MC front: 1.2 x 2.4m
(close to MCF chamber)

MCT: 1m x 1m
(close to MCE chamber)

REFL: 1.2 x 2.4m
(close to IFI chamber)

POX: 1m x 1m
(close to ??? chamber)

IMMT2: 1m x 1m (temporary)
(close to IFI chamber)

SR2: 1m x 1m (temporary for iKAGRA AS)
(close to SR2 chamber)

ETMX: 1m x 1m (temporary)
(close to EXA chamber)

ETMY: 1m x 1m (temporary)
(close to EYA chamber)
||name ||size and height ||closest chamber ||beam height ||optical layout drawing / status ||
||MC front || 1.2 x 2.4m x h 0.940m ||MCF chamber || 1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10)||
||MCT || 1m x 1m x h 0.955m ||MCE chamber || 1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10)||
||REFL || 1m x 1m x h 0.947m (temporary) ||IFI chamber || 1.141m - 0.019m ||to be used for POX (or POY) for bKAGRA, purchased(2015/9) ||
||IMMT2 || 1m x 1m x h 0.947m (temporary) ||IFI chamber || 1.141m - 0.019m ||purchased(2014/10) ||
Line 28: Line 10:
POY: 1m x 1m
(close to ??? chamber)
||name ||size and height ||closest chamber ||beam height || ||
||REFL || 1.2 x 2.4m x h 0.947m ||IFI chamber || 1.141m - 0.019m ||used at Kashiwa for now, purchased(2015/9)||
||ETMX || 1m x 1m x h 0.986m (temporary) ||EXA chamber || 1.200m || may use bigger table instead||
||ETMY || 1m x 1m x h 0.986m (temporary) ||EYA chamber || 1.200m || may use bigger table instead||
||POX || 1m x 1m x h 1.043m (temporary) || SR3 chamber || 1.257m ||used for REFL in iKAGRA, purchased(2015/9)||
||POY || 1m x 1m x h 0.936m (temporary) || PR3 chamber || 1.150m ||purchased(2015/9)||
||POP || 1.2 x 2.4m x h 0.970m || PR2 chamber || 1.184m || ||
||POS || 1.2 x 2.4m x h 1.000m || SR2 chamber || 1.217m || ||
||AS || 1.2 x 2.4m x h 1.000m || SRM chamber || 1.271m || ||
Line 31: Line 20:
POP: 1.2 x 2.4m
(close to PR3 chamber)
* Beam height written here is from the mortar surface.
Line 34: Line 22:
POS: 1.2 x 2.4m
(close to ??? chamber)
* Mortar thickness is about 20mm by design.
Line 37: Line 24:
AS: 1.2 x 2.4m
(close to EYA chamber)
* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m)

* See [[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/DocDB/ShowDocument?docid=2607|JGW-D1402607]]

* iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson

KAGRA Output Optical Tables

iKAGRA

name

size and height

closest chamber

beam height

optical layout drawing / status

MC front

1.2 x 2.4m x h 0.940m

MCF chamber

1.134m - 0.012m

JGW-D1503412 / purchased(2014/10)

MCT

1m x 1m x h 0.955m

MCE chamber

1.149m - 0.027m

JGW-D1503412 / purchased(2014/10)

REFL

1m x 1m x h 0.947m (temporary)

IFI chamber

1.141m - 0.019m

to be used for POX (or POY) for bKAGRA, purchased(2015/9)

IMMT2

1m x 1m x h 0.947m (temporary)

IFI chamber

1.141m - 0.019m

purchased(2014/10)

bKAGRA

name

size and height

closest chamber

beam height

REFL

1.2 x 2.4m x h 0.947m

IFI chamber

1.141m - 0.019m

used at Kashiwa for now, purchased(2015/9)

ETMX

1m x 1m x h 0.986m (temporary)

EXA chamber

1.200m

may use bigger table instead

ETMY

1m x 1m x h 0.986m (temporary)

EYA chamber

1.200m

may use bigger table instead

POX

1m x 1m x h 1.043m (temporary)

SR3 chamber

1.257m

used for REFL in iKAGRA, purchased(2015/9)

POY

1m x 1m x h 0.936m (temporary)

PR3 chamber

1.150m

purchased(2015/9)

POP

1.2 x 2.4m x h 0.970m

PR2 chamber

1.184m

POS

1.2 x 2.4m x h 1.000m

SR2 chamber

1.217m

AS

1.2 x 2.4m x h 1.000m

SRM chamber

1.271m

* Beam height written here is from the mortar surface.

* Mortar thickness is about 20mm by design.

* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m)

* See JGW-D1402607

* iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson