Summary of results for the acoustic injection

  • Yokozawa injected the better interferometer condition
  • Washimi-san evaluated the noise projection

Acoustic injection to REFL table

  • Date : 7th Mar. 2020
  • klog13382

  • After changing the sampling rate of the portable PEMs
  • IMC output power 3.4W
  • REFL PDA1DC ~7mW
  • injection time : 1267565800-1267565900
  • silent run : 1267565900-1267566200
  • Results : 13415

    • There seems to be several peaks
      • 250Hz, 265Hz, 274Hz, 276Hz, 279Hz, 282Hz, 296Hz
        • Hint in the ISS table(QPD1 pit)?
      • 320Hz(floor), 332Hz,
        • Hint in the ISS table(QPD1 pit)?
      • 350-370Hz, 394Hz
        • PR3 oplev yaw?
      • 510-530Hz
        • Similar behavior in the IMC refl accelerometer (Hint in the IMC refl)

Noise projection of acoustic injection to REFL table

Acoustic injection to POP table amd PR2

  • Date : 11th Mar. 2020
  • klog13458

  • IMC output power 3.0W
  • REFL PDA1DC ~8mW
  • injection time : 1267904400 - 1267904500
  • silent run : 1267904600-1256904700
  • Results : klog13464

    • 75Hz
    • 330-400Hz
    • 710-720Hz
    • We don't have a hint for them

    Noise projection of acoustic injection to POP table