Size: 2953
Comment:
|
← Revision 34 as of 2018-12-20 17:32:40 ⇥
Size: 3025
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
<<TableOfContents(3)>> | <<TableOfContents(2)>> |
Line 3: | Line 3: |
== ADC and Racks for PEM == | = ADC and Racks for PEM = |
Line 5: | Line 5: |
=== IOO1 === ==== ADC1 ==== |
== IOO1 == === ADC1 === |
Line 17: | Line 17: |
=== IX0 === ==== ADC0 ==== |
== IX0 == === ADC0 === |
Line 29: | Line 29: |
=== IY0 === ==== ADC0 ==== |
== IY0 == === ADC0 === |
Line 42: | Line 42: |
=== IX1 === ==== ADC0 ==== || ADC port || Sensor || manager || memo || || ch1-24 || VIS/CRY|| - || No PEM ports || |
== IX1 == ||<#58D3F7> '''ADC Name''' ||<#58D3F7> '''Port''' ||<#58D3F7> '''Purpose''' ||<#58D3F7> '''Manager''' ||<#58D3F7> '''Memo''' || ||<|3> ADC0 || ch1-24 || VIS/CRY|| - || No PEM ports || |
Line 47: | Line 46: |
|| ch29-31 || Seismometer || Miyo || || ||<|4> ADC1 || ch1-24 || VIS/CRY|| - || No PEM ports || || ch25-28 || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9339|Air Environment Monitor No5]] || Miyo || klog??? || || ch29-31 || Test for VIS/CRY || - || || |
|
Line 48: | Line 51: |
=== IX1 === ==== ADC1 ==== || ADC port || Sensor || manager || memo || || ch1-24 || VIS/CRY|| - || No PEM ports || || ch25-28 || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9339|Air Environment Monitor No5]] || Miyo || klog??? || === EX0 === ==== ADC1(?) CLIO ADC ==== |
== EX0 == === ADC1(?) CLIO ADC === |
Line 66: | Line 63: |
=== EX1 === ==== ADC0 ==== |
== EX1 == === ADC0 === |
Line 73: | Line 70: |
=== IX0 === ==== ADC0 ==== |
== IX0 == === ADC0 === |
ADC and Racks for PEM
IOO1
ADC1
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Seismometer1 IMC |
Miyo |
|
ch5-8 |
Seismometer2 IMC |
Miyo |
|
ch9-12 |
From IMC rack |
Yokozawa |
Connect to BNC D-sub converter at IMC rack (ACC, ACC, empty, empty) |
ch13-16 |
PSL PEM2 |
Kokeyama/Yokozawa |
|
ch17-20 |
PSL PEM3 |
Kekeyama/Yokozawa |
|
ch21-24 |
IMC PEM |
Yokozawa |
MIC, MIC, MIC, MIC(2018/12/17) |
ch25-28 |
ISS? |
|
|
ch29-32 |
ISS? |
|
|
IX0
ADC0
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Baffle PD(?) |
?? |
Not installed yet |
ch5-8 |
NAB Oplev |
?? |
|
ch9-12 |
IXC磁場測定用 |
Htanaka |
|
ch13-16 |
PEM MAP作成用 |
Yokozawa |
|
ch17-20 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
ch21-24 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
ch25-28 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
ch29-32 |
From SRM rack |
Yokozawa |
Connect to the BNC DSub converter |
IY0
ADC0
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Baffle PD(?) |
?? |
Not installed yet |
ch5-8 |
NAB oplev |
?? |
|
ch9-12 |
PEM MAP作成用 |
Yokozawa |
|
ch13-16 |
from POP |
Yokozawa |
Connected to the BNC DSub converter |
ch17-20 |
from POP |
Yokozawa |
Connected to the BNC DSub converter |
ch21-24 |
Miyo |
klgo??? |
|
ch25-28 |
|
|
|
ch29-32 |
|
|
|
IX1
ADC Name |
Port |
Purpose |
Manager |
Memo |
ADC0 |
ch1-24 |
VIS/CRY |
- |
No PEM ports |
ch25-28 |
Seismometer |
Miyo |
|
|
ch29-31 |
Seismometer |
Miyo |
|
|
ADC1 |
ch1-24 |
VIS/CRY |
- |
No PEM ports |
ch25-28 |
Miyo |
klog??? |
||
ch29-31 |
Test for VIS/CRY |
- |
|
EX0
ADC1(?) CLIO ADC
ADC port |
Sensor |
manager |
memo |
ch1-4 |
TMS |
?? |
Not installed yet |
ch5-8 |
TMS |
?? |
For TMS QPD monitor |
ch9-12 |
TMS |
?? |
For TMS QPD monitor |
ch13-16 |
TMS |
?? |
|
ch17-20 |
PEM |
Yokozawa |
|
ch21-24 |
PEM |
Yokozawa |
|
ch25-28 |
PEM |
Yokozawa |
|
ch29-32 |
PEM |
Yokozawa |
|
EX1
ADC0
ch25-28 |
|
|
|
IX0
ADC0
ADC port |
Sensor |
manager |
memo |
ch1-4 |
Baffle PD(?) |
?? |
Not installed yet |
ch5-8 |
IYA NAB oplev(?) |
?? |
?? |
ch9-12 |
POP/BS(?) |
|
|
ch13-16 |
POP/BS(?) |
|
|
ch17-20 |
|
|
|
ch21-24 |
|
|
|
ch25-28 |
|
|
|
ch29-32 |
|
|
|