Differences between revisions 10 and 30 (spanning 20 versions)
Revision 10 as of 2020-09-23 14:34:25
Size: 1088
Editor: KousekiMiyo
Comment:
Revision 30 as of 2020-09-23 16:02:52
Size: 1464
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 4: Line 4:
== Flow chart ==
{{https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0120/E2012025/002/VISworkflow-Overview.png|WorkFlow|width=600}}
Line 5: Line 8:
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for A]]
Line 9: Line 14:
=== Templates for the installation phase ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]]
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets templates for B]]
Line 29: Line 33:
 * Please write
  * aaaa
Line 31: Line 37:
 * Please write
  * aaaa
Line 33: Line 41:
 * Please write
  * aaaa
Line 36: Line 45:
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for C]]
Line 37: Line 48:
 * Damping time
  * RMS in spectrum (plot)
 * Healthy check
  * Transfer function (plot)
  * Resonant frequencies (PreQUA)
 * Noise budget
  * Spectrum (plot)
 * Automation
  * check the guardian transition
Line 39: Line 59:


------




== Check items on Software (Control) ==
=== Healthy check template ===
 * Transfer function (plot)
 * Resonant frequencies (PreQUA)

=== Damping time ===
 * RMS in spectrum (plot)

=== Noise budget ===
 * Spectrum (plot)

=== Guardian ===
 * Please write
  * aaaa

Acceptance Test

Flow chart

WorkFlow

A: Design phase

Check sheets templates for A

A01

  • hoge

B: Installation phase

Check sheets templates for B

B01

  • Cable connection
    • Resistance (Ohom)
    • Continuity (OK/NO)
  • Calibration (LVDT, ACC)
    • Calibration (plot, polarity, coefficient)
    • Sensor noise (plot)
  • Working point and dynamic range with FR, Limit SW
    • Range (from -mm to +mm)
    • Minimum range (mm)
    • Optimal point (mm)
    • Limit SW (on/off)
  • Tuned frequencies of GAS Filter/IP
    • Frequency (TF, actuator efficiency)
    • Maximum frequency (Hz)

B02

  • Please write
    • aaaa

B03

  • Please write
    • aaaa

B04

  • Please write
    • aaaa

C: Integration phase

Check sheets templates for C

C01

  • Damping time
    • RMS in spectrum (plot)
  • Healthy check
    • Transfer function (plot)
    • Resonant frequencies (PreQUA)
  • Noise budget
    • Spectrum (plot)
  • Automation
    • check the guardian transition

C02

  • Please write
    • aaaa