Differences between revisions 36 and 47 (spanning 11 versions)
Revision 36 as of 2018-08-23 14:00:52
Size: 3431
Comment:
Revision 47 as of 2018-11-20 07:31:18
Size: 4753
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
== KAGRA PEM Channels == = KAGRA PEM Channels =
Line 3: Line 3:
== Ondotori ==
 * [[KAGRA/Subgroups/DGS/Projects/Rem|Ondotori System]]
Line 4: Line 6:
 * PSL == PSL ==
Line 8: Line 10:
|| accelerometer || TEAC 710 || K1:PEM-PSL_ACC_TABLE3_Z || [[attachment:PEM_pic_ACC_TEAC_table3.pdf|pic]] || m/s^2 || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8522|ACC]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8525|Amp]] || || accelerometer || TEAC 710 || K1:PEM-PSL_ACC_TABLE3_Z || [[attachment:PEM_pic_ACC_TEAÇ_table3.pdf|pic]] || m/s^2 || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8522|ACC]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8525|Amp]] ||
Line 11: Line 13:
|| magnetometer || MAG13 MCL100 || K1:PEM-PSL_MAG_LASERRACK_(X|Y|Z) || pic || T || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7535|MAG13]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8181|WF]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8519|Distrobutor]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8518|Power]]||
|| microphone || (B&K) 4188-A-021 || K1:PEM-PSL_MIC_CENTER || pic || Pa || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8142|MIC]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8142|amp]]||
|| magnetometer || MAG13 MCL100 || K1:PEM-PSL_MAG_LASERRACK_(X|Y|Z) || [[attachment:PEM_pic_MAG_pslrack.pdf|pic]] || T || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7535|MAG13]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8181|WF]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8519|Distrobutor]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8518|Power]]||
|| microphone || (B&K) 4188-A-021 || K1:PEM-PSL_MIC_CENTER || [[attachment:PEM_pic_MIC_center.pdf|pic]] || Pa || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8142|MIC]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8142|amp]]||

== IMC ==
|| PEM || Sensor || Channel name (_OUT_DQ) || Picture || Calibration(unit) || Memo(S number) ||
|| microphone || (B&K) 4188-A-021 || K1:PEM-IMC_MIC_REFL1 || [[|pic]] || Pa || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8974|MIC]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8975|amp]]||
|| microphone || (B&K) 4188-A-021 || K1:PEM-IMC_MIC_REFL2 || [[|pic]] || Pa || [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8976|MIC]], [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=8975|amp]]||
Line 15: Line 22:
 * [[KAGRA/Subgroups/DGS/Projects/Rem|Ondotori System]] == Seismometer ==
||<#F0F0FF> Snumber || Place || Sensor || Channel name (_OUT_DQ) || picture || calibration(unit) || Memo ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7552|JGW-S1707552]] || IXV || Trillium 12QA || K1:PEM-IXV_SEIS_(NS/WE/Z)_SENSINF || pic || m/s || memo ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] EXV || Trillium 120QA || K1:PEM-EXV_SEIS_(NS/WE/Z)_SENSINF || pic || m/s || memo ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || EYV || Trillium 120QA|| K1:PEM-EYV_SEIS_(NS/WE/Z)_SENSINF || pic || m/s || Now placed in IXV for noisemeasurement ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || MCe || Trillium compact 120-SV1 || K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_SENSINF || pic || m/s || memo ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || MCi || Trillium compact 120-SV1|| K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_SENSINF || pic || m/s || memo ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7528|JGW-S1707528]] || Fukuoka Univ. || Trillium compact 120-SV1|| ??? || pic || memo ||
Line 17: Line 31:
 * Seismometer
|| Place || Sensor || Channel name (_OUT_DQ) || picture || calibration(unit) || Memo ||
|| X front 2F|| Trillium 12QA || K1:PEM-IXV_SEIS_(NS/WE/Z)_SENSINF || pic || m/s^2(?) || memo ||
|| X end 2F || Trillium 120QA || K1:PEM-EXV_SEIS_(NS/WE/Z)_SENSINF || pic || m/s^2(?) || memo ||
|| Y end 2F || Trillium 120QA || K1:PEM-EYV_SEIS_(NS/WE/Z)_SENSINF || pic || m/s^2(?) || memo ||
|| IMC MCe || Trillium compact 120-SV1 || K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_SENSINF || pic || m/s^2(?) || memo ||
|| IMC MCi || Trillium compact 120-SV1 || K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_SENSINF || pic || m/s^2(?) || memo ||
|| Fukuoka Univ. || Trillium compact 120-SV1 || ??? || pic || memo ||

 * Temporary channels in IX0
== Temporary channels in IX0 ==
Line 30: Line 35:
 * Temporary channels in IY0 == Temporary channels in IY0 ==

KAGRA PEM Channels

Ondotori

PSL

PEM

Sensor

Channel name (_OUT_DQ)

Picture

Calibration(unit)

Memo(S number)

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE1_Z

pic

m/s^2

ACC, Amp

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE2_Z

pic

m/s^2

ACC, Amp

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE3_Z

pic

m/s^2

ACC, Amp

accelerometer

KISTLER 8640A5

K1:PEM-PSL_ACC_PERI_EXIT

pic

m/s^2

ACC, Amp

accelerometer

KISTLER 8640A5

K1:PEM-PSL_ACC_PERI_REFCAV

pic

m/s^2

ACC, Amp

magnetometer

MAG13 MCL100

K1:PEM-PSL_MAG_LASERRACK_(X|Y|Z)

pic

T

MAG13, WF, Distrobutor, Power

microphone

(B&K) 4188-A-021

K1:PEM-PSL_MIC_CENTER

pic

Pa

MIC, amp

IMC

PEM

Sensor

Channel name (_OUT_DQ)

Picture

Calibration(unit)

Memo(S number)

microphone

(B&K) 4188-A-021

K1:PEM-IMC_MIC_REFL1

[[|pic]]

Pa

MIC, amp

microphone

(B&K) 4188-A-021

K1:PEM-IMC_MIC_REFL2

[[|pic]]

Pa

MIC, amp

Seismometer

Snumber

Place

Sensor

Channel name (_OUT_DQ)

picture

calibration(unit)

Memo

JGW-S1707552

IXV

Trillium 12QA

K1:PEM-IXV_SEIS_(NS/WE/Z)_SENSINF

pic

m/s

memo

JGW-S170xxxx EXV

Trillium 120QA

K1:PEM-EXV_SEIS_(NS/WE/Z)_SENSINF

pic

m/s

memo

JGW-S170xxxx

EYV

Trillium 120QA

K1:PEM-EYV_SEIS_(NS/WE/Z)_SENSINF

pic

m/s

Now placed in IXV for noisemeasurement

JGW-S170xxxx

MCe

Trillium compact 120-SV1

K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_SENSINF

pic

m/s

memo

JGW-S170xxxx

MCi

Trillium compact 120-SV1

K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_SENSINF

pic

m/s

memo

JGW-S1707528

Fukuoka Univ.

Trillium compact 120-SV1

???

pic

memo

Temporary channels in IX0

Place

Sensor

Channel name

picture

Memo

IX0

Temporary

K1:PEM-IX0_SENSOR(1-12)

pic

Will be removed

Temporary channels in IY0

Place

Sensor

Channel name

picture

Memo

IY0

Temporary

K1:PEM-IY0_SENSOR(1-12)

pic

Will be removed