Differences between revisions 34 and 56 (spanning 22 versions)
Revision 34 as of 2015-09-12 10:22:37
Size: 1730
Comment:
Revision 56 as of 2016-11-14 11:35:54
Size: 2786
Comment:
Deletions are marked like this. Additions are marked like this.
Line 4: Line 4:
||MC front || 1.2 x 2.4m x h 0.940m ||MCF chamber || 1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10)||
||MCT || 1m x 1m x h 0.955m ||MCE chamber || 1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10)||
||REFL || 1.2 x 2.4m x h 0.947m ||IFI chamber || 1.141m - 0.019m || ||
||IMMT2 || 1m x 1m x h 0.947m (temporary) ||IFI chamber || 1.141m - 0.019m ||purchased(2014/10) ||
||IMC REFL ||1m x 1m x h 0.940m (CL-1010TS) ||MCF chamber ||1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed ||
||MCT ||1m x 1m x h 0.955m ||MCE chamber ||1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10), installed ||
||REFL ||1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber ||1.141m - 0.019m ||to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2) ||
||IMMT1T ||300mm x 400mm + extension(250mm x 300mm) (breadboard on pylon) ||MMT chamber ||??? ||installed([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=862|klog #862]]) ||
Line 11: Line 12:
||ETMX || 1m x 1m x h 0.986m (temporary) ||EXA chamber || 1.200m || may use bigger table instead||
||ETMY || 1m x 1m x h 0.986m (temporary) ||EYA chamber || 1.200m || may use bigger table instead||
||POX || 1m x 1m x h 1.043m (temporary) || SR3 chamber || 1.257m || ||
||POY || 1m x 1m x h 0.936m (temporary) || PR3 chamber || 1.150m || ||
||POP || 1.2 x 2.4m x h 0.970m || PR2 chamber || 1.184m || ||
||POS || 1.2 x 2.4m x h 1.000m || SR2 chamber || 1.217m || ||
||AS || 1.2 x 2.4m x h 1.000m || SRM chamber || 1.271m || ||
||IMC REFL ||1.2m x 2.4m x h 0.940m ||MCF chamber -Y ||1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10) ||
||REFL ||1.2m x 2.4m x h 0.947m ||IFI chamber -Y ||1.141m - 0.019m ||used at Kashiwa for now, purchased(2015/9) ||
||IMMT2 ||1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber +Y ||1.141m - 0.019m ||VIS is borrowing now, purchased(2014/10) ||
||ETMX ||1.2m x 2.0m x h 1.006m ||EXT chamber +X (table is put on mortar surface) ||1.200m ||size confirmed(2016/7/11) ||
||ETMY ||1.2m x 2.0m x h 1.006m ||EYT chamber +Y (table is put on mortar surface) ||1.200m ||size confirmed(2016/7/11) ||
||POX ||1m x 1m x h 1.043m (CL-1010TS) ||SR3 chamber (no isolation cutting for tables) ||1.257m ||used for REFL in iKAGRA, purchased(2015/9) ||
||POY ||1m x 1m x h 0.936m (CL-1010TS) ||PR3 chamber -Y ||1.150m ||used for IMC REFL in iKAGRA, purchased(2015/9) ||
||POP ||1.2m x 2.4m x h 0.9645m ||PR2 chamber -Y ||1.204m from concrete floor ||reuse iKAGRA PSL table instead of buying a new one ||
||POS ||1.2m x 2.4m x h 1.018m ||SR2 chamber -X ||1.212m from concrete floor ||height to be confirmed ||
||AS ||1.2m x 2.4m x h 1.078m ||OMC chamber +X (table is put on mortar surface) ||1.272m ||height to be confirmed ||
Line 19: Line 23:
* Beam height written here is from the mortar surface.
* Beam height written here is from the mortar surface unless otherwise noted.
Line 23: Line 28:
* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m) * Difference between the beam height from the floor (concrete surface or mortar surface) and the height of the optical table should be larger than 7.6 inch (0.19m)

KAGRA Output Optical Tables

iKAGRA

name

size and height

closest chamber

beam height

optical layout drawing / status

IMC REFL

1m x 1m x h 0.940m (CL-1010TS)

MCF chamber

1.134m - 0.012m

JGW-D1503412 / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed

MCT

1m x 1m x h 0.955m

MCE chamber

1.149m - 0.027m

JGW-D1503412 / purchased(2014/10), installed

REFL

1m x 1m x h 0.947m (CL-1010TS)

IFI chamber

1.141m - 0.019m

to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2)

IMMT1T

300mm x 400mm + extension(250mm x 300mm) (breadboard on pylon)

MMT chamber

???

installed(klog #862)

bKAGRA

name

size and height

closest chamber

beam height

IMC REFL

1.2m x 2.4m x h 0.940m

MCF chamber -Y

1.134m - 0.012m

JGW-D1503412 / purchased(2014/10)

REFL

1.2m x 2.4m x h 0.947m

IFI chamber -Y

1.141m - 0.019m

used at Kashiwa for now, purchased(2015/9)

IMMT2

1m x 1m x h 0.947m (CL-1010TS)

IFI chamber +Y

1.141m - 0.019m

VIS is borrowing now, purchased(2014/10)

ETMX

1.2m x 2.0m x h 1.006m

EXT chamber +X (table is put on mortar surface)

1.200m

size confirmed(2016/7/11)

ETMY

1.2m x 2.0m x h 1.006m

EYT chamber +Y (table is put on mortar surface)

1.200m

size confirmed(2016/7/11)

POX

1m x 1m x h 1.043m (CL-1010TS)

SR3 chamber (no isolation cutting for tables)

1.257m

used for REFL in iKAGRA, purchased(2015/9)

POY

1m x 1m x h 0.936m (CL-1010TS)

PR3 chamber -Y

1.150m

used for IMC REFL in iKAGRA, purchased(2015/9)

POP

1.2m x 2.4m x h 0.9645m

PR2 chamber -Y

1.204m from concrete floor

reuse iKAGRA PSL table instead of buying a new one

POS

1.2m x 2.4m x h 1.018m

SR2 chamber -X

1.212m from concrete floor

height to be confirmed

AS

1.2m x 2.4m x h 1.078m

OMC chamber +X (table is put on mortar surface)

1.272m

height to be confirmed

* Beam height written here is from the mortar surface unless otherwise noted.

* Mortar thickness is about 20mm by design.

* Difference between the beam height from the floor (concrete surface or mortar surface) and the height of the optical table should be larger than 7.6 inch (0.19m)

* See JGW-D1402607

* iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson

KAGRA/Subgroups/IOO/OutputTables (last edited 2022-05-11 06:27:47 by ChenDan)