Size: 1107
Comment:
|
← Revision 49 as of 2020-12-04 11:38:31 ⇥
Size: 1716
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
== Flow chart == [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=12025| Flow chart for the acceptance check ]] |
|
Line 5: | Line 10: |
=== A01 === * hoge |
[[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for A]] === A01 : Simulation satisfy the requirement? === * {i} Please write |
Line 9: | Line 17: |
=== B01 === | [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets templates for B]] === B01 : Tower is ready to combine? === |
Line 13: | Line 23: |
* Calibration (LVDT, ACC) * Calibration (plot, polarity, coefficient) * Sensor noise (plot) * Working point and dynamic range with FR, Limit SW * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) * Tuned frequencies of GAS Filter/IP * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) === B02 : Payload is ready to combine? === * {i} Please write === B03 : Can we measure the TF in air? === * {i} Please write === B04 : Can we measure the TF in vacuum? === * Damping time * RMS in spectrum (plot) * Healthy check * Transfer function (plot) * Resonant frequencies (PreQUA) |
|
Line 15: | Line 49: |
=== C01 === | [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets templates for C]] |
Line 17: | Line 51: |
=== C02 === | === C01 : Can we control the suspension in local? === * Noise budget * Spectrum (plot) * Automation * check the guardian transition |
Line 19: | Line 57: |
------ == Check items on Hardware == [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]] === Cable connection === * Resistance (Ohom) * Continuity (O/X) === Calibration (LVDT, ACC) === * Calibration (plot, polarity, coefficient) * Sensor noise (plot) === Working point and dynamic range with FR, Limit SW === * Range (from -mm to +mm) * Minimum range (mm) * Optimal point (mm) * Limit SW (on/off) === Tuned frequencies of GAS Filter/IP === * Frequency (TF, actuator efficiency) * Maximum frequency (Hz) == Check items on Software (Control) == === Healthy check template === * Transfer function (plot) * Resonant frequencies (PreQUA) === Damping time === * RMS in spectrum (plot) === Noise budget === * Spectrum (plot) === Guardian === |
=== C02 : Can we control the suspension in global? === * Please write * aaaa |
Acceptance Test
Flow chart
Flow chart for the acceptance check
A: Design phase
A01 : Simulation satisfy the requirement?
Please write
B: Installation phase
B01 : Tower is ready to combine?
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02 : Payload is ready to combine?
Please write
B03 : Can we measure the TF in air?
Please write
B04 : Can we measure the TF in vacuum?
- Damping time
- RMS in spectrum (plot)
- Healthy check
- Transfer function (plot)
- Resonant frequencies (PreQUA)
C: Integration phase
C01 : Can we control the suspension in local?
- Noise budget
- Spectrum (plot)
- Automation
- check the guardian transition
C02 : Can we control the suspension in global?
- Please write
- aaaa