Differences between revisions 6 and 22 (spanning 16 versions)
Revision 6 as of 2020-09-23 14:25:42
Size: 1089
Editor: KousekiMiyo
Comment:
Revision 22 as of 2020-09-23 14:54:41
Size: 1531
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
<<TableOfContents(3)>>
Line 2: Line 4:
== Flow chart ==
{{https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0120/E2012025/001/VISworkflow-Overview.png|ALS Configuration|width=700}}
Line 3: Line 7:
== A: Design phase ==
=== Templates for A ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]]
Line 4: Line 11:
== (A) Design phase ==
=== A01===
=== A01 ===
Line 8: Line 14:
== B: Installation phase ==
=== Templates for B ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]]
Line 9: Line 18:
== (B) Installation phase ==
Line 13: Line 21:
  * Continuity (O/X)   * Continuity (OK/NO)
 * Calibration (LVDT, ACC)
  * Calibration (plot, polarity, coefficient)
  * Sensor noise (plot)
 * Working point and dynamic range with FR, Limit SW
  * Range (from -mm to +mm)
  * Minimum range (mm)
  * Optimal point (mm)
  * Limit SW (on/off)
 * Tuned frequencies of GAS Filter/IP
  * Frequency (TF, actuator efficiency)
  * Maximum frequency (Hz)

=== B02 ===

=== B03 ===

=== B04 ===
Line 16: Line 41:
== (C) Integration phase == == C: Integration phase ==
=== Templates for C ===
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]]
Line 18: Line 46:
 * Healthy check
  * Transfer function (plot)
  * Resonant frequencies (PreQUA)
Line 22: Line 53:
------
Line 24: Line 56:
------
Line 26: Line 57:
== Check items on Hardware ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]]

=== Cable connection ===
 * Resistance (Ohom)
 * Continuity (O/X)

=== Calibration (LVDT, ACC) ===
 * Calibration (plot, polarity, coefficient)
 * Sensor noise (plot)

=== Working point and dynamic range with FR, Limit SW ===
 * Range (from -mm to +mm)
 * Minimum range (mm)
 * Optimal point (mm)
 * Limit SW (on/off)

=== Tuned frequencies of GAS Filter/IP ===
 * Frequency (TF, actuator efficiency)
 * Maximum frequency (Hz)

Acceptance Test

Flow chart

ALS Configuration

A: Design phase

Templates for A

Check sheets

A01

  • hoge

B: Installation phase

Templates for B

Check sheets

B01

  • Cable connection
    • Resistance (Ohom)
    • Continuity (OK/NO)
  • Calibration (LVDT, ACC)
    • Calibration (plot, polarity, coefficient)
    • Sensor noise (plot)
  • Working point and dynamic range with FR, Limit SW
    • Range (from -mm to +mm)
    • Minimum range (mm)
    • Optimal point (mm)
    • Limit SW (on/off)
  • Tuned frequencies of GAS Filter/IP
    • Frequency (TF, actuator efficiency)
    • Maximum frequency (Hz)

B02

B03

B04

C: Integration phase

Templates for C

Check sheets

C01

  • Healthy check
    • Transfer function (plot)
    • Resonant frequencies (PreQUA)

C02


Check items on Software (Control)

Healthy check template

  • Transfer function (plot)
  • Resonant frequencies (PreQUA)

Damping time

  • RMS in spectrum (plot)

Noise budget

  • Spectrum (plot)

Guardian