Size: 737
Comment:
|
Size: 1453
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
<<TableOfContents(3)>> |
|
Line 3: | Line 5: |
== Check items on Hardware == === Cable connection === * Resistance (Ohom) * Continuity (O/X) |
|
Line 8: | Line 6: |
=== Calibration (LVDT, ACC) === * Calibration (plot, polarity, coefficient) * Sensor noise (plot) |
{{attachment:VISworkflow-Overview.png|width=400}} |
Line 12: | Line 8: |
=== Working point and dynamic range with FR, Limit SW === * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) |
== A: Design phase == === Templates for A === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
Line 18: | Line 12: |
=== Tuned frequencies of GAS Filter/IP === * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) |
=== A01 === * hoge == B: Installation phase == === Templates for B === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]] === B01 === * Cable connection * Resistance (Ohom) * Continuity (OK/NO) * Calibration (LVDT, ACC) * Calibration (plot, polarity, coefficient) * Sensor noise (plot) * Working point and dynamic range with FR, Limit SW * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) * Tuned frequencies of GAS Filter/IP * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) === B02 === === B03 === === B04 === == C: Integration phase == === Templates for C === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] === C01 === * Healthy check * Transfer function (plot) * Resonant frequencies (PreQUA) === C02 === ------ |
Line 24: | Line 61: |
* Transfer function (plot) * Resonant frequencies (PreQUA) |
* Transfer function (plot) * Resonant frequencies (PreQUA) |
Line 28: | Line 65: |
* RMS in spectrum (plot) | * RMS in spectrum (plot) |
Line 31: | Line 68: |
* Spectrum (plot) | * Spectrum (plot) |
Contents
Acceptance Test
A: Design phase
Templates for A
A01
- hoge
B: Installation phase
Templates for B
B01
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02
B03
B04
C: Integration phase
Templates for C
C01
- Healthy check
- Transfer function (plot)
- Resonant frequencies (PreQUA)
C02
Check items on Software (Control)
Healthy check template
- Transfer function (plot)
- Resonant frequencies (PreQUA)
Damping time
- RMS in spectrum (plot)
Noise budget
- Spectrum (plot)