1452
Comment:
|
1464
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
{{attachment:VISworkflow-Overview.png|width=50}} |
== Flow chart == {{https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0120/E2012025/003/VISworkflow-Overview.png|WorkFlow|width=600}} |
Line 9: | Line 8: |
=== Templates for A === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for A]] |
Line 16: | Line 14: |
=== Templates for B === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]] |
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets templates for B]] |
Line 36: | Line 33: |
* Please write * aaaa |
|
Line 38: | Line 37: |
* Please write * aaaa |
|
Line 40: | Line 41: |
* Please write * aaaa |
|
Line 43: | Line 45: |
=== Templates for C === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for C]] |
Line 47: | Line 48: |
* Damping time * RMS in spectrum (plot) |
|
Line 50: | Line 53: |
* Noise budget * Spectrum (plot) * Automation * check the guardian transition |
|
Line 52: | Line 59: |
------ == Check items on Software (Control) == === Healthy check template === * Transfer function (plot) * Resonant frequencies (PreQUA) === Damping time === * RMS in spectrum (plot) === Noise budget === * Spectrum (plot) === Guardian === |
* Please write * aaaa |
Contents
Acceptance Test
Flow chart
A: Design phase
A01
- hoge
B: Installation phase
B01
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02
- Please write
- aaaa
B03
- Please write
- aaaa
B04
- Please write
- aaaa
C: Integration phase
C01
- Damping time
- RMS in spectrum (plot)
- Healthy check
- Transfer function (plot)
- Resonant frequencies (PreQUA)
- Noise budget
- Spectrum (plot)
- Automation
- check the guardian transition
C02
- Please write
- aaaa