Differences between revisions 1 and 6 (spanning 5 versions)
Revision 1 as of 2019-11-05 16:12:45
Size: 84
Comment:
Revision 6 as of 2019-11-05 18:17:50
Size: 5351
Comment:
Deletions are marked like this. Additions are marked like this.
Line 4: Line 4:
 * Attend:  * Attend:Yokozaqwa, TNTanaka, Fujikawa, Ohkawa, Washimi, Mori, Kozakai, Yamada, Akutsu, Kaihotsu

=== Agenda ===
 
 * General issue

  * Interferometer status
   * Now, we can lock the interferometer stably
   * ISS(Intensity Stabilization System) was implemented, better sensitivity
   * Long silent run at 2nd Nobember ([[http://klog.icrr.u-tokyo.ac.jp/osl/?r=11312|klog11312]])
   * See the detail in [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/DET/RUN/MORNINGRUN2019|url]]
   * Silent run -> Some excitation(including calibration line) -> PEM injection -> Hardware injection

 * PTEP paper
  * [kagra 03133]
  * KAGRA Overview papers
  * Overview of KAGRA : (3) Detchar, calibration, physical environment, data quality

 * Next F2F meeting
  * RESCEU
  * 4th and 5th Dec., 2019
  * 1 slot Washimi-san will have a talk
  * If you plan to write master/doctor thesis, please let me know

 * Chrome Book project (Portable PEM researcher)
  * http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/PEM/Portable
  * We prepared two PEM Chromebook
  * Start writing paper (PTEP?)

 * PEM injection
  * Shaker injection1 (TTanaka, Yokozawa)
  * Shaker injection2 (Okutomi, Fabian)
  * acoustic injection (TTanaka, Yokozawa)
  * magnetic field injection (Niigata Tanaka, Fujikawa, Yokozawa)
  * RF injection (TTanaka, Washimi)

 * Weekly PEM measurement
  * Friday is weekly PEM measurement
  * Understanding the effect of the instruments, search the origin of noise, and so on
  * Tentative : New vacuum pump, 18V DC noise(24Hz), Cryochamber vibration(46Hz), FFU, Noise search

 * Database for the KAGRA characteristic lines
   * [[https://www.icrr.u-tokyo.ac.jp/~yokozawa/KAGRA_line_database/index.html|url]]

 * Visitors from LV
   * Anamaria from Livingston : 18 - 29 Nov.
   * Federico, Irene, Camilla (input optics) + Francesca from Virgo : 11/18-12/7 (2 weeks@KAGRA, 1 weeks@NAOJ)

 * Each progress

  * Yokozawa
   * Current serious noises
    * 24Hz noise (100V AC + AA?)
    * MICH control noise
    * Coherent with ITMX MN YAW
    * Coherence with ITMY TM PIT
   * Daily summary page

  * Washimi
   * Summary of coherence study between PEMs and DARM displacement
    * 週末のFPMIとPEMのcoherenceを見ていった。
    * 11HzのEXCにmagとの相関が見えたのですが、みに行った時間にはなかった、lockとの関係がある?
    * Pcal RxPD 1.3HzはETMYのgasが励起していて、それが影響していた可能性がある。->long oplevとして見えた。
    * 24Hzはrack noise
    * 44,45Hz Compressor or FFU?
    * Compressor sound make44Hz, 46Hz and 56Hz -> stop during observation, check the coherence with FPMI signal
    * 60Hz EXC magが大きい、GNDが汚れている可能性が高い
    * PSL acousticは複数micを置いて場所を見る。
    * ~110Hzはlaser amp
    * 840Hz IMC refl
    * Priorityを決める、Identifyとhuntingはちがう。

  * Washimi, Yamada, TTanaka
   * IXC vibration -> See the Yamada-san's slide
     * Identify the origin of the frequency noise
     * 42Hzパイロンの共振
     * 44Hz 気まぐれcompressor
     * 46.125Hz
     * 54.125Hz きまぐれcompressor
     * 58音?
     * acoustic injectionで盛り上がるpeakがある。散乱光の影響か?
     * IXCとDARMのcoherenceを取れるdataが木曜日の夜にすこしだけある。
     * center areaのmicとDARMに7Hz coherence、エンドには出ない
     * ITMX MN Pとcoherence <20Hz
     * TM oplev定盤に置いたACCとDARMにcoherenceがある、46Hz、いいヒント
     * MICとITMX PEMのcoherence、46Hzにmic vs TM oplev、lengthにあるかも
     * プシュー有り無しで比較したい。
     * compressor, 2分静か、30秒かたかた、10分、プシュー

  * Kozakai
   * Trigger analysis with silent run
   * glitch plotがautoで走ったので、Yuzu summary pageを見てみてください。
   * glitch plot catalog
   * 磁束計で見えているのと地震計で見えているものがある、何処のsuspensionが影響が大きいかなどもわかると思う。
   * Fabianがコメントしていた、oplev jumpは影響あるか?->あとでみてみる

  * TTanaka(ICRR), Washimi, TTanaka(Niigata), Yamada
   * Acoustic injection with FPMI

  * Mori, Nakayama
   * Vacuum pump vibration
   * 6箇所のvacuum pump(dry、turbo)を止めた、ionは止めていない、観測中もionだけは着けておくと思われる。
   * turbo pump on/offでの振動の比較
   * Pressureは2倍になったが、影響はなさそう、outor gasは少ないと思われる。
   * 振動が少ないポンプ
   * ポンプ由来の振動ピークと音響ピークを同定できた
   * 200Hzがfloorがすこしちがう、OFFの方が多いから何かhintになると思う。214と216Hz。253Hzはonoff関係なく存在した。
   * chiller付きのpumpではない

  * Fujikawa, Mori
   * fujimopy [[attachment:PEMmtg_191105fmpy.pdf]]
   * Line amplitude web page

  * Fujikawa, Washimi
   * Lock loss study

  * TTanaka(Niigata)
   * Preparation of the coil
   * 24Hz noise situation

  * etc

Minute of PEM meeting

  • Date: 2019/11/05 17:00-18:00(JST)
  • Attend:Yokozaqwa, TNTanaka, Fujikawa, Ohkawa, Washimi, Mori, Kozakai, Yamada, Akutsu, Kaihotsu

Agenda

  • General issue
    • Interferometer status
      • Now, we can lock the interferometer stably
      • ISS(Intensity Stabilization System) was implemented, better sensitivity
      • Long silent run at 2nd Nobember (klog11312)

      • See the detail in url

      • Silent run -> Some excitation(including calibration line) -> PEM injection -> Hardware injection

  • PTEP paper
    • [kagra 03133]
    • KAGRA Overview papers
    • Overview of KAGRA : (3) Detchar, calibration, physical environment, data quality
  • Next F2F meeting
    • RESCEU
    • 4th and 5th Dec., 2019
    • 1 slot Washimi-san will have a talk
    • If you plan to write master/doctor thesis, please let me know
  • Chrome Book project (Portable PEM researcher)
  • PEM injection
    • Shaker injection1 (TTanaka, Yokozawa)
    • Shaker injection2 (Okutomi, Fabian)
    • acoustic injection (TTanaka, Yokozawa)
    • magnetic field injection (Niigata Tanaka, Fujikawa, Yokozawa)
    • RF injection (TTanaka, Washimi)
  • Weekly PEM measurement
    • Friday is weekly PEM measurement
    • Understanding the effect of the instruments, search the origin of noise, and so on
    • Tentative : New vacuum pump, 18V DC noise(24Hz), Cryochamber vibration(46Hz), FFU, Noise search
  • Database for the KAGRA characteristic lines
  • Visitors from LV
    • Anamaria from Livingston : 18 - 29 Nov.
    • Federico, Irene, Camilla (input optics) + Francesca from Virgo : 11/18-12/7 (2 weeks@KAGRA, 1 weeks@NAOJ)
  • Each progress
    • Yokozawa
      • Current serious noises
        • 24Hz noise (100V AC + AA?)
        • MICH control noise
        • Coherent with ITMX MN YAW
        • Coherence with ITMY TM PIT
      • Daily summary page
    • Washimi
      • Summary of coherence study between PEMs and DARM displacement
        • 週末のFPMIとPEMのcoherenceを見ていった。
        • 11HzのEXCにmagとの相関が見えたのですが、みに行った時間にはなかった、lockとの関係がある?
        • Pcal RxPD 1.3HzはETMYのgasが励起していて、それが影響していた可能性がある。->long oplevとして見えた。

        • 24Hzはrack noise
        • 44,45Hz Compressor or FFU?
        • Compressor sound make44Hz, 46Hz and 56Hz -> stop during observation, check the coherence with FPMI signal

        • 60Hz EXC magが大きい、GNDが汚れている可能性が高い
        • PSL acousticは複数micを置いて場所を見る。
        • ~110Hzはlaser amp
        • 840Hz IMC refl
        • Priorityを決める、Identifyとhuntingはちがう。
    • Washimi, Yamada, TTanaka
      • IXC vibration -> See the Yamada-san's slide

        • Identify the origin of the frequency noise
        • 42Hzパイロンの共振
        • 44Hz 気まぐれcompressor
        • 46.125Hz
        • 54.125Hz きまぐれcompressor
        • 58音?
        • acoustic injectionで盛り上がるpeakがある。散乱光の影響か?
        • IXCとDARMのcoherenceを取れるdataが木曜日の夜にすこしだけある。
        • center areaのmicとDARMに7Hz coherence、エンドには出ない
        • ITMX MN Pとcoherence <20Hz

        • TM oplev定盤に置いたACCとDARMにcoherenceがある、46Hz、いいヒント
        • MICとITMX PEMのcoherence、46Hzにmic vs TM oplev、lengthにあるかも
        • プシュー有り無しで比較したい。
        • compressor, 2分静か、30秒かたかた、10分、プシュー
    • Kozakai
      • Trigger analysis with silent run
      • glitch plotがautoで走ったので、Yuzu summary pageを見てみてください。
      • glitch plot catalog
      • 磁束計で見えているのと地震計で見えているものがある、何処のsuspensionが影響が大きいかなどもわかると思う。
      • Fabianがコメントしていた、oplev jumpは影響あるか?->あとでみてみる

    • TTanaka(ICRR), Washimi, TTanaka(Niigata), Yamada
      • Acoustic injection with FPMI
    • Mori, Nakayama
      • Vacuum pump vibration
      • 6箇所のvacuum pump(dry、turbo)を止めた、ionは止めていない、観測中もionだけは着けておくと思われる。
      • turbo pump on/offでの振動の比較
      • Pressureは2倍になったが、影響はなさそう、outor gasは少ないと思われる。
      • 振動が少ないポンプ
      • ポンプ由来の振動ピークと音響ピークを同定できた
      • 200Hzがfloorがすこしちがう、OFFの方が多いから何かhintになると思う。214と216Hz。253Hzはonoff関係なく存在した。
      • chiller付きのpumpではない
    • Fujikawa, Mori
    • Fujikawa, Washimi
      • Lock loss study
    • TTanaka(Niigata)
      • Preparation of the coil
      • 24Hz noise situation
    • etc

KAGRA/Subgroups/PEM/Meeting/191105/Minute (last edited 2019-11-05 18:36:36 by TakaakiYokozawa)