Contents
KAGRA PEM Channel List
Ondotori
PSL(-2018/12/10-)
| PEM | Sensor | Channel name (_OUT_DQ) | sampling rate[Hz] | Picture | Calibration(unit) | Memo(S number) | 
| accelerometer | TEAC 710 | K1:PEM-PSL_ACC_TABLE1_Z | 2048 | m/s^2 | ||
| accelerometer | TEAC 710 | K1:PEM-PSL_ACC_TABLE2_Z | 2048 | m/s^2 | ||
| accelerometer | TEAC 710 | K1:PEM-PSL_ACC_TABLE3_Z | 2048 | m/s^2 | ||
| accelerometer | KISTLER 8640A5 | K1:PEM-PSL_ACC_PERI_EXIT | 2048 | m/s^2 | ||
| accelerometer | KISTLER 8640A5 | K1:PEM-PSL_ACC_PERI_REFCAV | 2048 | m/s^2 | ||
| magnetometer | MAG13 MCL100 | K1:PEM-PSL_MAG_LASERRACK_(X|Y|Z) | 2048 | T | MAG13, WF, Distributor, Power removed temporary | |
| microphone | (B&K) 4188-A-021 | K1:PEM-PSL_MIC_CENTER | 2048 | Pa | ||
| accelerometer | KISTLER | K1:PEM-PSL_ACC_SIGNAL1 | 2048 | m/s^2 | ||
| accelerometer | KISTLER | K1:PEM-PSL_ACC_SIGNAL2 | 2048 | m/s^2 | 
CS(-2018/12/10-)
| PEM | Sensor | Channel name (_OUT_DQ) | sampling rate[Hz | Picture | Calibration(unit) | Memo(S number) | 
| microphone | AT-VD6 No.1 | K1:PEM-IMC_MIC_REFL | 2048 | [[|pic]] | Pa | |
| accelerometer | TEAC706 | K1:PEM-IMC_ACC_REFL_TABLE | 2048 | [[|pic]] | m/s^2 | |
| microphone | AT-VD6 No.2 | K1:PEM-IMC_MIC_TRANS | 2048 | [[|pic]] | Pa | |
| microphone | (B&K) 4188-A-021 | K1:PEM-IFI_MIC_REFL | 2048 | [[|pic]] | Pa | |
| accelerometer | TEAC710 | K1:PEM-IFI_ACC_REFL_TABLE | 2048 | [[|pic]] | m/s^2 | |
| microphone | (B&K) 4188-A-021 | K1:PEM-POP_MIC | 2048 | [[|pic]] | Pa | |
| accelerometer | TEAC710 | K1:PEM-POP_ACC_TABLE | 2048 | [[|pic]] | m/s^2 | |
| microphone | ACO 7146NL/4152 | K1:PEM-POS_MIC | 2048 | [[|pic]] | Pa | |
| accelerometer | TEAC710 | K1:PEM-POS_ACC_TABLE | 2048 | [[|pic]] | m/s^2 | |
| microphone | ACO 7146/4152 | K1:PEM-OMC_MIC | 2048 | [[|pic]] | Pa | |
| accelerometer | TEAC710 | K1:PEM-OMC_ACC_TABLE | 2048 | [[|pic]] | m/s^2 | |
| microphone | ACO 7146/4152 | K1:PEM-BS_MIC | 2048 | [[|pic]] | Pa | |
| microphone | ACO 7146/4152 | K1:PEM-SR_MIC | 2048 | [[|pic]] | Pa | 
Seismometer
| Snumber | Installed Place (ADC port) | Name | Channel name (OUT_DQ) | Unit | fs [Hz] | klog | 
| EXV (IX1, ADC0, 24-26) | Trillium 12QA | K1:PEM-IXV_GND_TR120Q_(X/Y/Z)_OUT_DQ | um/s | 512 | ||
| EXV (EX1, ADC0, 24-26) | Trillium 120QA | K1:PEM-EXV_GND_TR120Q_(X/Y/Z)_OUT_DQ | um/s | 512 | ||
| EYV (EY1, ADC0, 24-26) | Trillium 120QA | K1:PEM-EYV_GND_TR120Q_(X/Y/Z)_OUT_DQ | um/s | 512 | ||
| IXV (IX1, ADC0, 28-30) | Trillium 120QA | K1:PEM-IXV_GND_TR120QTEST_(X/Y/Z)_OUT_DQ | um/s | 512 | ||
| MCe (IOO1, ADC1, 4-6) | Trillium compact 120-SV1 | K1:PEM-IMC_GND_TR120C_MCE_(X/Y/Z)_OUT_DQ | um/s | 512 | 
 | |
| MCi (IOO1, ADC1, 0-2) | Trillium compact 120-SV1 | K1:PEM-IMC_GND_TR120C_MCI_(X/Y/Z)_OUT_DQ | um/s | 512 | 
 | |
| Fukuoka Univ. | Trillium compact 120-SV1 | ??? | --- | 512 | 
 | 
 Selfnoiseのグラフを載せる
 Selfnoiseのグラフを載せる 
Air Environment Sensors
| Snumber | Installed Place (ADC port) | Name | Channel name (xxx_OUT_DQ) | Unit | Sample rate [Hz] | 
| IXV (IX1, ADC1, 24-27) | No.5 | K1-IXV_WEATHER_{TEMP,HUMD,PRES}_ | Degree, %, Pa | 128 | |
| IYV (IY1, ADC1, 24-27) | 
 | 
 | 
 | 128 | |
| EXV (EX1, ADC1, 24-27) | --- | K1-EXV_WEATHER_{TEMP,HUMD,PRES}_ | Degree, %, Pa | 128 | |
| EYV (EY1, ADC1, 24-27) | --- | K1-EYV_WEATHER_{TEMP,HUMD,PRES}_ | Degree, %, Pa | 128 | |
| IXC (IX0, ADC0, 16-27?) | 
 | 
 | 
 | 128 | |
| IYC (IY0, ADC0, 20-23) | No6 | K1-IYC_WEATHER_{TEMP,HUMD,PRES}_ | Degree, %, Pa | 128 | 
Acording to JGW-T1809269, calibration factor from output voltage to each unit is given with
temp = ( Vout/78/0.001-100)/0.388 [deg_c] humd = (Vout/2)/5*100 [%] pressure = (Vout/2)/5*300 + 800 [hPa]
Then, "_GAIN" and "_OFFSET" parameters in cds filter of each channels are calculated by above equation with count value not voltage,
| Name | Value | Unit | 
| _TEMP_OFFSET | -1.278e4 | count | 
| _HUMD_OFFSET | 0.0 | count | 
| _PRES_OFFSET | 4.369e4 | count | 
| _TEMP_GAIN | 2.017e-2 | deg_c/count | 
| _HUMD_GAIN | 6.104e-3 | %/count | 
| _PRES_GAIN | 1.831e-2 | hPa/count | 
,where ransformation coefficient from voltage to adc count is given with c2V = 2.0 * 10/2**15 [V/count], because output signal from sensor is measured with single-end not differential. These parameters are managed by SDF with observe.snap. So, plase do not change this file.  
  Place   Sensor   Channel name   picture   Memo   IX0   Temporary   K1:PEM-IX0_SENSOR(1-12)   pic   Will be removed  
  Place   Sensor   Channel name   picture   Memo   IY0   Temporary   K1:PEM-IY0_SENSOR(1-12)   pic   Will be removed  
 
 2018/12/03 Update, miyo Temporary channels in IX0
   
   
Temporary channels in IY0
   
   
SDF
latest snapfile