⇤ ← Revision 1 as of 2020-03-21 04:05:51
Size: 1277
Comment:
|
← Revision 2 as of 2020-03-21 04:16:10 ⇥
Size: 2488
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
== Weekly PEM meeting == * 2020/03/20(Tue) 14:00-(JST) * Regular meeting meeting (Japanese) * Web meeting with Zoom2 ([[https://zoom.us/j/6676627462|Zoom2]]) |
|
Line 2: | Line 6: |
* member : Nagano, Ohkawa, Takano, RTakahashi, Washimi, Tomaru, Kozakai, Yokozawa | |
Line 7: | Line 10: |
* Sorry for the meeting at the national holiday. |
|
Line 10: | Line 11: |
* Two weeks observation was finished * Maximum 594kpc BNS detection range * Maximum Lock duration is over 10h |
|
Line 16: | Line 14: |
* DRFPMI lock trial | |
Line 20: | Line 19: |
* 70 - 100Hz : Unknown | |
Line 36: | Line 34: |
==== Minutes ==== * Yokozawa will make the todo list for Saturday and Sunday hammering test * Check again the IMC gate valve (Open and Close lock trial with close the gate valve, ...) * Discussed about the offline subtraction (including to online?) * Hammering test and acoustic injection to REFL table area * There is coherence with the DARM, PRCL. Not so in CARM, MICH * Laser fluctuation * The hammering effect is largest around IMC bellows. And effect became smaller when we hammered far from MCF chamber. * The effect of the hammering to MCF chamber itself is not so large * From the noise projection to the accelerometer, the dominant vibration source would come from acoustic * We turned out 500Hz may come from REFL table, but we didn't identify which optic may make * NINJA * Only work in the k1ctr7 (Environmental dependence) * Investigation the scattering light effect by injecting the low frequency fluctuation * So called shoulder noise * [[https://logbook.virgo-gw.eu/virgo/?r=38028|Virgo work by Nagano-san]] * Including to scheduling * camera setup inside the vacuum |
Weekly PEM meeting
- 2020/03/20(Tue) 14:00-(JST)
- Regular meeting meeting (Japanese)
Web meeting with Zoom2 (Zoom2)
- member : Nagano, Ohkawa, Takano, RTakahashi, Washimi, Tomaru, Kozakai, Yokozawa
General issue
- Interferometer status
- 3/10 - commissioning break started
- Noise projection
- Hammering test (Sat. and Sun. morning time)
- DRFPMI lock trial
- Noise budget was (almost) completed
- Below 70 Hz : Type-A control noise
- 100 - 200 : Actuator DAC noise(?)
- 200 - 400 : Acoustic noise around IMM area (?)
- Above 400 Hz : Shot noise, Laser noise(Intensity, frequency)
- 3/10 - commissioning break started
- PEM tasks in March
- PRM booth MICを常設にしませんか? (IOO1 BNC ch11かch12で)
Each progress
- Discussion about the list of the general issue (Yokozawa)
- Acoustic injection and hammering test result (Washimi)
Data and Results list : KAGRA/Subgroups/PEM/PEMinjection/O3
KAGRA Noise INJection Analizer; NINJA : JGW-T2011564
- Plan of the lock loss study (Fujikawa)
Minutes
- Yokozawa will make the todo list for Saturday and Sunday hammering test
- Check again the IMC gate valve (Open and Close lock trial with close the gate valve, ...)
- Discussed about the offline subtraction (including to online?)
- Hammering test and acoustic injection to REFL table area
- There is coherence with the DARM, PRCL. Not so in CARM, MICH
- Laser fluctuation
- The hammering effect is largest around IMC bellows. And effect became smaller when we hammered far from MCF chamber.
- The effect of the hammering to MCF chamber itself is not so large
- From the noise projection to the accelerometer, the dominant vibration source would come from acoustic
- We turned out 500Hz may come from REFL table, but we didn't identify which optic may make
- There is coherence with the DARM, PRCL. Not so in CARM, MICH
- NINJA
- Only work in the k1ctr7 (Environmental dependence)
- Investigation the scattering light effect by injecting the low frequency fluctuation
- So called shoulder noise
- Including to scheduling
- camera setup inside the vacuum