Line 33: Line 33:
 * There is only QPD2 (K1:TMS-X_) on the TMSX in-air path. At a random Gouy phase position.  * There is only QPD2 (K1:TMS-X_IR_QPDA2_{PIT,YAW}) on the TMSX in-air path. At a random Gouy phase position.

Angular Sensing and Control (Oct, 2022)

WFS ports

REFL (17, 45 MHz)

POP (17, 45 MHz)

AS (17, 28 MHz)

DC QPD ports

TMSX

TMSY

POP Forward

  • There are two DC QPDs on POP Forward, used for the initial alignment

DC PDs

  • There are POP_P and POP_S DC PDs on POP.

WFS Commissioning

WFS DC centering

  • Open the REFL shutter for REFL WFS
  • Beam spots on the quadrant diodes must be centered (DC centering)
    • PZTs and picomotors are available

Single Y arm

Single X arm

PRMI

PRFPMI

DRFPMI

Next Steps

Infrastructure

  • Guardian implementation
    • DC centering loops on REFL, POP, and AS
    • Single Y, X arms, and PRMI guardstates for initial alignment
  • Add trigger for the main ASC switch (K1:ASC-WFS_GAIN) similarly to the IMC switch (K1:IMC-WFS_GAIN)

Simulation

  • Compare the measured sensing matrices against the simulation
    • Koyama-kun's simulation GUI tool is available on the workstations
      • sitemap > Commissioning Top > finesse GUI

Integration

  • Implement single-Y, single-X, and PRMI controls for the initial alignment
    • If the alignment is too off, first ADS then WFS control?
  • PRFPMI/DRFPMI angular controls
  • Noise budget

Known issues

  • TMSX PIT-YAW coupling
    • The beam is slightly not centered in yaw on the second lens on the in-air table. Adjusting the beam position on the lens might fix the problem.