1730
Comment:
|
2485
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
||MC front || 1.2 x 2.4m x h 0.940m ||MCF chamber || 1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3301|JGW-D1503301]] / purchased(2014/10)|| ||MCT || 1m x 1m x h 0.955m ||MCE chamber || 1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3301|JGW-D1503301]] / purchased(2014/10)|| ||REFL || 1.2 x 2.4m x h 0.947m ||IFI chamber || 1.141m - 0.019m || || ||IMMT2 || 1m x 1m x h 0.947m (temporary) ||IFI chamber || 1.141m - 0.019m ||purchased(2014/10) || |
||IMC REFL ||1m x 1m x h 0.940m (CL-1010TS) ||MCF chamber ||1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed || ||MCT ||1m x 1m x h 0.955m ||MCE chamber ||1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10), installed || ||REFL ||1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber ||1.141m - 0.019m ||to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2) || ||IMMT1T ||250mm x 300mm (breadboard on pylon) ||MMT chamber ||??? ||installed([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=862|klog #862]]) || |
Line 11: | Line 12: |
||ETMX || 1m x 1m x h 0.986m (temporary) ||EXA chamber || 1.200m || may use bigger table instead|| ||ETMY || 1m x 1m x h 0.986m (temporary) ||EYA chamber || 1.200m || may use bigger table instead|| ||POX || 1m x 1m x h 1.043m (temporary) || SR3 chamber || 1.257m || || ||POY || 1m x 1m x h 0.936m (temporary) || PR3 chamber || 1.150m || || ||POP || 1.2 x 2.4m x h 0.970m || PR2 chamber || 1.184m || || ||POS || 1.2 x 2.4m x h 1.000m || SR2 chamber || 1.217m || || ||AS || 1.2 x 2.4m x h 1.000m || SRM chamber || 1.271m || || |
||IMC REFL ||1.2 x 2.4m x h 0.940m ||MCF chamber ||1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10) || ||REFL ||1.2 x 2.4m x h 0.947m ||IFI chamber ||1.141m - 0.019m ||used at Kashiwa for now, purchased(2015/9) || ||IMMT2 ||1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber ||1.141m - 0.019m ||VIS is borrowing now, purchased(2014/10) || ||ETMX ||1m x 1m x h 0.986m (CL-1010TS) ||EXT chamber ||1.200m ||may use bigger table instead || ||ETMY ||1m x 1m x h 0.986m (CL-1010TS) ||EYT chamber ||1.200m ||may use bigger table instead || ||POX ||1m x 1m x h 1.043m (CL-1010TS) ||SR3 chamber ||1.257m ||used for REFL in iKAGRA, purchased(2015/9) || ||POY ||1m x 1m x h 0.936m (CL-1010TS) ||PR3 chamber ||1.150m ||used for IMC REFL in iKAGRA, purchased(2015/9) || ||POP ||1.2 x 2.4m x h 0.970m ||PR2 chamber ||1.184m ||reuse iKAGRA PSL table (h 0.9645m) instead of buying a new one|| ||POS ||1.2 x 2.4m x h 1.000m ||SR2 chamber ||1.217m || || ||AS ||1.2 x 2.4m x h 1.000m ||SRM chamber ||1.271m || || |
KAGRA Output Optical Tables
iKAGRA
name |
size and height |
closest chamber |
beam height |
optical layout drawing / status |
IMC REFL |
1m x 1m x h 0.940m (CL-1010TS) |
MCF chamber |
1.134m - 0.012m |
JGW-D1503412 / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed |
MCT |
1m x 1m x h 0.955m |
MCE chamber |
1.149m - 0.027m |
JGW-D1503412 / purchased(2014/10), installed |
REFL |
1m x 1m x h 0.947m (CL-1010TS) |
IFI chamber |
1.141m - 0.019m |
to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2) |
IMMT1T |
250mm x 300mm (breadboard on pylon) |
MMT chamber |
??? |
installed(klog #862) |
bKAGRA
name |
size and height |
closest chamber |
beam height |
|
IMC REFL |
1.2 x 2.4m x h 0.940m |
MCF chamber |
1.134m - 0.012m |
JGW-D1503412 / purchased(2014/10) |
REFL |
1.2 x 2.4m x h 0.947m |
IFI chamber |
1.141m - 0.019m |
used at Kashiwa for now, purchased(2015/9) |
IMMT2 |
1m x 1m x h 0.947m (CL-1010TS) |
IFI chamber |
1.141m - 0.019m |
VIS is borrowing now, purchased(2014/10) |
ETMX |
1m x 1m x h 0.986m (CL-1010TS) |
EXT chamber |
1.200m |
may use bigger table instead |
ETMY |
1m x 1m x h 0.986m (CL-1010TS) |
EYT chamber |
1.200m |
may use bigger table instead |
POX |
1m x 1m x h 1.043m (CL-1010TS) |
SR3 chamber |
1.257m |
used for REFL in iKAGRA, purchased(2015/9) |
POY |
1m x 1m x h 0.936m (CL-1010TS) |
PR3 chamber |
1.150m |
used for IMC REFL in iKAGRA, purchased(2015/9) |
POP |
1.2 x 2.4m x h 0.970m |
PR2 chamber |
1.184m |
reuse iKAGRA PSL table (h 0.9645m) instead of buying a new one |
POS |
1.2 x 2.4m x h 1.000m |
SR2 chamber |
1.217m |
|
AS |
1.2 x 2.4m x h 1.000m |
SRM chamber |
1.271m |
|
* Beam height written here is from the mortar surface.
* Mortar thickness is about 20mm by design.
* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m)
* See JGW-D1402607
* iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson