Size: 1089
Comment:
|
Size: 1529
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
<<TableOfContents(3)>> |
|
Line 2: | Line 4: |
== Overview == {{https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0120/E2012025/001/VISworkflow-Overview.png|ALS Configuration|width=700}} |
|
Line 3: | Line 7: |
== A: Design phase == === Templates for A === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
|
Line 4: | Line 11: |
== (A) Design phase == === A01=== |
=== A01 === |
Line 8: | Line 14: |
== B: Installation phase == === Templates for B === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]] |
|
Line 9: | Line 18: |
== (B) Installation phase == | |
Line 13: | Line 21: |
* Continuity (O/X) | * Continuity (OK/NO) * Calibration (LVDT, ACC) * Calibration (plot, polarity, coefficient) * Sensor noise (plot) * Working point and dynamic range with FR, Limit SW * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) * Tuned frequencies of GAS Filter/IP * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) === B02 === === B03 === === B04 === |
Line 16: | Line 41: |
== (C) Integration phase == | == C: Integration phase == === Templates for C === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
Line 18: | Line 46: |
* Healthy check * Transfer function (plot) * Resonant frequencies (PreQUA) |
|
Line 22: | Line 53: |
------ | |
Line 24: | Line 56: |
------ | |
Line 26: | Line 57: |
== Check items on Hardware == [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]] === Cable connection === * Resistance (Ohom) * Continuity (O/X) === Calibration (LVDT, ACC) === * Calibration (plot, polarity, coefficient) * Sensor noise (plot) === Working point and dynamic range with FR, Limit SW === * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) === Tuned frequencies of GAS Filter/IP === * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) |
Contents
Acceptance Test
Overview
A: Design phase
Templates for A
A01
- hoge
B: Installation phase
Templates for B
B01
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02
B03
B04
C: Integration phase
Templates for C
C01
- Healthy check
- Transfer function (plot)
- Resonant frequencies (PreQUA)
C02
Check items on Software (Control)
Healthy check template
- Transfer function (plot)
- Resonant frequencies (PreQUA)
Damping time
- RMS in spectrum (plot)
Noise budget
- Spectrum (plot)