Size: 2163
Comment:
|
Size: 2156
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 12: | Line 12: |
* There is still some peaks in the lower frequency * Mostly AS PD noise at higher frequency * Peaks appeared at higher frequency |
|
Line 15: | Line 18: |
* F2F meeting (4th and 5th Dec., 2019 @ RESCEU) [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/LCGT/Meeting/f2f/2019Dec]] * Washimi (PEM status) * Miyo (doctoral thesis) * TTanaka (master thesis) |
|
Line 20: | Line 19: |
* registration : -12/3 14:00 | * Yokozawa, TTanaka |
Line 24: | Line 23: |
* Where is the PZT shaker driver? * Acoustic injection -> Shaker injection |
|
Line 25: | Line 26: |
* PSL, REFL and AS table injection * Analysis is ongoing |
|
Line 26: | Line 29: |
* Acoustic injection to the PSL room | * Effect of the air cooler magnetic field * AS, REFL table injection |
Line 29: | Line 33: |
* Thank you for Virgo PEM member! | |
Line 31: | Line 36: |
* Materials * If you planed to by the PEM materials, please let me know as soon as possible * Weekly PEM measurement * Understanding the effect of the instruments, search the origin of noise, and so on * Tentative : Air cooler, ground, air compressor * Database for the KAGRA characteristic lines * [[https://www.icrr.u-tokyo.ac.jp/~yokozawa/KAGRA_line_database/index.html|url]] * Fixed bugs |
* PEM measurement * Sunday morning : PEM injection * 10th Dec. : Xend environmental check * Someday : Effect of the sound to DARM displacement * Someday : Environmental check around BS (including the POP) * Someday : Evaluation of the table cover * Someday : SR2 and SR3 optical lever (Reflection light from SRM?) |
Line 43: | Line 45: |
* Anamaria from Livingston : 18 - 29 Nov. * Federico, Irene, Camilla (input optics) + Francesca from Virgo : 11/26-12/7 (2 weeks@KAGRA, 1 weeks@NAOJ) * Fujikawa, TNTanaka 11/24-12/10 |
* Adam, Sheila (-12/13) * Camilla (-12/20) |
Line 50: | Line 51: |
* Short report about newtonian noise measurement(Virgo PEM effort) * Short report about jitter noise at PSL room(Camilla effort) |
|
Line 51: | Line 54: |
* MICH control noise * Lock state vs EXC magnetometer * PSL room |
|
Line 56: | Line 56: |
* Slow monitor page | |
Line 68: | Line 67: |
* Lock loss study * fujimopy * Line amplitude web page |
* Lock loss study * fujimopy [[attachment:PEMmtg_191211lock.pdf]] |
Line 73: | Line 71: |
* Preparation of the coil * IXC compressor study |
* Magnetic field from air cooler and compressor * Magnetic field injection to AS and REFL table |
Weekly PEM meeting
- 2019/12/10(Tue) 16:00-(JST)
- Regular meeting meeting (Japanese)
Web meeting with Zoom2 (Zoom2)
Agenda
- General issue
- Interferometer status
- Detection range is about 10kpc (or 30kpc(?))
- There is still some peaks in the lower frequency
- Mostly AS PD noise at higher frequency
- Peaks appeared at higher frequency
- December 17-24 24h engineering run
- Interferometer status
- Conference
- JPS (2010/3/16-19 @ Nagoya)
- Yokozawa, TTanaka
- JPS (2010/3/16-19 @ Nagoya)
- PEM injection
- Shaker injection1 (TTanaka, Yokozawa)
- Where is the PZT shaker driver?
Acoustic injection -> Shaker injection
- acoustic injection (TTanaka, Yokozawa)
- PSL, REFL and AS table injection
- Analysis is ongoing
- magnetic field injection (Niigata Tanaka, Fujikawa, Yokozawa)
- Effect of the air cooler magnetic field
- AS, REFL table injection
- Shaker injection1 (TTanaka, Yokozawa)
- Newtonian noise measurement
- Thank you for Virgo PEM member!
- Francesca mainly measured the newtonian noise
- PEM measurement
- Sunday morning : PEM injection
- 10th Dec. : Xend environmental check
- Someday : Effect of the sound to DARM displacement
- Someday : Environmental check around BS (including the POP)
- Someday : Evaluation of the table cover
- Someday : SR2 and SR3 optical lever (Reflection light from SRM?)
- Visitors from LV
- Adam, Sheila (-12/13)
- Camilla (-12/20)
- Each progress
- Yokozawa
- Short report about newtonian noise measurement(Virgo PEM effort)
- Short report about jitter noise at PSL room(Camilla effort)
- Current serious noises
- Washimi
- Lockloss study
- Volt monitor for the optical table
- Polish-up of Acuostic reverberation time (on-going)
- Kozakai
- Trigger analysis with silent run
- TTanaka(ICRR)
- Acoustic injection with FPMI
- Fujikawa
- Lock loss study
fujimopy PEMmtg_191211lock.pdf
- TTanaka(Niigata)
- Magnetic field from air cooler and compressor
- Magnetic field injection to AS and REFL table
- etc
- Yokozawa