Size: 1107
Comment:
|
Size: 1088
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 9: | Line 9: |
=== Templates for the installation phase === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]] |
|
Line 13: | Line 16: |
* Calibration (LVDT, ACC) * Calibration (plot, polarity, coefficient) * Sensor noise (plot) * Working point and dynamic range with FR, Limit SW * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) * Tuned frequencies of GAS Filter/IP * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) === B02 === === B03 === === B04 === |
|
Line 20: | Line 41: |
------ | |
Line 22: | Line 44: |
------ | |
Line 24: | Line 45: |
== Check items on Hardware == [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]] === Cable connection === * Resistance (Ohom) * Continuity (O/X) === Calibration (LVDT, ACC) === * Calibration (plot, polarity, coefficient) * Sensor noise (plot) === Working point and dynamic range with FR, Limit SW === * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) === Tuned frequencies of GAS Filter/IP === * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) |
Contents
Acceptance Test
A: Design phase
A01
- hoge
B: Installation phase
Templates for the installation phase
B01
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02
B03
B04
C: Integration phase
C01
C02
Check items on Software (Control)
Healthy check template
- Transfer function (plot)
- Resonant frequencies (PreQUA)
Damping time
- RMS in spectrum (plot)
Noise budget
- Spectrum (plot)