||<#F0F0FF> Snumber ||<#F0F0FF>Installed Place ||<#F0F0FF> Name ||<#F0F0FF> Channel name (SENSINF_OUT_DQ) ||<#F0F0FF> Unit ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7552|JGW-S1707552]] || IXV || Trillium 12QA || K1:PEM-IXV_SEIS_(NS/WE/Z)_ || m/s ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] ||  EXV || Trillium 120QA || K1:PEM-EXV_SEIS_(NS/WE/Z)_ || m/s ||
||--([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]])-- || --(EYV)-- || --(Trillium 120QA)-- || --(K1:PEM-EYV_SEIS_(NS/WE/Z)_)-- || --(m/s)-- ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || IXV || Trillium 120QA|| K1:PEM-IXV_SEIS_TEST_(NS/WE/Z)_ || m/s ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || MCe || Trillium compact 120-SV1 || K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_ || m/s ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || MCi || Trillium compact 120-SV1|| K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_ || m/s ||
||<#F0F0FF> Snumber ||<#F0F0FF>Installed Place (ADC port) ||<#F0F0FF> Name ||<#F0F0FF> Channel name (SENSINF_OUT_DQ) ||<#F0F0FF> Unit ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7552|JGW-S1707552]] || EXV (IX1, ADC0, 24-26) || Trillium 12QA || K1:PEM-IXV_SEIS_(NS/WE/Z)_ || m/s ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7551|JGW-S1707551]] || EXV (EX1, ADC0, 24-26) || Trillium 120QA || K1:PEM-EXV_SEIS_(NS/WE/Z)_ || m/s ||
||--([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7553|JGW-S1707553]])-- || --(EYV (EY1, ADC0, 24-26) )-- || --(Trillium 120QA)-- || --(K1:PEM-EYV_SEIS_(NS/WE/Z)_)-- || --(m/s)-- ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=7553|JGW-S1707553]] || IXV (IX1, ADC0, 28-30) || Trillium 120QA|| K1:PEM-IXV_SEIS_TEST_(NS/WE/Z)_ || m/s ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || MCe (IOO1, ADC1, 4-6) || Trillium compact 120-SV1 || K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_ || m/s ||
|| [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] || MCi (IOO1, ADC1, 0-2) || Trillium compact 120-SV1|| K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_ || m/s ||
Line 34: Line 34:
== Air Environment Sensors ==
||<#F0F0FF> Snumber ||<#F0F0FF>Using Rack ||<#F0F0FF> Name ||<#F0F0FF> Channel name (xxx_DQ) ||<#F0F0FF> Unit ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] ||IXV (IX1, ADC1, 24-27) ||[[KAGRA/Subgroups/GIF/EM/AirEnvironmentSensors|AirEnvironmentSensors]]|| K1-aaa_bbb_TEMPERATURE_ <<BR>>K1-aaa_bbb_HUMIDITY_<<BR>>K1-aaa_bbb_AIRPRESSURE_|| Degree<<BR>>%<<BR>>Pa ||
||[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxxx|JGW-S170xxxx]] ||EXV (EX1, ADC1, 24-27) ||[[KAGRA/Subgroups/GIF/EM/AirEnvironmentSensors|AirEnvironmentSensors]]|| K1-aaa_bbb_TEMPERATURE_ <<BR>>K1-aaa_bbb_HUMIDITY_<<BR>>K1-aaa_bbb_AIRPRESSURE_|| Degree<<BR>>%<<BR>>Pa ||

/!\ Now All Air monitor channels are assigned as <Place>_SEINSOR{1-4}_INMON.

KAGRA PEM Channel List

Ondotori

PSL

PEM

Sensor

Channel name (_OUT_DQ)

Picture

Calibration(unit)

Memo(S number)

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE1_Z

pic

m/s^2

ACC, Amp

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE2_Z

pic

m/s^2

ACC, Amp

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE3_Z

pic

m/s^2

ACC, Amp

accelerometer

KISTLER 8640A5

K1:PEM-PSL_ACC_PERI_EXIT

pic

m/s^2

ACC, Amp

accelerometer

KISTLER 8640A5

K1:PEM-PSL_ACC_PERI_REFCAV

pic

m/s^2

ACC, Amp

magnetometer

MAG13 MCL100

K1:PEM-PSL_MAG_LASERRACK_(X|Y|Z)

pic

T

MAG13, WF, Distrobutor, Power

microphone

(B&K) 4188-A-021

K1:PEM-PSL_MIC_CENTER

pic

Pa

MIC, amp

IMC

PEM

Sensor

Channel name (_OUT_DQ)

Picture

Calibration(unit)

Memo(S number)

microphone

(B&K) 4188-A-021

K1:PEM-IMC_MIC_REFL1

[[|pic]]

Pa

MIC, amp

microphone

(B&K) 4188-A-021

K1:PEM-IMC_MIC_REFL2

[[|pic]]

Pa

MIC, amp

Seismometer

Snumber

Installed Place (ADC port)

Name

Channel name (SENSINF_OUT_DQ)

Unit

JGW-S1707552

EXV (IX1, ADC0, 24-26)

Trillium 12QA

K1:PEM-IXV_SEIS_(NS/WE/Z)_

m/s

JGW-S1707551

EXV (EX1, ADC0, 24-26)

Trillium 120QA

K1:PEM-EXV_SEIS_(NS/WE/Z)_

m/s

JGW-S1707553

EYV (EY1, ADC0, 24-26)

Trillium 120QA

K1:PEM-EYV_SEIS_(NS/WE/Z)_

m/s

JGW-S1707553

IXV (IX1, ADC0, 28-30)

Trillium 120QA

K1:PEM-IXV_SEIS_TEST_(NS/WE/Z)_

m/s

JGW-S170xxxx

MCe (IOO1, ADC1, 4-6)

Trillium compact 120-SV1

K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_

m/s

JGW-S170xxxx

MCi (IOO1, ADC1, 0-2)

Trillium compact 120-SV1

K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_

m/s

JGW-S1707528

Fukuoka Univ.

Trillium compact 120-SV1

???

{*} Selfnoiseのグラフを載せる

Air Environment Sensors

Snumber

Using Rack

Name

Channel name (xxx_DQ)

Unit

JGW-S170xxxx

IXV (IX1, ADC1, 24-27)

AirEnvironmentSensors

K1-aaa_bbb_TEMPERATURE_
K1-aaa_bbb_HUMIDITY_
K1-aaa_bbb_AIRPRESSURE_

Degree
%
Pa

JGW-S170xxxx

EXV (EX1, ADC1, 24-27)

AirEnvironmentSensors

K1-aaa_bbb_TEMPERATURE_
K1-aaa_bbb_HUMIDITY_
K1-aaa_bbb_AIRPRESSURE_

Degree
%
Pa

/!\ Now All Air monitor channels are assigned as <Place>_SEINSOR{1-4}_INMON.

Temporary channels in IX0

Place

Sensor

Channel name

picture

Memo

IX0

Temporary

K1:PEM-IX0_SENSOR(1-12)

pic

Will be removed

Temporary channels in IY0

Place

Sensor

Channel name

picture

Memo

IY0

Temporary

K1:PEM-IY0_SENSOR(1-12)

pic

Will be removed