KAGRA Output Optical Tables
iKAGRA
Name |
size |
closest chamber |
beam height |
MC front |
1.2 x 2.4m x h 0.940m |
MCF chamber |
1.134m - 0.012m |
MCT |
1m x 1m x h 0.955m |
MCE chamber |
1.149m - 0.027m |
REFL |
1.2 x 2.4m x h 0.947m |
IFI chamber |
1.141m - 0.019m |
IMMT2 |
1m x 1m x h 0.947m (temporary) |
IFI chamber |
1.141m - 0.019m |
SR2 |
1m x 1m x h 1.000m (temporary for iKAGRA AS) |
SR2 chamber |
1.217m |
ETMX |
1m x 1m x h 0.986m (temporary) |
EXA chamber |
1.200m |
ETMY |
1m x 1m x h 0.986m (temporary) |
EYA chamber |
1.200m |
bKAGRA
Name |
size |
closest chamber |
beam height |
POX |
1m x 1m x h 1.043m (temporary) |
SR3 chamber |
1.257m |
POY |
1m x 1m x h 0.936m (temporary) |
PR3 chamber |
1.150m |
POP |
1.2 x 2.4m x h 0.970m |
PR2 chamber |
1.184m |
POS |
1.2 x 2.4m x h 1.000m |
SR2 chamber |
1.217m |
AS |
1.2 x 2.4m x h 1.000m |
SRM chamber |
1.271m |
* Beam height written here is from the mortar surface.
* Mortar thickness is about 20mm by design.
* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m)
* See JGW-D1402607