1027
Comment:
|
1447
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
{{attachment:VISworkflow-Overview.png]]}} |
|
Line 5: | Line 10: |
=== Templates for A === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
|
Line 9: | Line 17: |
=== Templates for B === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheets]] |
|
Line 25: | Line 36: |
=== B02 === === B03 === === B04 === |
|
Line 26: | Line 44: |
=== Templates for C === [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=xxx|Check sheets]] |
|
Line 27: | Line 48: |
* Healthy check * Transfer function (plot) * Resonant frequencies (PreQUA) |
|
Line 31: | Line 55: |
Line 35: | Line 57: |
== Check items on Hardware == [[https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=11957|Check sheet]] |
Contents
Acceptance Test
A: Design phase
Templates for A
A01
- hoge
B: Installation phase
Templates for B
B01
- Cable connection
- Resistance (Ohom)
- Continuity (OK/NO)
- Calibration (LVDT, ACC)
- Calibration (plot, polarity, coefficient)
- Sensor noise (plot)
- Working point and dynamic range with FR, Limit SW
- Range (from -mm to +mm)
- Minimum range (mm)
- Optimal point (mm)
- Limit SW (on/off)
- Tuned frequencies of GAS Filter/IP
- Frequency (TF, actuator efficiency)
- Maximum frequency (Hz)
B02
B03
B04
C: Integration phase
Templates for C
C01
- Healthy check
- Transfer function (plot)
- Resonant frequencies (PreQUA)
C02
Check items on Software (Control)
Healthy check template
- Transfer function (plot)
- Resonant frequencies (PreQUA)
Damping time
- RMS in spectrum (plot)
Noise budget
- Spectrum (plot)