1469
Comment:
|
1368
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
{{attachment:VISworkflow-Overview.png}} {{attachment:image.png}} |
== Flow chart == {{https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0120/E2012025/002/VISworkflow-Overview.png|WorkFlow|width=600}} |
Line 10: | Line 8: |
=== Templates for A === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for A]] |
Line 17: | Line 14: |
=== Templates for B === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]] |
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets templates for B]] |
Line 44: | Line 40: |
=== Templates for C === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for C]] |
Line 48: | Line 43: |
* Damping time * RMS in spectrum (plot) |
|
Line 51: | Line 48: |
* Noise budget * Spectrum (plot) * Automation * check the guardian transition |
|
Line 53: | Line 54: |
------ == Check items on Software (Control) == === Healthy check template === * Transfer function (plot) * Resonant frequencies (PreQUA) === Damping time === * RMS in spectrum (plot) === Noise budget === * Spectrum (plot) === Guardian === |
* * |
Contents
Acceptance Test
Flow chart
A: Design phase
A01
- hoge
B: Installation phase
B01
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02
B03
B04
C: Integration phase
C01
- Damping time
- RMS in spectrum (plot)
- Healthy check
- Transfer function (plot)
- Resonant frequencies (PreQUA)
- Noise budget
- Spectrum (plot)
- Automation
- check the guardian transition