Differences between revisions 7 and 37 (spanning 30 versions)
Revision 7 as of 2020-09-23 14:27:34
Size: 1087
Editor: KousekiMiyo
Comment:
Revision 37 as of 2020-09-23 17:57:15
Size: 2036
Editor: KousekiMiyo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
<<TableOfContents(3)>>

= Acceptance Test =
== Flow chart ==
{{https://gwdoc.icrr.u-tokyo.ac.jp/DocDB/0120/E2012025/003/VISworkflow-Overview.png|WorkFlow|width=600}}

== A: Design phase ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for A]]

=== A01 : Could the simulation satisfy the requirement? ===
==== Input ====
* KAGRA requirements
 * Input the design sensitivity (ref. xxx)
 * Input the DAC limit (ref. xxx)
* Suspension model
 * plant model : rigid body model by SUMCON (ref. xxx)
 * control model : LTI model by Matlab simlink (ref. xxx)
 * noise model : seismic noise, control noise (ref. xxx)

==== Content ====
Line 3: Line 23:

= Acceptance Test =
== A: Design phase ==
=== A01 ===
 * hoge
==== Output ====
 * Transfer function
  * transfer function of the suspension (ref. xxx)
 * Noises
  * requirement for sensor noises (ref. xxx)
  * requirement for actuator noises (ref. xxx)
Line 10: Line 31:
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets templates for B]]
Line 14: Line 37:
 * Calibration (LVDT, ACC)
  * Calibration (plot, polarity, coefficient)
  * Sensor noise (plot)
 * Working point and dynamic range with FR, Limit SW
  * Range (from -mm to +mm)
  * Minimum range (mm)
  * Optimal point (mm)
  * Limit SW (on/off)
 * Tuned frequencies of GAS Filter/IP
  * Frequency (TF, actuator efficiency)
  * Maximum frequency (Hz)

=== B02 ===
 * Please write
  * aaaa

=== B03 ===
 * Please write
  * aaaa

=== B04 ===
 * Please write
  * aaaa
Line 16: Line 62:
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for C]]
Line 17: Line 65:
 * Damping time
  * RMS in spectrum (plot)
 * Healthy check
  * Transfer function (plot)
  * Resonant frequencies (PreQUA)
 * Noise budget
  * Spectrum (plot)
 * Automation
  * check the guardian transition
Line 19: Line 76:




------

== Check items on Hardware ==
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]]

=== Cable connection ===
 * Resistance (Ohom)
 * Continuity (O/X)

=== Calibration (LVDT, ACC) ===
 * Calibration (plot, polarity, coefficient)
 * Sensor noise (plot)

=== Working point and dynamic range with FR, Limit SW ===
 * Range (from -mm to +mm)
 * Minimum range (mm)
 * Optimal point (mm)
 * Limit SW (on/off)

=== Tuned frequencies of GAS Filter/IP ===
 * Frequency (TF, actuator efficiency)
 * Maximum frequency (Hz)

== Check items on Software (Control) ==
=== Healthy check template ===
 * Transfer function (plot)
 * Resonant frequencies (PreQUA)

=== Damping time ===
 * RMS in spectrum (plot)

=== Noise budget ===
 * Spectrum (plot)

=== Guardian ===
 * Please write
  * aaaa

Acceptance Test

Flow chart

WorkFlow

A: Design phase

Check sheets templates for A

A01 : Could the simulation satisfy the requirement?

Input

* KAGRA requirements

  • Input the design sensitivity (ref. xxx)
  • Input the DAC limit (ref. xxx)

* Suspension model

  • plant model : rigid body model by SUMCON (ref. xxx)
  • control model : LTI model by Matlab simlink (ref. xxx)
  • noise model : seismic noise, control noise (ref. xxx)

Content

Output

  • Transfer function
    • transfer function of the suspension (ref. xxx)
  • Noises
    • requirement for sensor noises (ref. xxx)
    • requirement for actuator noises (ref. xxx)

B: Installation phase

Check sheets templates for B

B01

  • Cable connection
    • Resistance (Ohom)
    • Continuity (OK/NO)
  • Calibration (LVDT, ACC)
    • Calibration (plot, polarity, coefficient)
    • Sensor noise (plot)
  • Working point and dynamic range with FR, Limit SW
    • Range (from -mm to +mm)
    • Minimum range (mm)
    • Optimal point (mm)
    • Limit SW (on/off)
  • Tuned frequencies of GAS Filter/IP
    • Frequency (TF, actuator efficiency)
    • Maximum frequency (Hz)

B02

  • Please write
    • aaaa

B03

  • Please write
    • aaaa

B04

  • Please write
    • aaaa

C: Integration phase

Check sheets templates for C

C01

  • Damping time
    • RMS in spectrum (plot)
  • Healthy check
    • Transfer function (plot)
    • Resonant frequencies (PreQUA)
  • Noise budget
    • Spectrum (plot)
  • Automation
    • check the guardian transition

C02

  • Please write
    • aaaa