Differences between revisions 1 and 15 (spanning 14 versions)
Revision 1 as of 2020-11-10 15:11:25
Size: 467
Comment:
Revision 15 as of 2020-11-11 17:22:01
Size: 2822
Comment:
Deletions are marked like this. Additions are marked like this.
Line 8: Line 8:
Kokeyama, Hirose, Wang, YamamotoH, Leonaridi, Koyama, Oshino, Akutus, Michimura, Yuzurihara, Somiya, Miyakawa, Oshino
Line 12: Line 13:
|| IFO model || Kokeyama || || 5 mins ||
|| OMC model || Prak, Kokeyama || || 5 mins ||
|| Finesse GUI || Koyama, Hirose || || 10 mins ||
|| Birefringence || Wang || || 5 mins ||
|| Finesse IFO model || Kokeyama || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12225|o]]|| 5 mins ||
|| OMC model || Park || || 5 mins ||
|| Finesse GUI || Koyama, Hirose || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12227|GUI]][[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12226|cross check]]|| 10 mins ||
|| Birefringence || Wang || [[ https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12222|link]] || 10 mins ||
Line 18: Line 19:
  == Minues ==

=== OMC ===
 * Wedge angles of OMC1, OMC2 matters?
 * Should we include the thickness (and wedge) of OMC1? (Somiya-san) Gouy phase difference between V and H is <1 deg, which should be negligible.
 * (Hiro-san)The slope (from HOM 0 -8 of the experiment) maybe reflecting the spatial abbreviation of the test masses having longer wavelength more than short wavelength
 * (Akutsu-san) Aso-san’s document: [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10527|this]]. The current OMC is base on the **-R500.*** files. It is nice to confirm it with him! In my memo, with this document, I did double-checking of the Aso-san’s ray-trace with another commercial simulator.

=== GUI ===
 * The windows installation procedure is ready
 * (Hiro-san) Can you add mirrors? - No
 * We can expand the configuration, such as OMC and IMC.
 * (Akutsu-san) Can you change macroscopic lengths? - Yes
 
=== Birefringence ===
 * Mach-Zhender model to simulate S->S, S->P, P->S, P->P conversion.
 * The intuitive understanding of this model is to convert S-P basis to e-o basis (extraordinary and ordinary axes) by the first BS, and covert back to S-P by the second BS.
 * Are the phi maps really correct
 * We need alpha_{-} map for the simulation
   * We look for measurement data with circular polarization (P.6 of Haoyou's slide)
   * Is phi and alpha_{-} related?
 * [[https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0110/G1911070/002/Polarization%20and%20Absorption%20Maps_f2f201912.pdf|This]] measurement shows only a few degree birefringence (sample sapphire, NAOJ measurement) whereas our phi map is -40~40 degrees.
 * [[https://journals.aps.org/prapplied/abstract/10.1103/PhysRevApplied.14.014021|Hirose-san paper]] (showing the measurement method)
 * Maybe we can have a small meeting with Matteo nad Aso-san for their help?

Simulation Summary (so-far) Meeting

2020 Nov 11, 3pm - 5pm, zoom2

Guest

Hiro Yamamoto Sensei

Participants

Kokeyama, Hirose, Wang, YamamotoH, Leonaridi, Koyama, Oshino, Akutus, Michimura, Yuzurihara, Somiya, Miyakawa, Oshino

Agenda

Topic

Speaker

Slide Link

Dur

Finesse IFO model

Kokeyama

o

5 mins

OMC model

Park

5 mins

Finesse GUI

Koyama, Hirose

GUIcross check

10 mins

Birefringence

Wang

link

10 mins

  • We will have free discussion time after each talk, which is not shown in the table

Minues

OMC

  • Wedge angles of OMC1, OMC2 matters?
  • Should we include the thickness (and wedge) of OMC1? (Somiya-san) Gouy phase difference between V and H is <1 deg, which should be negligible.

  • (Hiro-san)The slope (from HOM 0 -8 of the experiment) maybe reflecting the spatial abbreviation of the test masses having longer wavelength more than short wavelength
  • (Akutsu-san) Aso-san’s document: this. The current OMC is base on the **-R500.*** files. It is nice to confirm it with him! In my memo, with this document, I did double-checking of the Aso-san’s ray-trace with another commercial simulator.

GUI

  • The windows installation procedure is ready
  • (Hiro-san) Can you add mirrors? - No
  • We can expand the configuration, such as OMC and IMC.
  • (Akutsu-san) Can you change macroscopic lengths? - Yes

Birefringence

  • Mach-Zhender model to simulate S->S, S->P, P->S, P->P conversion.

  • The intuitive understanding of this model is to convert S-P basis to e-o basis (extraordinary and ordinary axes) by the first BS, and covert back to S-P by the second BS.
  • Are the phi maps really correct
  • We need alpha_{-} map for the simulation
    • We look for measurement data with circular polarization (P.6 of Haoyou's slide)
    • Is phi and alpha_{-} related?
  • This measurement shows only a few degree birefringence (sample sapphire, NAOJ measurement) whereas our phi map is -40~40 degrees.

  • Hirose-san paper (showing the measurement method)

  • Maybe we can have a small meeting with Matteo nad Aso-san for their help?

KAGRA/Subgroups/MIF/Simulation/SimMeeting20201111 (last edited 2020-11-11 17:22:01 by KeikoKokeyama)