1081
Comment:
|
2375
|
Deletions are marked like this. | Additions are marked like this. |
Line 3: | Line 3: |
MC front: 1.2 x 2.4m x h 0.99m (close to MCF chamber; beam height=1.134m - 0.012m) MCT: 1m x 1m x h 0.99m (close to MCE chamber; beam height=1.149m - 0.027m) REFL: 1.2 x 2.4m x h 0.99m (close to IFI chamber; beam height=1.141m - 0.019m) IMMT2: 1m x 1m x h 0.99m (temporary) (close to IFI chamber; beam height=1.141m - 0.019m) SR2: 1m x 1m x h 1m (temporary for iKAGRA AS) (close to SR2 chamber; beam height=1.217m) ETMX: 1m x 1m x h 1m (temporary) (close to EXA chamber; beam height=1.200m) ETMY: 1m x 1m x h 1m (temporary) (close to EYA chamber; beam height=1.200m) |
||name ||size and height ||closest chamber ||beam height ||optical layout drawing / status || ||IMC REFL|| 1m x 1m x h 0.940m (CL-1010TS) ||MCF chamber || 1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed|| ||MCT || 1m x 1m x h 0.955m ||MCE chamber || 1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10), installed|| ||REFL || 1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber || 1.141m - 0.019m ||VIS is borrowing now, to be used for POX (or POY) for bKAGRA, purchased(2015/9) || ||IMMT1T || 300mm x 400mm (breadboard on pylon) ||MMT chamber ||??? ||??? || |
Line 25: | Line 10: |
POX: 1m x 1m x h 1m (temporary) (close to SR3 chamber; beam height=1.257m) POY: 1m x 1m x h 1m (temporary) (close to PR3 chamber; beam height=1.150m) POP: 1.2 x 2.4m x h 1m (close to PR2 chamber; beam height=1.184m) POS: 1.2 x 2.4m x h 1m (close to SR2 chamber; beam height=1.217m) AS: 1.2 x 2.4m x h 1m (close to SRM chamber; beam height=1.271m) |
||name ||size and height ||closest chamber ||beam height || || ||IMC REFL|| 1.2 x 2.4m x h 0.940m ||MCF chamber || 1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10)|| ||REFL || 1.2 x 2.4m x h 0.947m ||IFI chamber || 1.141m - 0.019m ||used at Kashiwa for now, purchased(2015/9)|| ||IMMT2 || 1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber || 1.141m - 0.019m ||VIS is borrowing now, purchased(2014/10)|| ||ETMX || 1m x 1m x h 0.986m (CL-1010TS) ||EXA chamber || 1.200m || may use bigger table instead|| ||ETMY || 1m x 1m x h 0.986m (CL-1010TS) ||EYA chamber || 1.200m || may use bigger table instead|| ||POX || 1m x 1m x h 1.043m (CL-1010TS) || SR3 chamber || 1.257m ||used for REFL in iKAGRA, purchased(2015/9)|| ||POY || 1m x 1m x h 0.936m (CL-1010TS) || PR3 chamber || 1.150m ||used for IMC REFL in iKAGRA, purchased(2015/9)|| ||POP || 1.2 x 2.4m x h 0.970m || PR2 chamber || 1.184m || || ||POS || 1.2 x 2.4m x h 1.000m || SR2 chamber || 1.217m || || ||AS || 1.2 x 2.4m x h 1.000m || SRM chamber || 1.271m || || |
Line 42: | Line 23: |
* Mortar thickness is about 20mm by design. * Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m) * See [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=2607|JGW-D1402607]] * iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson |
KAGRA Output Optical Tables
iKAGRA
name |
size and height |
closest chamber |
beam height |
optical layout drawing / status |
IMC REFL |
1m x 1m x h 0.940m (CL-1010TS) |
MCF chamber |
1.134m - 0.012m |
JGW-D1503412 / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed |
MCT |
1m x 1m x h 0.955m |
MCE chamber |
1.149m - 0.027m |
JGW-D1503412 / purchased(2014/10), installed |
REFL |
1m x 1m x h 0.947m (CL-1010TS) |
IFI chamber |
1.141m - 0.019m |
VIS is borrowing now, to be used for POX (or POY) for bKAGRA, purchased(2015/9) |
IMMT1T |
300mm x 400mm (breadboard on pylon) |
MMT chamber |
??? |
??? |
bKAGRA
name |
size and height |
closest chamber |
beam height |
|
IMC REFL |
1.2 x 2.4m x h 0.940m |
MCF chamber |
1.134m - 0.012m |
JGW-D1503412 / purchased(2014/10) |
REFL |
1.2 x 2.4m x h 0.947m |
IFI chamber |
1.141m - 0.019m |
used at Kashiwa for now, purchased(2015/9) |
IMMT2 |
1m x 1m x h 0.947m (CL-1010TS) |
IFI chamber |
1.141m - 0.019m |
VIS is borrowing now, purchased(2014/10) |
ETMX |
1m x 1m x h 0.986m (CL-1010TS) |
EXA chamber |
1.200m |
may use bigger table instead |
ETMY |
1m x 1m x h 0.986m (CL-1010TS) |
EYA chamber |
1.200m |
may use bigger table instead |
POX |
1m x 1m x h 1.043m (CL-1010TS) |
SR3 chamber |
1.257m |
used for REFL in iKAGRA, purchased(2015/9) |
POY |
1m x 1m x h 0.936m (CL-1010TS) |
PR3 chamber |
1.150m |
used for IMC REFL in iKAGRA, purchased(2015/9) |
POP |
1.2 x 2.4m x h 0.970m |
PR2 chamber |
1.184m |
|
POS |
1.2 x 2.4m x h 1.000m |
SR2 chamber |
1.217m |
|
AS |
1.2 x 2.4m x h 1.000m |
SRM chamber |
1.271m |
|
* Beam height written here is from the mortar surface.
* Mortar thickness is about 20mm by design.
* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m)
* See JGW-D1402607
* iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson