Contents
KAGRA PEM Channel List
Ondotori
PSL
PEM |
Sensor |
Channel name (_OUT_DQ) |
Picture |
Calibration(unit) |
Memo(S number) |
accelerometer |
TEAC 710 |
K1:PEM-PSL_ACC_TABLE1_Z |
m/s^2 |
||
accelerometer |
TEAC 710 |
K1:PEM-PSL_ACC_TABLE2_Z |
m/s^2 |
||
accelerometer |
TEAC 710 |
K1:PEM-PSL_ACC_TABLE3_Z |
m/s^2 |
||
accelerometer |
KISTLER 8640A5 |
K1:PEM-PSL_ACC_PERI_EXIT |
m/s^2 |
||
accelerometer |
KISTLER 8640A5 |
K1:PEM-PSL_ACC_PERI_REFCAV |
m/s^2 |
||
magnetometer |
MAG13 MCL100 |
K1:PEM-PSL_MAG_LASERRACK_(X|Y|Z) |
T |
MAG13, WF, Distributor, Power |
|
microphone |
(B&K) 4188-A-021 |
K1:PEM-PSL_MIC_CENTER |
Pa |
IMC
PEM |
Sensor |
Channel name (_OUT_DQ) |
Picture |
Calibration(unit) |
Memo(S number) |
microphone |
(B&K) 4188-A-021 |
K1:PEM-IMC_MIC_REFL1 |
[[|pic]] |
Pa |
|
microphone |
(B&K) 4188-A-021 |
K1:PEM-IMC_MIC_REFL2 |
[[|pic]] |
Pa |
Seismometer
Snumber |
Installed Place (ADC port) |
Name |
Channel name (SENSINF_OUT_DQ) |
Unit |
EXV (IX1, ADC0, 24-26) |
Trillium 12QA |
K1:PEM-IXV_SEIS_(NS/WE/Z)_ |
m/s |
|
EXV (EX1, ADC0, 24-26) |
Trillium 120QA |
K1:PEM-EXV_SEIS_(NS/WE/Z)_ |
m/s |
|
EYV (EY1, ADC0, 24-26) |
Trillium 120QA |
K1:PEM-EYV_SEIS_(NS/WE/Z)_ |
m/s |
|
IXV (IX1, ADC0, 28-30) |
Trillium 120QA |
K1:PEM-IXV_SEIS_TEST_(NS/WE/Z)_ |
m/s |
|
MCe (IOO1, ADC1, 4-6) |
Trillium compact 120-SV1 |
K1:PEM-IMC_SEIS_MCE_(NS/WE/Z)_ |
m/s |
|
MCi (IOO1, ADC1, 0-2) |
Trillium compact 120-SV1 |
K1:PEM-IMC_SEIS_MCI_(NS/WE/Z)_ |
m/s |
|
Fukuoka Univ. |
Trillium compact 120-SV1 |
??? |
Selfnoiseのグラフを載せる
チャンネル変更案 K1:PEM-EXV_GND_TR120Q_X_BLRMS_10_30.rms (1mintrend) K1:PEM-EXV_GND_TR120Q_X_BLRMS_1_3.rms K1:PEM-EXV_GND_TR120Q_X_BLRMS_300M_1.rms K1:PEM-EXV_GND_TR120Q_X_BLRMS_100M_300M.rms K1:PEM-EXV_GND_TR120Q_X_BLRMS_30M_100M.rms K1:PEM-EXV_GND_TR120Q_X_DQ (512Hz) <コメント> * NS,WEはやめたほうがいい。わかりにくいので、X、Yにする。 * SEISだけだと分かりにくい。地震計ごとにキャリブレーションも違うので地震計名を明記すべき。 * GNDはなくてもいい。ただし、地震計が「どこ」に置かれているか明らかにしたほうがわかりやすい。
Air Environment Sensors
Snumber |
Installed Place (ADC port) |
Name |
Channel name (xxx_OUT_DQ) |
Unit |
Sample rate [Hz] |
IXV (IX1, ADC1, 24-27) |
No.5 |
K1-IXV_WEATHER_{TEMP,HUMD,PRES}_ |
Degree, %, Pa |
128 |
|
IYV (IY1, ADC1, 24-27) |
|
|
|
128 |
|
EXV (EX1, ADC1, 24-27) |
--- |
K1-EXV_WEATHER_{TEMP,HUMD,PRES}_ |
Degree, %, Pa |
128 |
|
EYV (EY1, ADC1, 24-27) |
--- |
K1-EYV_WEATHER_{TEMP,HUMD,PRES}_ |
Degree, %, Pa |
128 |
|
IXC (IX0, ADC0, 16-27?) |
|
|
|
128 |
|
IYC (IY0, ADC0, 20-23) |
No6 |
K1-IYC_WEATHER_{TEMP,HUMD,PRES}_ |
Degree, %, Pa |
128 |
Acording to JGW-T1809269, calibration from output voltage to each unit is given with
temp = ( Vout/78/0.001-100)/0.388 [deg_c] humd = Vout/10*100 [%] pressure = Vout/10*300 + 800 [hPa]
Then, "_GAIN" and "_OFFSET" parameters in cds filter of each channels are calculated by above equation with count value not voltage,
Name |
Value |
Unit |
_TEMP_OFFSET |
1.278e4 |
count |
_TEMP_GAIN |
2.017e-2 |
deg_c/count |
_HUMD_OFFSET |
0.0 |
count |
_HUMD_GAIN |
6.104e-3 |
%/count |
_PRES_OFFSET |
4.369e4 |
count |
_PRES_GAIN |
1.831e-2 |
hPa/count |
Temporary channels in IX0
Place |
Sensor |
Channel name |
picture |
Memo |
IX0 |
Temporary |
K1:PEM-IX0_SENSOR(1-12) |
pic |
Will be removed |
Temporary channels in IY0
Place |
Sensor |
Channel name |
picture |
Memo |
IY0 |
Temporary |
K1:PEM-IY0_SENSOR(1-12) |
pic |
Will be removed |