Size: 2387
Comment:
|
Size: 2951
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
<<TableOfContents(3)>> |
|
Line 3: | Line 5: |
* center1 IOO1 rack ADC1 |
=== IOO1 === ==== ADC1 ==== |
Line 8: | Line 10: |
|| ch9-12 || PSL PEM1 || Kokeyama/Yokozawa || || | || ch9-12 || From IMC rack || Yokozawa || Connect to BNC D-sub converter at IMC rack (ACC, ACC, empty, empty)|| |
Line 10: | Line 12: |
|| ch17-20 || PSL PEM3 || Kekeyama/Yokozawa || Will be moved to IMC PEM || || ch21-24 || IMC PEM|| Yokozawa || MIC, MIC, MIC(2018/09/15) || || ch25-28 || || || || || ch29-32 || || || || |
|| ch17-20 || PSL PEM3 || Kekeyama/Yokozawa || || || ch21-24 || IMC PEM|| Yokozawa || MIC, MIC, MIC, MIC(2018/12/17) || || ch25-28 || ISS?|| || || || ch29-32 || ISS?|| || || |
Line 15: | Line 17: |
* center2 IX0 rack ADC0 |
=== IX0 === ==== ADC0 ==== |
Line 19: | Line 21: |
|| ch5-8 || || || || || ch9-12 || || || || || ch13-16 || || || || || ch17-20 || || || || || ch21-24 || || || || || ch25-28 || || || || || ch29-32 || || || || |
|| ch5-8 || NAB Oplev|| ?? || || || ch9-12 || IXC磁場測定用||Htanaka || || || ch13-16 || PEM MAP作成用 || Yokozawa || || || ch17-20 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter || || ch21-24 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter || || ch25-28 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter || || ch29-32 || From SRM rack|| Yokozawa || Connect to the BNC DSub converter || |
Line 27: | Line 29: |
* center3 IY0 rack ADC0 | === IY0 === ==== ADC0 ==== |
Line 30: | Line 33: |
|| ch5-8 || || || || || ch9-12 || || || || || ch13-16 || || || || || ch17-20 || || || || |
|| ch5-8 || NAB oplev|| ?? || || || ch9-12 || PEM MAP作成用|| Yokozawa || || || ch13-16 || from POP || Yokozawa || Connected to the BNC DSub converter|| || ch17-20 || from POP|| Yokozawa || Connected to the BNC DSub converter|| |
Line 39: | Line 42: |
* center2F IX1 rack ADC0 | === IX1 === ==== ADC0 ==== |
Line 44: | Line 48: |
* center2F IX1 rack ADC1 | === IX1 === ==== ADC1 ==== |
Line 49: | Line 54: |
* Xend1F EX0 rack ADC1(?) CLIO ADC | === EX0 rack ADC1(?) CLIO ADC === |
Line 60: | Line 65: |
* Xend2F EX1 rack ADC0 | === Xend2F EX1 rack ADC0 === |
Line 66: | Line 71: |
* center2 IX0 rack ADC0 | === center2 IX0 rack ADC0 === |
Line 70: | Line 75: |
|| ch5-8 || || || || || ch9-12 || || || || || ch13-16 || || || || |
|| ch5-8 || IYA NAB oplev(?)|| ?? || ?? || || ch9-12 ||POP/BS(?) || || || || ch13-16 ||POP/BS(?) || || || |
Contents
ADC and Racks for PEM
IOO1
ADC1
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Seismometer1 IMC |
Miyo |
|
ch5-8 |
Seismometer2 IMC |
Miyo |
|
ch9-12 |
From IMC rack |
Yokozawa |
Connect to BNC D-sub converter at IMC rack (ACC, ACC, empty, empty) |
ch13-16 |
PSL PEM2 |
Kokeyama/Yokozawa |
|
ch17-20 |
PSL PEM3 |
Kekeyama/Yokozawa |
|
ch21-24 |
IMC PEM |
Yokozawa |
MIC, MIC, MIC, MIC(2018/12/17) |
ch25-28 |
ISS? |
|
|
ch29-32 |
ISS? |
|
|
IX0
ADC0
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Baffle PD(?) |
?? |
Not installed yet |
ch5-8 |
NAB Oplev |
?? |
|
ch9-12 |
IXC磁場測定用 |
Htanaka |
|
ch13-16 |
PEM MAP作成用 |
Yokozawa |
|
ch17-20 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
ch21-24 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
ch25-28 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
ch29-32 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
IY0
ADC0
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Baffle PD(?) |
?? |
Not installed yet |
ch5-8 |
NAB oplev |
?? |
|
ch9-12 |
PEM MAP作成用 |
Yokozawa |
|
ch13-16 |
from POP |
Yokozawa |
Connected to the BNC DSub converter |
ch17-20 |
from POP |
Yokozawa |
Connected to the BNC DSub converter |
ch21-24 |
Miyo |
klgo??? |
|
ch25-28 |
|
|
|
ch29-32 |
|
|
|
IX1
ADC0
ADC port |
Sensor |
manager |
memo |
ch1-24 |
VIS/CRY |
- |
No PEM ports |
ch25-28 |
Seismometer |
Miyo |
|
IX1
ADC1
ADC port |
Sensor |
manager |
memo |
ch1-24 |
VIS/CRY |
- |
No PEM ports |
ch25-28 |
Miyo |
klog??? |
EX0 rack ADC1(?) CLIO ADC
ADC port |
Sensor |
manager |
memo |
ch1-4 |
TMS |
?? |
Not installed yet |
ch5-8 |
TMS |
?? |
For TMS QPD monitor |
ch9-12 |
TMS |
?? |
For TMS QPD monitor |
ch13-16 |
TMS |
?? |
|
ch17-20 |
PEM |
Yokozawa |
|
ch21-24 |
PEM |
Yokozawa |
|
ch25-28 |
PEM |
Yokozawa |
|
ch29-32 |
PEM |
Yokozawa |
|
Xend2F EX1 rack ADC0
ch25-28 |
|
|
|
center2 IX0 rack ADC0
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Baffle PD(?) |
?? |
Not installed yet |
ch5-8 |
IYA NAB oplev(?) |
?? |
?? |
ch9-12 |
POP/BS(?) |
|
|
ch13-16 |
POP/BS(?) |
|
|
ch17-20 |
|
|
|
ch21-24 |
|
|
|
ch25-28 |
|
|
|
ch29-32 |
|
|
|