Differences between revisions 6 and 10 (spanning 4 versions)
Revision 6 as of 2020-09-23 14:25:42
Size: 1089
Editor: KousekiMiyo
Comment:
Revision 10 as of 2020-09-23 14:34:25
Size: 1088
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
<<TableOfContents(3)>>
Line 2: Line 4:


== (A) Design phase ==
=== A01===
== A: Design phase ==
=== A01 ===
Line 8: Line 8:
== B: Installation phase ==
=== Templates for the installation phase ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]]
Line 9: Line 12:
== (B) Installation phase ==
Line 13: Line 15:
  * Continuity (O/X)   * Continuity (OK/NO)
 * Calibration (LVDT, ACC)
  * Calibration (plot, polarity, coefficient)
  * Sensor noise (plot)
 * Working point and dynamic range with FR, Limit SW
  * Range (from -mm to +mm)
  * Minimum range (mm)
  * Optimal point (mm)
  * Limit SW (on/off)
 * Tuned frequencies of GAS Filter/IP
  * Frequency (TF, actuator efficiency)
  * Maximum frequency (Hz)

=== B02 ===

=== B03 ===

=== B04 ===
Line 16: Line 35:
== (C) Integration phase == == C: Integration phase ==
Line 22: Line 41:
------
Line 24: Line 44:
------
Line 26: Line 45:
== Check items on Hardware ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]]

=== Cable connection ===
 * Resistance (Ohom)
 * Continuity (O/X)

=== Calibration (LVDT, ACC) ===
 * Calibration (plot, polarity, coefficient)
 * Sensor noise (plot)

=== Working point and dynamic range with FR, Limit SW ===
 * Range (from -mm to +mm)
 * Minimum range (mm)
 * Optimal point (mm)
 * Limit SW (on/off)

=== Tuned frequencies of GAS Filter/IP ===
 * Frequency (TF, actuator efficiency)
 * Maximum frequency (Hz)

Acceptance Test

A: Design phase

A01

  • hoge

B: Installation phase

Templates for the installation phase

Check sheets

B01

  • Cable connection
    • Resistance (Ohom)
    • Continuity (OK/NO)
  • Calibration (LVDT, ACC)
    • Calibration (plot, polarity, coefficient)
    • Sensor noise (plot)
  • Working point and dynamic range with FR, Limit SW
    • Range (from -mm to +mm)
    • Minimum range (mm)
    • Optimal point (mm)
    • Limit SW (on/off)
  • Tuned frequencies of GAS Filter/IP
    • Frequency (TF, actuator efficiency)
    • Maximum frequency (Hz)

B02

B03

B04

C: Integration phase

C01

C02


Check items on Software (Control)

Healthy check template

  • Transfer function (plot)
  • Resonant frequencies (PreQUA)

Damping time

  • RMS in spectrum (plot)

Noise budget

  • Spectrum (plot)

Guardian