Differences between revisions 44 and 68 (spanning 24 versions)
Revision 44 as of 2016-06-06 18:11:53
Size: 2381
Comment:
Revision 68 as of 2022-05-11 06:27:47
Size: 3271
Editor: ChenDan
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:

 * [[KAGRA/Subgroups/IOO/OutputTables/Optics| Optics for Output Tables]]
Line 4: Line 7:
||IMC REFL|| 1m x 1m x h 0.940m (CL-1010TS) ||MCF chamber || 1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed||
||MCT || 1m x 1m x h 0.955m ||MCE chamber || 1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10), installed||
||REFL ||  1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber || 1.141m - 0.019m ||to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2) ||
||IMMT1T || 300mm x 400mm (breadboard on pylon) ||MMT chamber ||??? ||??? ||
||IMC REFL ||1m x 1m x h 0.940m (CL-1010TS) ||MCF chamber ||1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed ||
||MCT ||1m x 1m x h 0.955m ||MCE chamber ||1.149m - 0.027m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10), installed ||
||REFL ||1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber ||1.141m - 0.019m ||to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2) ||
||IMMT1T ||300mm x 400mm + extension(250mm x 300mm) (breadboard on pylon) ||MMT chamber ||??? ||installed([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=862|klog #862]]) ||
Line 11: Line 15:
||IMC REFL|| 1.2 x 2.4m x h 0.940m ||MCF chamber || 1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / purchased(2014/10)||
||REFL || 1.2 x 2.4m x h 0.947m ||IFI chamber || 1.141m - 0.019m ||used at Kashiwa for now, purchased(2015/9)||
||IMMT2 || 1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber || 1.141m - 0.019m ||VIS is borrowing now, purchased(2014/10)||
||ETMX || 1m x 1m x h 0.986m (CL-1010TS) ||EXT chamber || 1.200m || may use bigger table instead||
||ETMY || 1m x 1m x h 0.986m (CL-1010TS) ||EYT chamber || 1.200m || may use bigger table instead||
||POX || 1m x 1m x h 1.043m (CL-1010TS) || SR3 chamber || 1.257m ||used for REFL in iKAGRA, purchased(2015/9)||
||POY || 1m x 1m x h 0.936m (CL-1010TS) || PR3 chamber || 1.150m ||used for IMC REFL in iKAGRA, purchased(2015/9)||
||POP || 1.2 x 2.4m x h 0.970m || PR2 chamber || 1.184m || ||
||POS || 1.2 x 2.4m x h 1.000m || SR2 chamber || 1.217m || ||
||AS || 1.2 x 2.4m x h 1.000m || SRM chamber || 1.271m || ||
||IMC REFL ||1.2m x 2.4m x h 0.940m ||MCF chamber -Y ||1.134m - 0.012m ||[[http://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=3412|JGW-D1503412]] / used for IMC REFL (2016/11),purchased(2014/10) ||
||REFL ||1.2m x 2.4m x h 0.947m ||IFI chamber -Y ||1.141m - 0.019m ||installed(2017/2); was used at Kashiwa ; purchased(2015/9) ||
||IMMT2 ||1m x 1m x h 0.947m (CL-1010TS) ||IFI chamber +Y ||1.141m - 0.019m ||VIS is borrowing now, purchased(2014/10) ||
||ETMX ||1.2m x 2.0m x h 1.006m ||EXT chamber +X (table is put on mortar surface) ||1.200m ||brought to Xend(2017/2/23);size confirmed(2016/7/11) ||
||ETMY ||1.2m x 2.0m x h 1.006m ||EYT chamber +Y (table is put on mortar surface) ||1.200m ||brought to Yend(2017/2/24);size confirmed(2016/7/11) ||
||POX ||1m x 1m x h 1.043m (CL-1010TS) ||SR3 chamber -X (-X side is more spacious) ||1.257m ||will be used for AS for bKAGRAp1, used for REFL in iKAGRA, purchased(2015/9), used for mirror scattering experiment(2022/5/9) ||
||POY ||1m x 1m x h 0.936m (CL-1010TS) ||PR3 chamber +Y ||1.150m ||used for IMC REFL in iKAGRA->now used as workbench for IMMT work, purchased(2015/9) ; anchor holes are at -Y side, but anchors are not needed and it should be at +Y for VIS work(2017/4/14)||
||POP ||1.2m x 2.4m x h 0.9645m ||PR2 chamber -Y ||1.204m from concrete floor ||now at outside of MCF clean booth;reuse iKAGRA PSL table instead of buying a new one ||
||POS ||1.2m x 2.4m x h 1.018m ||SR2 chamber -X ||1.212m from concrete floor ||installed(2018/11/08);height confirmed(2016/11/14) ||
||AS ||1.2m x 2.4m x h 1.078m ||OMC chamber +X (table is put on mortar surface) ||1.272m ||installed(2017/3/23);height confirmed(2016/11/14) ||
Line 22: Line 26:
* Beam height written here is from the mortar surface.
* Beam height written here is from the mortar surface unless otherwise noted.
Line 26: Line 31:
* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m) * Difference between the beam height from the floor (concrete surface or mortar surface) and the height of the optical table should be larger than 7.6 inch (0.19m)

KAGRA Output Optical Tables

iKAGRA

name

size and height

closest chamber

beam height

optical layout drawing / status

IMC REFL

1m x 1m x h 0.940m (CL-1010TS)

MCF chamber

1.134m - 0.012m

JGW-D1503412 / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed

MCT

1m x 1m x h 0.955m

MCE chamber

1.149m - 0.027m

JGW-D1503412 / purchased(2014/10), installed

REFL

1m x 1m x h 0.947m (CL-1010TS)

IFI chamber

1.141m - 0.019m

to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2)

IMMT1T

300mm x 400mm + extension(250mm x 300mm) (breadboard on pylon)

MMT chamber

???

installed(klog #862)

bKAGRA

name

size and height

closest chamber

beam height

IMC REFL

1.2m x 2.4m x h 0.940m

MCF chamber -Y

1.134m - 0.012m

JGW-D1503412 / used for IMC REFL (2016/11),purchased(2014/10)

REFL

1.2m x 2.4m x h 0.947m

IFI chamber -Y

1.141m - 0.019m

installed(2017/2); was used at Kashiwa ; purchased(2015/9)

IMMT2

1m x 1m x h 0.947m (CL-1010TS)

IFI chamber +Y

1.141m - 0.019m

VIS is borrowing now, purchased(2014/10)

ETMX

1.2m x 2.0m x h 1.006m

EXT chamber +X (table is put on mortar surface)

1.200m

brought to Xend(2017/2/23);size confirmed(2016/7/11)

ETMY

1.2m x 2.0m x h 1.006m

EYT chamber +Y (table is put on mortar surface)

1.200m

brought to Yend(2017/2/24);size confirmed(2016/7/11)

POX

1m x 1m x h 1.043m (CL-1010TS)

SR3 chamber -X (-X side is more spacious)

1.257m

will be used for AS for bKAGRAp1, used for REFL in iKAGRA, purchased(2015/9), used for mirror scattering experiment(2022/5/9)

POY

1m x 1m x h 0.936m (CL-1010TS)

PR3 chamber +Y

1.150m

used for IMC REFL in iKAGRA->now used as workbench for IMMT work, purchased(2015/9) ; anchor holes are at -Y side, but anchors are not needed and it should be at +Y for VIS work(2017/4/14)

POP

1.2m x 2.4m x h 0.9645m

PR2 chamber -Y

1.204m from concrete floor

now at outside of MCF clean booth;reuse iKAGRA PSL table instead of buying a new one

POS

1.2m x 2.4m x h 1.018m

SR2 chamber -X

1.212m from concrete floor

installed(2018/11/08);height confirmed(2016/11/14)

AS

1.2m x 2.4m x h 1.078m

OMC chamber +X (table is put on mortar surface)

1.272m

installed(2017/3/23);height confirmed(2016/11/14)

* Beam height written here is from the mortar surface unless otherwise noted.

* Mortar thickness is about 20mm by design.

* Difference between the beam height from the floor (concrete surface or mortar surface) and the height of the optical table should be larger than 7.6 inch (0.19m)

* See JGW-D1402607

* iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson

KAGRA/Subgroups/IOO/OutputTables (last edited 2022-05-11 06:27:47 by ChenDan)