Size: 2268
Comment:
|
Size: 4547
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 12: | Line 12: |
* Observation run started without O3 joint observation | * Observation run started without O3 joining |
Line 16: | Line 16: |
* Duty cycle ~65% * We need ~1h for initial alignment |
|
Line 18: | Line 20: |
* PEM plan remaining two weeks | * Maintenance day (2020/03/03) * I asked SEO about following works * If you have more request, please let Yokozawa or Washimi-san know first. * 1. (Highest priority from PEM team) * Go inside the mine and move the PEMs placed at OMC legs to next noise target. * Next target is under discussion(Candidate is IXC area). * Change the position of the speaker to around POP area * We don’t need the interferometer during this work. * 1 hour work. * Yokozawa, Washimi * 2. (If possible) * Go inside the mine. * Turned on the all FFUs(~5min) to evaluate the noise from FFUs. * If we can observe the noise from FFUs in the sensitivity curve, we can consider next target. * If we cannot observe the noise, current noise limit may not come from the sound inside the clean area. * We need the interferometer during this work. * 10min work * Yokozawa, Washimi * 3. (If possible) * Go inside the mine * Hammering test to the cryochambers and ducts and so on to investigate the vibration effects. * We need the interferometer during this work. * Also, the hammering test PR and IMC area is essential * PEM tasks during observation run |
Line 20: | Line 46: |
* Shaker and Acoustic injection * PSL, REFL and AS table injection again |
* Shaker and Acoustic injection * PSL, REFL and AS table injection again * Saturday afternoon(2/29) between the lock loss and observing state |
Line 23: | Line 50: |
* [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/PEM/Meeting/200121/Minute|20/01/21 Minute]] * Hammering test @ Y-end : around 2/15 ([[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11419|JGW-G2011419]]) |
* [[http://gwwiki.icrr.u-tokyo.ac.jp/JGWwiki/KAGRA/Subgroups/PEM/Meeting/200121/Minute|20/01/21 Minute]] * Hammering tests to the OMC, SRs, BS and PR2 were done [http://klog.icrr.u-tokyo.ac.jp/osl/?r=13138|klog13138] * There is large excitation when we touched the legs of the OMC chamber * But we concluded that vibration of the logs of the OMC chamber were not the dominant noise source in the current sensitivity * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=13152|klog13152]] and [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=13199|klog13199]] * Next target of investigation is the duct between PR2 and BS * Candidate of the 60-90Hz noise |
Line 26: | Line 58: |
* Turning off the instruments was completed * Check the sensitivity when we turned on the FFU * Microphone spectrum comparison |
* This may not be used during O3 run, but it is good practice toward the O4 run * Help the RRT(Rapid Response Team, quick discussion for the event submitted to the GraceCB) * Evaluate the effect of the FFUs and vacuum pumps by turning on during interferometer lock * If the excitation detected, we have to consider about the FFUs which are working. |
Line 30: | Line 63: |
* Yend chamber? * Around OMC, AS table? |
* Now, the legs of the OMC * Next target is IXC or PR2-BS or somewhere PRs or IMC area. |
Line 34: | Line 67: |
* [[https://sites.google.com/view/ugapw2020/home|地下宇宙若手研究会]]@茂住 (2020/2/22-24) * JPS (2020/3/16-19 @ Nagoya) |
* JPS (2020/3/16-19 @ Nagoya)-> Cancelled |
Line 39: | Line 71: |
* Miyoki-san suggested to visit Virgo to join the commissioning as the PEM team * If you have interested in please let me know * Other interesting conference? Deadline is 29th Feb. |
|
Line 48: | Line 83: |
* Earlier time is better? | |
Line 52: | Line 88: |
* What should we do this week * Tuned off the FFUs and vacuum pumps * Temperature and GAS drift |
* Discussion about the list of the general issue * Current line noise identification * PEM coherence search to the longer locked data * GND issue |
Line 57: | Line 94: |
* Infrasound measurements [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=13004|klog13004]], [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12859|klog12859]] * SEM updates[[https://www.icrr.u-tokyo.ac.jp/~washimi/KAGRA/SEM/]] * PEM MAP update [[https://www.icrr.u-tokyo.ac.jp/~washimi/KAGRA/PEM/PEMmap/]] |
* Investigation the environment around the OMC area * Investigation the water pump * |
Line 61: | Line 98: |
* etc | * TTanaka * 23.3Hz noise investigation * Yuzurihara * Updated Pastavi * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=13194 | Pastai update : Added mass-range estimation]] * [[http://klog.icrr.u-tokyo.ac.jp/osl/?r=12872 | Pastai update : Add button for h(t) channel, Taking overlap in PSD estimation]] |
Weekly PEM meeting
- 2020/02/28(Fri) 16:00-(JST)
- Regular meeting meeting (Japanese)
Web meeting with Zoom2 (Zoom2)
Agenda
General issue
- Interferometer status
- Observation run started without O3 joining
- Average ~250kpc BNS detection range
- Lock duration is 1h -4h
- Alignment dependence
- Duty cycle ~65%
- We need ~1h for initial alignment
- 3/10 - commissioning break(?)
- Maintenance day (2020/03/03)
- I asked SEO about following works
- If you have more request, please let Yokozawa or Washimi-san know first.
- 1. (Highest priority from PEM team)
- Go inside the mine and move the PEMs placed at OMC legs to next noise target.
- Next target is under discussion(Candidate is IXC area).
- Change the position of the speaker to around POP area
- We don’t need the interferometer during this work.
- 1 hour work.
- Yokozawa, Washimi
- 2. (If possible)
- Go inside the mine.
- Turned on the all FFUs(~5min) to evaluate the noise from FFUs.
- If we can observe the noise from FFUs in the sensitivity curve, we can consider next target.
- If we cannot observe the noise, current noise limit may not come from the sound inside the clean area.
- We need the interferometer during this work.
- 10min work
- Yokozawa, Washimi
- 3. (If possible)
- Go inside the mine
- Hammering test to the cryochambers and ducts and so on to investigate the vibration effects.
- We need the interferometer during this work.
- Also, the hammering test PR and IMC area is essential
- PEM tasks during observation run
- PEM injection
- Shaker and Acoustic injection
- PSL, REFL and AS table injection again
- Saturday afternoon(2/29) between the lock loss and observing state
- Shaker and Acoustic injection
- Hammering test
Hammering tests to the OMC, SRs, BS and PR2 were done [http://klog.icrr.u-tokyo.ac.jp/osl/?r=13138|klog13138]
- There is large excitation when we touched the legs of the OMC chamber
- But we concluded that vibration of the logs of the OMC chamber were not the dominant noise source in the current sensitivity
- Next target of investigation is the duct between PR2 and BS
- Candidate of the 60-90Hz noise
- Discussion about the PEM flags
- This may not be used during O3 run, but it is good practice toward the O4 run
- Help the RRT(Rapid Response Team, quick discussion for the event submitted to the GraceCB)
- Evaluate the effect of the FFUs and vacuum pumps by turning on during interferometer lock
- If the excitation detected, we have to consider about the FFUs which are working.
- Set portable PEMs to the some point for the O3 run
- Now, the legs of the OMC
- Next target is IXC or PR2-BS or somewhere PRs or IMC area.
- PEM injection
- Conference
JPS (2020/3/16-19 @ Nagoya)-> Cancelled
- Yokozawa, TTanaka
F2F (2020/4/17-20 @ Kashiwa) wiki
- Core to core application
- Miyoki-san suggested to visit Virgo to join the commissioning as the PEM team
- If you have interested in please let me know
- Other interesting conference? Deadline is 29th Feb.
- Application of the author list
- [kagra 03345] from Somiya-san e-mail
- Deadline : 29th Feb.
- エフォート率など相談がありましたら横澤までご連絡ください。
- PEM meeting
- Tuesday may be a maintenance day
- I want to move PEM meeting to Friday and discuss what should we do during maintenance day.
- Earlier time is better?
Each progress
- Yokozawa
- Discussion about the list of the general issue
- Current line noise identification
- PEM coherence search to the longer locked data
- GND issue
- Washimi
- Investigation the environment around the OMC area
- Investigation the water pump
- TTanaka
- 23.3Hz noise investigation
- Yuzurihara