== Hammering test == == - Hammering test ==
Line 5: Line 5:
=== '''Task list (Done)''' === === Task list (Done) ===
Line 9: Line 9:
  * Reported later, the main reason the vibration to the OMC legs for the optical table inside the vacuum   * Reported later, the main reason is the vibration to the OMC legs for the optical table inside the vacuum
Line 12: Line 12:
  *   * Reported later, the main reason is the vibration to the OMC legs for the optical table inside the vacuum
Line 14: Line 14:
  * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=13105|klog13105]]
  * Now we didn't use the AS PD signals for interferometer control
  * There was possibility that the reflection light from AS table make dirty scattering light
  * Shadowed between the OMC viewport and AS table, but we couldn't see the clear noise reduction
  * Also, when we added vibration to the OMC viewport, we couldn't detect the noise increasing.
Line 22: Line 27:
== PEM injection == == - PEM injection ==

Memo for Commissioning break (Mar. 2020)

- Hammering test

Task list (Done)

  • Hammering test of the OMC chamber (Done 22nd Feb.)
    • klog13105

    • There is excess in the sensitivity between 100 Hz to 400 Hz
    • Reported later, the main reason is the vibration to the OMC legs for the optical table inside the vacuum
  • Hammering test AS table (Done 22nd Feb.)
    • klog13105

    • Reported later, the main reason is the vibration to the OMC legs for the optical table inside the vacuum
  • Reflection light check (Done 22nd Feb.)
    • klog13105

    • Now we didn't use the AS PD signals for interferometer control
    • There was possibility that the reflection light from AS table make dirty scattering light
    • Shadowed between the OMC viewport and AS table, but we couldn't see the clear noise reduction
    • Also, when we added vibration to the OMC viewport, we couldn't detect the noise increasing.

Task list (Partially done)

Task list (todo ; must items)

Task list (todo ; if possible)

- PEM injection