Size: 1244
Comment:
|
← Revision 10 as of 2018-12-27 10:01:30 ⇥
Size: 1167
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 26: | Line 26: |
* SENSOR(or SIGNAL; すぐに決めてどちらかにする) | * SENSOR(に統一することとする) |
Line 29: | Line 29: |
* place1 | * place1[[attachment:PEM_channel_name_place1.pdf|place1の目安]] |
Line 43: | Line 43: |
* IX0 * IY0 * IXC * IYC * EXC * EYC |
* IX * IY * EX * EY |
Line 57: | Line 55: |
* (A chamberを加えるかどうかは議論が必要だが、今の所置く余裕がない) | * XARM * YARM |
Line 65: | Line 64: |
* 1/2/3/... |
Definition of Channel name
motivation
- Define the rule of PEM channel name
- At 2018/12/26, there are many rules in the PEM channel
- ondotori style
- Seismometer style(VIS style)
- Yokozawa style
- Goal
- Define and write the rule of PEM channel name here.
- Change all PEM channel name as the rule.
Rule of PEM channel name
'K1:PEM-(sensor)_(place1)_(place2)_(DOF)'
- sensor
- TEMPERATURE
- HUMIDITY
- ACC
- MIC
- MAG
- SEIS
- WEATHER
- SENSOR(に統一することとする)
- 現状(2018/12/26)は以上だが、今後PEMが足されるにつれて追加する。
place1place1の目安
- RACK
- FIELD
- BOOTH
- MOZUMI
- PSL
- IMC
- IFI
- PR
- BS
- SR
- OMC
- POP
- POS
- IX
- IY
- EX
- EY
- IXV
- IYV
- EXV
- EYV
- TMSX
- TMSY
- PCALX
- PCALY
- XARM
- YARM
- place2
- No specific list
- GND, TABLE, PERI(PERISCOPE), CHAMBER, BEAMDUCT, ONTABLE(MIC), etc
- DOF
- X/Y/Z
- 18V/24V
- TEMP/HUMI/PRES
- etc...