Line 1: Line 1:
= Minute of PEM meeting =
----
= Minute of LVK PEM meeting =
Line 4: Line 3:
 * Date: 2019/9/26 16:00-18:00(JST)
 * Attendance:
 * Date: 2019/11/26 16:00-18:00(JST)
Line 11: Line 9:
 * LIGO PEM report
  * LIGO Livingston O3 Commissioning Break (and other fun stuff) (Anamaria) [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11012|JGW-G1911012]]
 * Virgo ENV report
  * October 2019 Virgo commissioning break: report on activities (focus on Noise Hunting) (Federico) [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11010|JGW-G1911010]]
Line 12: Line 14:
 * KAGRA detector status & Update of the KAGRA PEM from last meeting (Yokozawa)[[attachment:PEM_191126.pdf|pdf]]
  * Change the accelerometers to beam direction
 * Status of Environmental noise hunting in KAGRA (Washimi)[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11013]]
  * Slow Environmental Monitor should monitor not only day but also week/monty -> Already monitored
 * Brief summary of the DetChar activity Slides(Kozakai)[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11011|pdf]]
  * Can anyone use spectrogram tool? yes
  * Make frame file with selected channel -> Another issue
 * Seismic motion measurement(Francesca)[[attachment:KAGRA_francesca.pdf|pdf]]
 * Status of the PEM injection in KAGRA (TTanaka)[[attachment:meeting191126.pdf|pdf]]
  * Not distinguish coherence and incoherence for acoustic injection
  * Check different amplitude injection and check the linearity of the significance
  * Use aqccelerometer instead of the microphone
  * Reducing the uncertainty for the injection point. Wide injection->local injection
 * others
  * KAGRA detector status & Update of the KAGRA PEM from last meeting (Yokozawa)[[attachment:PEM_191126.pdf|pdf]]
   * Change the accelerometers to beam direction
  * Status of Environmental noise hunting in KAGRA (Washimi)[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11013|JGW-G1911013]]
   * Slow Environmental Monitor should monitor not only day but also week/monty -> Already monitored
  * Brief summary of the DetChar activity Slides(Kozakai)[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11011|JGW-G1911011]]
   * Can anyone use spectrogram tool? yes
  * Make frame file with selected channel -> Another issue
  * Seismic motion measurement(Francesca)[[attachment:KAGRA_francesca.pdf|pdf]]
  * Status of the PEM injection in KAGRA (TTanaka)[[attachment:meeting191126.pdf|pdf]]
   * Not distinguish coherence and incoherence for acoustic injection
   * Check different amplitude injection and check the linearity of the significance
   * Use aqccelerometer instead of the microphone
  * Reducing the uncertainty for the injection point. Wide injection->local injection
 

Minute of LVK PEM meeting

  • Date: 2019/11/26 16:00-18:00(JST)
  • English meeting
  • Join : Yokozawa, Washimi, Federico, Taiki Tanaka, Takaaki Tanaka, Fujikawa, Michimura, Anamaria, Kokeyama , Francesca, Camilla, Kozakai, Irene, Akutsu, Yamat, Mori, Oshino

Agenda

  • LIGO PEM report
    • LIGO Livingston O3 Commissioning Break (and other fun stuff) (Anamaria) JGW-G1911012

  • Virgo ENV report
    • October 2019 Virgo commissioning break: report on activities (focus on Noise Hunting) (Federico) JGW-G1911010

  • KAGRA PEM reports
    • KAGRA detector status & Update of the KAGRA PEM from last meeting (Yokozawa)pdf

      • Change the accelerometers to beam direction
    • Status of Environmental noise hunting in KAGRA (Washimi)JGW-G1911013

      • Slow Environmental Monitor should monitor not only day but also week/monty -> Already monitored

    • Brief summary of the DetChar activity Slides(Kozakai)JGW-G1911011

      • Can anyone use spectrogram tool? yes
      • Make frame file with selected channel -> Another issue

    • Seismic motion measurement(Francesca)pdf

    • Status of the PEM injection in KAGRA (TTanaka)pdf

      • Not distinguish coherence and incoherence for acoustic injection
      • Check different amplitude injection and check the linearity of the significance
      • Use aqccelerometer instead of the microphone
      • Reducing the uncertainty for the injection point. Wide injection->local injection