Line 28: Line 28:
* Difference between the beam height from the concrete surface and the height of the optical table should be larger than 7.6 inch (0.19m) * Difference between the beam height from the floor (concrete surface or mortar surface) and the height of the optical table should be larger than 7.6 inch (0.19m)

KAGRA Output Optical Tables

iKAGRA

name

size and height

closest chamber

beam height

optical layout drawing / status

IMC REFL

1m x 1m x h 0.940m (CL-1010TS)

MCF chamber

1.134m - 0.012m

JGW-D1503412 / to be used for POY (or POX) for bKAGRA, purchased(2015/9), installed

MCT

1m x 1m x h 0.955m

MCE chamber

1.149m - 0.027m

JGW-D1503412 / purchased(2014/10), installed

REFL

1m x 1m x h 0.947m (CL-1010TS)

IFI chamber

1.141m - 0.019m

to be used for POX (or POY) for bKAGRA, purchased(2015/9), returned from VIS (2016/2)

IMMT1T

300mm x 400mm + extension(250mm x 300mm) (breadboard on pylon)

MMT chamber

???

installed(klog #862)

bKAGRA

name

size and height

closest chamber

beam height

IMC REFL

1.2m x 2.4m x h 0.940m

MCF chamber -Y

1.134m - 0.012m

JGW-D1503412 / purchased(2014/10)

REFL

1.2m x 2.4m x h 0.947m

IFI chamber -Y

1.141m - 0.019m

used at Kashiwa for now, purchased(2015/9)

IMMT2

1m x 1m x h 0.947m (CL-1010TS)

IFI chamber +Y

1.141m - 0.019m

VIS is borrowing now, purchased(2014/10)

ETMX

1.2m x 2.0m x h 0.986m

EXT chamber +X (table is put on mortar surface)

1.200m

size confirmed(2016/7/11)

ETMY

1.2m x 2.0m x h 0.986m

EYT chamber +Y (table is put on mortar surface)

1.200m

size confirmed(2016/7/11)

POX

1m x 1m x h 1.043m (CL-1010TS)

SR3 chamber (no isolation cutting for tables)

1.257m

used for REFL in iKAGRA, purchased(2015/9)

POY

1m x 1m x h 0.936m (CL-1010TS)

PR3 chamber -Y

1.150m

used for IMC REFL in iKAGRA, purchased(2015/9)

POP

1.2m x 2.4m x h 0.9645m

PR2 chamber -Y

1.204m from concrete floor

reuse iKAGRA PSL table instead of buying a new one

POS

1.2m x 2.4m x h 1.000m

SR2 chamber -X

1.212m from concrete floor

height to be confirmed

AS

1.2m x 2.4m x h 1.000m

OMC chamber +X (table is put on mortar surface)

1.272m

height to be confirmed

* Beam height written here is from the mortar surface unless otherwise noted.

* Mortar thickness is about 20mm by design.

* Difference between the beam height from the floor (concrete surface or mortar surface) and the height of the optical table should be larger than 7.6 inch (0.19m)

* See JGW-D1402607

* iKAGRA AS table is omitted because we are not using AS port for iKAGRA 3km Michelson