F0F0FF>DAQ1

Air Environmental Sensor
(Detail)

(Manual) HMP155(Vaisala)

Temperature

cRIO, KAGRA CDS

Humidity

cRIO, KAGRA CDS

(Manual) PTB110(Vaisala)

Pressure

cRIO, KAGRA CDS

KAGRA Seismometer
(Detail)

(Manual) Trillium 120QA

seismic

KAGRA CDS

(Manual) Trillium Compact

seismic

KAGRA CDS

GIF Seismometer
(Detail)

(Manual) Trillium 240

seismic

cRIO

(Manual) CMG3T

seismic

cRIO


  1. More detail information about cRIO is here. (1)

KAGRA/Subgroups/GIF/EM (last edited 2018-11-20 07:43:38 by KousekiMiyo)