835
Comment:
|
1080
|
Deletions are marked like this. | Additions are marked like this. |
Line 3: | Line 3: |
MC front: 1.2 x 2.4m (close to MCF chamber; beam height=1.134m) |
MC front: 1.2 x 2.4m x h 0.99m (close to MCF chamber; beam height=1.134m - 0.012m) |
Line 6: | Line 6: |
MCT: 1m x 1m (close to MCE chamber; beam height=1.149m) |
MCT: 1m x 1m x h 0.99m (close to MCE chamber; beam height=1.149m - 0.027m) |
Line 9: | Line 9: |
REFL: 1.2 x 2.4m (close to IFI chamber; beam height=1.141m) |
REFL: 1.2 x 2.4m x h 0.99m (close to IFI chamber; beam height=1.141m - 0.019m) |
Line 12: | Line 12: |
IMMT2: 1m x 1m (temporary) (close to IFI chamber; beam height=1.141m) |
IMMT2: 1m x 1m x h 0.99m (temporary) (close to IFI chamber; beam height=1.141m - 0.019m) |
Line 15: | Line 15: |
SR2: 1m x 1m (temporary for iKAGRA AS) | SR2: 1m x 1m x h 1m (temporary for iKAGRA AS) |
Line 18: | Line 18: |
ETMX: 1m x 1m (temporary) (close to EXC chamber; beam height=1.400m) |
ETMX: 1m x 1m x h 1m (temporary) (close to EXA chamber; beam height=1.200m) |
Line 21: | Line 21: |
ETMY: 1m x 1m (temporary) (close to EYC chamber; beam height=1.400m) |
ETMY: 1m x 1m x h 1m (temporary) (close to EYA chamber; beam height=1.200m) |
Line 25: | Line 25: |
POX: 1m x 1m (close to SR3 chamber; beam height=) |
POX: 1m x 1m x h 1m (temporary) (close to SR3 chamber; beam height=1.257m) |
Line 28: | Line 28: |
POY: 1m x 1m (close to PR3 chamber; beam height=) |
POY: 1m x 1m x h 1m (temporary) (close to PR3 chamber; beam height=1.150m) |
Line 31: | Line 31: |
POP: 1.2 x 2.4m (close to PR2 chamber; beam height=) |
POP: 1.2 x 2.4m x h 1m (close to PR2 chamber; beam height=1.184m) |
Line 34: | Line 34: |
POS: 1.2 x 2.4m (close to ??? chamber; beam height=) |
POS: 1.2 x 2.4m x h 1m (close to SR2 chamber; beam height=1.217m) |
Line 37: | Line 37: |
AS: 1.2 x 2.4m (close to SRM chamber; beam height=) |
AS: 1.2 x 2.4m x h 1 (close to SRM chamber; beam height=1.271m) * Beam height written here is from the mortar surface. |
KAGRA Output Optical Tables
iKAGRA
MC front: 1.2 x 2.4m x h 0.99m (close to MCF chamber; beam height=1.134m - 0.012m)
MCT: 1m x 1m x h 0.99m (close to MCE chamber; beam height=1.149m - 0.027m)
REFL: 1.2 x 2.4m x h 0.99m (close to IFI chamber; beam height=1.141m - 0.019m)
IMMT2: 1m x 1m x h 0.99m (temporary) (close to IFI chamber; beam height=1.141m - 0.019m)
SR2: 1m x 1m x h 1m (temporary for iKAGRA AS) (close to SR2 chamber; beam height=1.217m)
ETMX: 1m x 1m x h 1m (temporary) (close to EXA chamber; beam height=1.200m)
ETMY: 1m x 1m x h 1m (temporary) (close to EYA chamber; beam height=1.200m)
bKAGRA
POX: 1m x 1m x h 1m (temporary) (close to SR3 chamber; beam height=1.257m)
POY: 1m x 1m x h 1m (temporary) (close to PR3 chamber; beam height=1.150m)
POP: 1.2 x 2.4m x h 1m (close to PR2 chamber; beam height=1.184m)
POS: 1.2 x 2.4m x h 1m (close to SR2 chamber; beam height=1.217m)
AS: 1.2 x 2.4m x h 1 (close to SRM chamber; beam height=1.271m)
* Beam height written here is from the mortar surface.