Size: 205
Comment:
|
Size: 647
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
== Summary of results for the acoustic injection == | = Summary of results for the acoustic injection = |
Line 6: | Line 6: |
=== Acoustic injection to REFL table === | == Acoustic injection to REFL table == * Date : 7th Mar. 2020 * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=13382 | klog13382]] * After changing the sampling rate of the portable PEMs * IMC output power 3.4W * REFL PDA1DC ~7mW * injection time : 1267565800-1267565900 * silent run : 1267565900-1267566200 [[attachment:13407_20200309024834_202003096.png|{{attachment:13407_20200309024834_202003096.png|Noise projection of acoustic injection to REFL table|width="600"}}]] |
Summary of results for the acoustic injection
- Yokozawa injected the better interferometer condition
- Washimi-san evaluated the noise projection
Acoustic injection to REFL table
- Date : 7th Mar. 2020
- After changing the sampling rate of the portable PEMs
- IMC output power 3.4W
- REFL PDA1DC ~7mW
- injection time : 1267565800-1267565900
- silent run : 1267565900-1267566200