KAGRA PEM Channel List

Ondotori

PSL

PEM

Sensor

Channel name (_OUT_DQ)

Picture

Calibration(unit)

Memo(S number)

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE1_Z

pic

m/s^2

ACC, Amp

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE2_Z

pic

m/s^2

ACC, Amp

accelerometer

TEAC 710

K1:PEM-PSL_ACC_TABLE3_Z

pic

m/s^2

ACC, Amp

accelerometer

KISTLER 8640A5

K1:PEM-PSL_ACC_PERI_EXIT

pic

m/s^2

ACC, Amp

accelerometer

KISTLER 8640A5

K1:PEM-PSL_ACC_PERI_REFCAV

pic

m/s^2

ACC, Amp

magnetometer

MAG13 MCL100

K1:PEM-PSL_MAG_LASERRACK_(X|Y|Z)

pic

T

MAG13, WF, Distributor, Power

microphone

(B&K) 4188-A-021

K1:PEM-PSL_MIC_CENTER

pic

Pa

MIC, amp

IMC

PEM

Sensor

Channel name (_OUT_DQ)

Picture

Calibration(unit)

Memo(S number)

microphone

(B&K) 4188-A-021

K1:PEM-IMC_MIC_REFL1

[[|pic]]

Pa

MIC, amp

microphone

(B&K) 4188-A-021

K1:PEM-IMC_MIC_REFL2

[[|pic]]

Pa

MIC, amp

Seismometer

Snumber

Installed Place (ADC port)

Name

Channel name (SENSINF_OUT_DQ)

Unit

JGW-S1707552

EXV (IX1, ADC0, 24-26)

Trillium 12QA

K1:PEM-IXV_SEIS_(NS/WE/Z)_

m/s

JGW-S1707551

EXV (EX1, ADC0, 24-26)

Trillium 120QA

K1:PEM-EXV_SEIS_(NS/WE/Z)_

m/s

JGW-S1707553

EYV (EY1, ADC0, 24-26)

Trillium 120QA

K1:PEM-EYV_SEIS_(NS/WE/Z)_

m/s

JGW-S1707553

IXV (IX1, ADC0, 28-30)

Trillium 120QA

K1:PEM-IXV_SEIS_TEST_(NS/WE/Z)_

m/s

JGW-S170xxxx

MCe (IOO1, ADC1, 4-6)

Trillium compact 120-SV1

K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_

m/s

JGW-S170xxxx

MCi (IOO1, ADC1, 0-2)

Trillium compact 120-SV1

K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_

m/s

JGW-S1707528

Fukuoka Univ.

Trillium compact 120-SV1

???

{*} Selfnoiseのグラフを載せる

チャンネル変更案
K1:PEM-EXV_GND_TR120Q_X_BLRMS_10_30.rms (1mintrend)
K1:PEM-EXV_GND_TR120Q_X_BLRMS_1_3.rms
K1:PEM-EXV_GND_TR120Q_X_BLRMS_300M_1.rms
K1:PEM-EXV_GND_TR120Q_X_BLRMS_100M_300M.rms
K1:PEM-EXV_GND_TR120Q_X_BLRMS_30M_100M.rms
K1:PEM-EXV_GND_TR120Q_X_DQ (512Hz)
<コメント>
 * NS,WEはやめたほうがいい。わかりにくいので、X、Yにする。
 * SEISだけだと分かりにくい。地震計ごとにキャリブレーションも違うので地震計名を明記すべき。
 * GNDはなくてもいい。ただし、地震計が「どこ」に置かれているか明らかにしたほうがわかりやすい。

Air Environment Sensors

Snumber

Installed Place (ADC port)

Name

Channel name (xxx_OUTMON)

Unit

JGW-S1709339

IXV (IX1, ADC1, 24-27)

No.5

K1-IXV_WEATHER_{TEMP,HUMD,PRES}_

Degree, %, Pa

JGW-S1709339

IXV (IX1, ADC1, 24-27)

JGW-S170xxxx

EXV (EX1, ADC1, 24-27)

---

K1-EXV_WEATHER_{TEMP,HUMD,PRES}_

Degree, %, Pa

JGW-S170xxxx

EYV (EY1, ADC1, 24-27)

---

K1-EYV_WEATHER_{TEMP,HUMD,PRES}_

Degree, %, Pa

JGW-S170xxxx

IXC (IX0, ADC0, 16-27?)

JGW-S1709340

IYC (IY0, ADC0, 16-27?)

No6

K1-IYC_WEATHER_{TEMP,HUMD,PRES}_

Degree, %, Pa

Temporary channels in IX0

Place

Sensor

Channel name

picture

Memo

IX0

Temporary

K1:PEM-IX0_SENSOR(1-12)

pic

Will be removed

Temporary channels in IY0

Place

Sensor

Channel name

picture

Memo

IY0

Temporary

K1:PEM-IY0_SENSOR(1-12)

pic

Will be removed