Differences between revisions 5 and 23 (spanning 18 versions)
Revision 5 as of 2020-09-23 14:24:07
Size: 965
Editor: KousekiMiyo
Comment:
Revision 23 as of 2020-09-23 15:35:22
Size: 1471
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
<<TableOfContents(3)>>
Line 2: Line 4:
== Flow chart ==
{{https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0120/E2012025/001/VISworkflow-Overview.png|ALS Configuration|width=700}}

== A: Design phase ==
=== Templates for A ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]]

=== A01 ===
 * hoge

== B: Installation phase ==
=== Templates for B ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]]

=== B01 ===
 * Cable connection
  * Resistance (Ohom)
  * Continuity (OK/NO)
 * Calibration (LVDT, ACC)
  * Calibration (plot, polarity, coefficient)
  * Sensor noise (plot)
 * Working point and dynamic range with FR, Limit SW
  * Range (from -mm to +mm)
  * Minimum range (mm)
  * Optimal point (mm)
  * Limit SW (on/off)
 * Tuned frequencies of GAS Filter/IP
  * Frequency (TF, actuator efficiency)
  * Maximum frequency (Hz)

=== B02 ===

=== B03 ===

=== B04 ===
Line 4: Line 41:
== (A) Design phase ==
 * A01
== C: Integration phase ==
=== Templates for C ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]]
Line 7: Line 45:
=== C01 ===
 * Damping time
  * RMS in spectrum (plot)
 * Healthy check
  * Transfer function (plot)
  * Resonant frequencies (PreQUA)
Line 8: Line 52:
== (B) Installation phase ==  * Noise budget
  * Spectrum (plot)
Line 10: Line 55:
== (C) Integration phase ==
=== C02 ===
Line 16: Line 60:
== Check items on Hardware ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]]
Line 19: Line 61:
=== Cable connection ===
 * Resistance (Ohom)
 * Continuity (O/X)
Line 23: Line 62:
=== Calibration (LVDT, ACC) ===
 * Calibration (plot, polarity, coefficient)
 * Sensor noise (plot)

=== Working point and dynamic range with FR, Limit SW ===
 * Range (from -mm to +mm)
 * Minimum range (mm)
 * Optimal point (mm)
 * Limit SW (on/off)

=== Tuned frequencies of GAS Filter/IP ===
 * Frequency (TF, actuator efficiency)
 * Maximum frequency (Hz)
Line 38: Line 64:
=== Healthy check template ===
 * Transfer function (plot)
 * Resonant frequencies (PreQUA)

=== Damping time ===
 * RMS in spectrum (plot)

Acceptance Test

Flow chart

ALS Configuration

A: Design phase

Templates for A

Check sheets

A01

  • hoge

B: Installation phase

Templates for B

Check sheets

B01

  • Cable connection
    • Resistance (Ohom)
    • Continuity (OK/NO)
  • Calibration (LVDT, ACC)
    • Calibration (plot, polarity, coefficient)
    • Sensor noise (plot)
  • Working point and dynamic range with FR, Limit SW
    • Range (from -mm to +mm)
    • Minimum range (mm)
    • Optimal point (mm)
    • Limit SW (on/off)
  • Tuned frequencies of GAS Filter/IP
    • Frequency (TF, actuator efficiency)
    • Maximum frequency (Hz)

B02

B03

B04

C: Integration phase

Templates for C

Check sheets

C01

  • Damping time
    • RMS in spectrum (plot)
  • Healthy check
    • Transfer function (plot)
    • Resonant frequencies (PreQUA)
  • Noise budget
    • Spectrum (plot)

C02


Check items on Software (Control)

Noise budget

  • Spectrum (plot)

Guardian

KAGRA/Subgroups/VIS/Acceptance Test (last edited 2020-12-04 11:38:31 by KousekiMiyo)