<<TableOfContents(3)>>
Line 2: Line 4:

=== IOO1 ===
==== ADC1 ====
|| ADC port || Sensor || manager || memo ||
|| ch1-4 || Seismometer1 IMC || Miyo || ||
|| ch5-8 || Seismometer2 IMC || Miyo || ||
|| ch9-12 || From IMC rack || Yokozawa || Connect to BNC D-sub converter at IMC rack (ACC, ACC, empty, empty)||
|| ch13-16 || PSL PEM2 || Kokeyama/Yokozawa || ||
|| ch17-20 || PSL PEM3 || Kekeyama/Yokozawa || ||
|| ch21-24 || IMC PEM|| Yokozawa || MIC, MIC, MIC, MIC(2018/12/17) ||
|| ch25-28 || ISS?|| || ||
|| ch29-32 || ISS?|| || ||
 
=== IX0 ===
==== ADC0 ====
|| ADC port || Sensor || manager || memo ||
|| ch1-4 || Baffle PD(?)|| ?? || Not installed yet ||
|| ch5-8 || NAB Oplev|| ?? || ||
|| ch9-12 || IXC磁場測定用||Htanaka || ||
|| ch13-16 || PEM MAP作成用 || Yokozawa || ||
|| ch17-20 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter ||
|| ch21-24 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter ||
|| ch25-28 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter ||
|| ch29-32 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter ||

=== IY0 ===
==== ADC0 ====
|| ADC port || Sensor || manager || memo ||
|| ch1-4 || Baffle PD(?)|| ?? || Not installed yet ||
|| ch5-8 || NAB oplev|| ?? || ||
|| ch9-12 || PEM MAP作成用|| Yokozawa || ||
|| ch13-16 || from POP || Yokozawa || Connected to the BNC DSub converter||
|| ch17-20 || from POP|| Yokozawa || Connected to the BNC DSub converter||
|| ch21-24 || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9340|Air Envrionment Sensor No6]] || Miyo || klgo??? ||
|| ch25-28 || || || ||
|| ch29-32 || || || ||


=== IX1 ===
==== ADC0 ====
|| ADC port || Sensor || manager || memo ||
|| ch1-24 || VIS/CRY|| - || No PEM ports ||
|| ch25-28 || Seismometer || Miyo || ||

=== IX1 ===
==== ADC1 ====
|| ADC port || Sensor || manager || memo ||
|| ch1-24 || VIS/CRY|| - || No PEM ports ||
|| ch25-28 || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9339|Air Environment Monitor No5]] || Miyo || klog??? ||

=== EX0 rack ADC1(?) CLIO ADC ===
|| ADC port || Sensor || manager || memo ||
|| ch1-4 || TMS || ?? || Not installed yet ||
|| ch5-8 || TMS || ?? || For TMS QPD monitor ||
|| ch9-12 || TMS || ?? || For TMS QPD monitor ||
|| ch13-16 || TMS || ?? || ||
|| ch17-20 || PEM || Yokozawa || ||
|| ch21-24 || PEM || Yokozawa || ||
|| ch25-28 || PEM || Yokozawa || ||
|| ch29-32 || PEM || Yokozawa || ||

=== Xend2F EX1 rack ADC0 ===
|| ch25-28 || || || ||
 



=== center2 IX0 rack ADC0 ===

|| ADC port || Sensor || manager || memo ||
|| ch1-4 || Baffle PD(?)|| ?? || Not installed yet ||
|| ch5-8 || IYA NAB oplev(?)|| ?? || ?? ||
|| ch9-12 ||POP/BS(?) || || ||
|| ch13-16 ||POP/BS(?) || || ||
|| ch17-20 || || || ||
|| ch21-24 || || || ||
|| ch25-28 || || || ||
|| ch29-32 || || || ||

ADC and Racks for PEM

IOO1

ADC1

ADC port

Sensor

manager

memo

ch1-4

Seismometer1 IMC

Miyo

ch5-8

Seismometer2 IMC

Miyo

ch9-12

From IMC rack

Yokozawa

Connect to BNC D-sub converter at IMC rack (ACC, ACC, empty, empty)

ch13-16

PSL PEM2

Kokeyama/Yokozawa

ch17-20

PSL PEM3

Kekeyama/Yokozawa

ch21-24

IMC PEM

Yokozawa

MIC, MIC, MIC, MIC(2018/12/17)

ch25-28

ISS?

ch29-32

ISS?

IX0

ADC0

ADC port

Sensor

manager

memo

ch1-4

Baffle PD(?)

??

Not installed yet

ch5-8

NAB Oplev

??

ch9-12

IXC磁場測定用

Htanaka

ch13-16

PEM MAP作成用

Yokozawa

ch17-20

From SRM rack

Yokozawa

Connect to the BNC DSub converter

ch21-24

From SRM rack

Yokozawa

Connect to the BNC DSub converter

ch25-28

From SRM rack

Yokozawa

Connect to the BNC DSub converter

ch29-32

From SRM rack

Yokozawa

Connect to the BNC DSub converter

IY0

ADC0

ADC port

Sensor

manager

memo

ch1-4

Baffle PD(?)

??

Not installed yet

ch5-8

NAB oplev

??

ch9-12

PEM MAP作成用

Yokozawa

ch13-16

from POP

Yokozawa

Connected to the BNC DSub converter

ch17-20

from POP

Yokozawa

Connected to the BNC DSub converter

ch21-24

Air Envrionment Sensor No6

Miyo

klgo???

ch25-28

ch29-32

IX1

ADC0

ADC port

Sensor

manager

memo

ch1-24

VIS/CRY

-

No PEM ports

ch25-28

Seismometer

Miyo

IX1

ADC1

ADC port

Sensor

manager

memo

ch1-24

VIS/CRY

-

No PEM ports

ch25-28

Air Environment Monitor No5

Miyo

klog???

EX0 rack ADC1(?) CLIO ADC

ADC port

Sensor

manager

memo

ch1-4

TMS

??

Not installed yet

ch5-8

TMS

??

For TMS QPD monitor

ch9-12

TMS

??

For TMS QPD monitor

ch13-16

TMS

??

ch17-20

PEM

Yokozawa

ch21-24

PEM

Yokozawa

ch25-28

PEM

Yokozawa

ch29-32

PEM

Yokozawa

Xend2F EX1 rack ADC0

ch25-28

center2 IX0 rack ADC0

ADC port

Sensor

manager

memo

ch1-4

Baffle PD(?)

??

Not installed yet

ch5-8

IYA NAB oplev(?)

??

??

ch9-12

POP/BS(?)

ch13-16

POP/BS(?)

ch17-20

ch21-24

ch25-28

ch29-32