1790
Comment:
|
1942
|
Deletions are marked like this. | Additions are marked like this. |
Line 13: | Line 13: |
* design sensitivity * DAC limit. |
* Input the design sensitivity * Input the DAC limit |
Line 25: | Line 25: |
* | Transfer function * transfer function of the suspension Noises * requirement for sensor noises * requirement for actuator noises |
Contents
Acceptance Test
Flow chart
A: Design phase
A01 : Could the simulation satisfy the requirement?
Input
KAGRA requirements
- Input the design sensitivity
- Input the DAC limit
Suspension model
- plant model : rigid body model by SUMCON
- control model : LTI model by Matlab simlink
- noise model : seismic noise, control noise
Content
Output
Transfer function
- transfer function of the suspension
Noises
- requirement for sensor noises
- requirement for actuator noises
B: Installation phase
B01
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02
- Please write
- aaaa
B03
- Please write
- aaaa
B04
- Please write
- aaaa
C: Integration phase
C01
- Damping time
- RMS in spectrum (plot)
- Healthy check
- Transfer function (plot)
- Resonant frequencies (PreQUA)
- Noise budget
- Spectrum (plot)
- Automation
- check the guardian transition
C02
- Please write
- aaaa